®SUPERSERVER 6014H-32 USER’S MANUAL1.0 SUPER
SUPERSERVER 6014H-32 User's ManualxNotes
B-8SUPERSERVER 6014H-32 User’s ManualAssigning Array PropertiesOnce you've create a new array, you are ready to assign the properties to the arra
Appendix B: Software InstallationB-93. For RAID 0, select the desired stripe size. (*Note: Available stripe sizesare 16, 32, and 64 KB-default. It is
B-10SUPERSERVER 6014H-32 User’s ManualNotes:1. Before adding a new drive to an array, back up any data contained on the new drive. Otherwise, all data
Appendix B: Software InstallationB-11Adding a Bootable ArrayTo make an array bootable:1. From the Main menu, select Manage Arrays. 2. From the List of
B-12SUPERSERVER 6014H-32 User’s ManualInitializing Disk DrivesIf an installed disk does not appear in the disk selection list for creating a new ar-ra
Appendix B: Software InstallationB-134. Use the up and down arrow keys to select the disk you wish to initialize and press Insert (as shown in the scr
B-14SUPERSERVER 6014H-32 User’s Manual5. Repeat Step 4 so that both drives to be initialized are selected (as shown below). 6. Press Enter.7. Read th
Appendix B: Software InstallationB-15Rebuilding ArraysNote 1: Rebuilding applies to Fault Tolerant array (RAID 1) only.If an array Build process (or i
B-16SUPERSERVER 6014H-32 User’s ManualAdaptec SAS/SATA with HostRAID Controller DriverThe onboard Adaptec AIC9140W SAS Controller supports two ports.
Appendix B: Software InstallationB-17Managing ArraysSelect this option to view array properties, and delete arrays. The following sec-tions describe t
Chapter 1: Introduction1-1Chapter 1 Introduction1-1 OverviewThe Supermicro SuperServer 6014H-32 is a high-end dual processor, 1U rackmount serve
B-18SUPERSERVER 6014H-32 User’s ManualDeleting ArraysWarning: Back up the data on an array before you delete it to prevent the loss of data. Deleted
Appendix B: Software InstallationB-19Assigning Array PropertiesOnce you've create a new array, you are ready to assign the properties to the arra
B-20SUPERSERVER 6014H-32 User’s Manual3. A RAID 1 created using the Quick Init option may return some data mis-com-pares if you later run a consistenc
Appendix B: Software InstallationB-21Initializing Disk DrivesIf an installed disk does not appear in the disk selection list for creating a new array,
B-22SUPERSERVER 6014H-32 User’s ManualUsing the SerialSelect Utility to Confi gure SAS SettingsThe SerialSelect Utility enables you to confi gure SAS di
Appendix B: Software InstallationB-234. Use the arrow keys to select an item. Then, press <Enter> and the arrow keys to confi gure the setting fo
B-24SUPERSERVER 6014H-32 User’s ManualTo Set the Physical Confi guration:1. Turn on the computer and press Ctrl+A when prompted to access the ARC util-
Appendix B: Software InstallationB-25Using the Disk UtilitiesThe Disk Utilities enable you to format or verify the media of your Serial ATA hard disks
B-26SUPERSERVER 6014H-32 User’s ManualTo Exit Adaptec RAID Confi guration Utility1. Once you have completed RAID array confi gurations, press ESC to exi
Appendix B: Software InstallationB-27B-2 Installing the 6300ESB/SAS Driver and the OS a. Insert Supermicro's bootable CD that came with the pack
SUPERSERVER 6014H-32 User's Manual1-21-2 Serverboard FeaturesAt the heart of the SuperServer 6014H-32 lies the X6DHR-3G2 a dual Xeon pro-cessor s
B-28SUPERSERVER 6014H-32 User’s ManualDriver/Tool Installation Display ScreenNote: Click the icons showing a hand writing on paper to view the readme
Appendix B: Software InstallationB-29Supero Doctor IIIThe Supero Doctor III program is a Web base management tool that supports remote management capa
B-30SUPERSERVER 6014H-32 User’s ManualSupero Doctor III Interface Display Screen-II (Remote Control)Notes: 1. SD III Software Revision 1.0 can be dow
C-1Appendix C: System Specifi cationsAppendix DSystem Specifi cationsProcessors Single or dual Intel® Xeon™ 604-pin processors to 3.60 GHz at a fr
C-2SUPERSERVER 6014H-32 User's ManualExpansion Slots (provided with included riser cards) One (1) 64-bit 133 MHz standard size PCI-X slot and
C-3Appendix C: System Specifi cationsRegulatory Compliance Electromagnetic Emissions: FCC Class B, EN 55022 Class B, EN 61000-3-2/-3-3, CISPR
C-4SUPERSERVER 6014H-32 User's ManualNotes
Chapter 1: Introduction1-3ATI Graphics ControllerAn ATI video controller based on the Rage XL 8 MB graphics chip is integrated onboard the X6DHR-3G2.
SUPERSERVER 6014H-32 User's Manual1-41-3 Server Chassis FeaturesThe SC813T-500 is one of Supermicro's third-generation 1U chassis and featur
Chapter 1: Introduction1-5Figure 1-1. Intel E7520 Chipset: System Block Diagram Note: This is a general block diagram. Please see Chapter 5 for deta
SUPERSERVER 6014H-32 User's Manual1-61-4 Contacting SupermicroHeadquarters Address: SuperMicro Computer, Inc. 980 Rock A
Chapter 2: Server Installation2-1 Chapter 2 Server Installation 2-1 OverviewThis chapter provides a quick setup
2-2SUPERSERVER 6014H-32 User's ManualChoosing a Setup Location - Leave enough clearance in front of the rack to enable you to open the front
Chapter 2: Server Installation2-3Rack Mounting ConsiderationsAmbient Operating TemperatureIf installed in a closed or multi-unit rack assembly, the am
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccu
2-4SUPERSERVER 6014H-32 User's ManualInstalling the Rack RailsBegin by joining one set of rack rails corresponding to either the left or the righ
Chapter 2: Server Installation2-5Installing the Chassis RailsTwo of the chassis rails (Chassis Rail 1) should have already been preattached - one to e
2-6SUPERSERVER 6014H-32 User's ManualFigure 2-3. Installing the Server into a RackInstalling the Server into the RackYou should now have rails a
Chapter 2: Server Installation2-7Figure 2-4. Installing the Server into a Telco RackInstalling the Server into a Telco RackIf you are installing the
2-8SUPERSERVER 6014H-32 User's Manual2-5 Checking the Serverboard SetupAfter you install the 6014H-32 in the rack, you will need to open the uni
Chapter 2: Server Installation2-9Figure 2-5. Accessing the Inside of the SuperServer 6014H-32 (with optional front bezel shown)2-6 Checking the Driv
2-10SUPERSERVER 6014H-32 User's Manual4. Check the airfl ow Airfl ow is provided by two heavy duty 10-cm blower fans. The system compo-nent
Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are several LEDs on the control panel as well as others on the SAS/SA
3-2SUPERSERVER 6014H-32 User's Manual3-3 Control Panel LEDsThe control panel located on the front of th SC813T-500 chassis has fi ve LEDs. These
Chapter 3: System Interface3-3 HDD: Indicates IDE channel activity. On the SuperServer 6014H-32 this light indicates SAS/SATA and/or CD-ROM drive
PrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It pro-vides information for the installation
3-4SUPERSERVER 6014H-32 User's ManualNotes
Chapter 4: System Safety4-1 Chapter 4 System Safety!Basic electrical safety precautions should be followed to protect yourself from
SUPERSERVER 6014H-32 User's Manual4-24-2 General Safety PrecautionsFollow these rules to ensure general safety: Keep the area around the Super
Chapter 4: System Safety4-34-3 ESD PrecautionsElectrostatic discharge (ESD) is generated by two objects with different electrical charges coming into
SUPERSERVER 6014H-32 User's Manual4-44-4 Operating Precautions Care must be taken to assure that the chassis cover is in place when the
Chapter 5: Advanced Serverboard Setup5-1 Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to install pro
5-2SUPERSERVER 6014H-32 User’s Manual4. To install the heatsink (optional), do not apply any thermal compound to the heatsink or CPU die - the proper
Chapter 5: Advanced Serverboard Setup5-3Figure 5-1. 604-pin PGA Socket: Empty and with Processor InstalledWarning! Make sure you lift the lever com
5-4SUPERSERVER 6014H-32 User’s Manual5-3 Connecting CablesNow that the processors are installed, the next step is to connect the cables to the server
Chapter 5: Advanced Serverboard Setup5-5Figure 5-3. Front Control Panel Header Pins (JF1)Connecting the Control PanelJF1 contains header pins for vari
SUPERSERVER 6014H-32 User's ManualivChapter 4: System SafetyYou should thoroughly familiarize yourself with this chapter for a general overview
5-6SUPERSERVER 6014H-32 User’s Manual5-4 I/O PortsThe I/O ports are color coded in conformance with the PC 99 specifi cation. See Figure 5-4 below for
Chapter 5: Advanced Serverboard Setup5-7Figure 5-5b. Top View of DDR Slot Figure 5-5a. Installing DIMM into SlotMemory SupportThe X6DHR-3G2 supports
5-8SUPERSERVER 6014H-32 User’s Manual5-6 Adding PCI Cards1. PCI slots The 6014H-32 can accommodate add-on cards in both the PCI-X 133 MHz and t
Chapter 5: Advanced Serverboard Setup5-9DIMM 4BUSB 0/1COM1DIMM 4ADIMM 3BDIMM 3ADIMM 2BDIMM 2ADIMM 1BDIMM 1AJLAN1JLAN2VGABattery RAGEXLPXHSlot 6: PCI-
5-10SUPERSERVER 6014H-32 User’s ManualX6DHR-3G2 Quick ReferenceJumper Description Default SettingJ3P 3rd Power Supply Detect Open (Disabled
Chapter 5: Advanced Serverboard Setup5-115-8 Connector Defi nitions Power LED The Power LED connection is located on pins 15 and 16 of JF1. Refer to t
5-12SUPERSERVER 6014H-32 User’s ManualOverheat/Fan Fail LED (OH)Connect an LED to the OH connection on pins 7 and 8 of JF1 to provide ad-vanced warnin
Chapter 5: Advanced Serverboard Setup5-13Reset Button The Reset Button connection is lo-cated on pins 3 and 4 of JF1. Attach it to the hardware reset
5-14SUPERSERVER 6014H-32 User’s ManualFan HeadersThe X6DHR-3G2 has fi ve fan head-ers, designated Fan1 through Fan5. Fan speed is controlled via Therm
Chapter 5: Advanced Serverboard Setup5-15ATX PS/2 Keyboard and PS/2 Mouse PortsThe ATX PS/2 keyboard and the PS/2 mouse ports are located at J33 and J
vPrefaceNotes
5-16SUPERSERVER 6014H-32 User’s ManualWake-On-LANThe Wake-On-LAN header is desig-nated WOL. See the table on the right for pin defi nitions. You must
Chapter 5: Advanced Serverboard Setup5-175-9 Jumper SettingsExplanation of JumpersTo modify the operation of the serverboard, jumpers can be used
5-18SUPERSERVER 6014H-32 User’s ManualJLAN Enable/Disable Change the setting of jumper JPL1 to enable or disable the JLAN1 and JLAN2 Ethernet ports.
Chapter 5: Advanced Serverboard Setup5-19Watch Dog Enable/DisableJWD controls the Watch Dog function. Watch Dog is a system monitor that can reboot t
5-20SUPERSERVER 6014H-32 User’s Manual5-10 Onboard IndicatorsJLAN1/JLAN2 LEDsThe Ethernet ports (located beside the VGA port) have two LEDs. On each
Chapter 5: Advanced Serverboard Setup5-215-11 SATA, Floppy and Hard Drive ConnectionsNote the following when connecting the fl oppy and hard disk driv
5-22SUPERSERVER 6014H-32 User’s ManualSATA ConnectorsSee the table on the right for pin defi nitions for the onboard SATA connectors.SATA Connector Pin
Chapter 6: Advanced Chassis Setup6-1Chapter 6Advanced Chassis Setup This chapter covers the steps required to install components and perform m
6-2SUPERSERVER 6014H-32 User's ManualFigure 6-1. Chassis: Front and Rear ViewsSystem Reset6-2 Control PanelThe control panel (located on the fro
Chapter 6: Advanced Chassis Setup6-36-3 System FansTwo 10-cm blower fans provide all the cooling needed for the SuperServer 6014H-32. It is very impo
SUPERSERVER 6014H-32 User's ManualviTable of ContentsPrefaceAbout This Manual ...
6-4SUPERSERVER 6014H-32 User's ManualFigure 6-2. System Cooling Fans (with optional front bezel shown)6-4 Drive Bay Installation/RemovalRemoving
Chapter 6: Advanced Chassis Setup6-5Accessing the Drive BaysSAS/SATA Drives: Because of their hotswap capability, you do not need to access the inside
6-6SUPERSERVER 6014H-32 User's ManualSAS/SATA Drive Installation1. Mounting a SAS/SATA drive in a drive carrier The SAS/SATA drives are mounte
Chapter 6: Advanced Chassis Setup6-72. Installing/removing hot-swap SAS/SATA drivesThe SAS/SATA drive carriers are all easily accessible at the front
6-8SUPERSERVER 6014H-32 User's ManualCD-ROM and Floppy Drive InstallationThe top cover of the chassis must be opened to gain full access to the C
Chapter 6: Advanced Chassis Setup6-96-5 Power SupplyThe SuperServer 6014H-32 has a single 500 watt power supply, which is auto-switching capable. Thi
6-10SUPERSERVER 6014H-32 User's ManualFigure 6-6. Removing/Replacing the Power Supply
Chapter 7: BIOS7-1Chapter 7 BIOS7-1 IntroductionThis chapter describes the Phoenix BIOS™ Setup utility for the X6DHR-3G2. The Phoenix ROM BIOS
7-2SUPERSERVER 6014H-32 User's Manual7-2 Running Setup*Default settings are in bold text unless otherwise noted.The BIOS setup options described
Chapter 7: BIOS7-3Main BIOS Setup MenuMain Setup FeaturesSystem TimeTo set the system date and time, key in the correct information in the appropriate
Power ... 3-33-4 SAS/SATA Drive Carrier LED ...
7-4SUPERSERVER 6014H-32 User's ManualLegacy Diskette AThis setting allows the user to set the type of fl oppy disk drive installed as diskette A.
Chapter 7: BIOS7-5Multi-Sector TransfersSelect the number of transfer sectors. The options are Disabled, 2, 4, 6, 8 and 16 Sectors. LBA Mode Control
7-6SUPERSERVER 6014H-32 User's Manual7-4 Advanced Setup Choose Advanced from the Phoenix BIOS Setup Utility main menu with the arrow keys. You s
Chapter 7: BIOS7-7Power Button Behavior If set to Instant-Off, the system will power off immediately as soon as the user hits the power button. If set
7-8SUPERSERVER 6014H-32 User's Manual Cache Base 0-512KIf enabled, this feature will allow the data stored in the base memory area: block 0-512K
Chapter 7: BIOS7-9PCI Confi gurationAccess the submenu to make changes to the following settings for PCI devices.Onboard GLAN (Gigabit- LAN) OPROM Con
7-10SUPERSERVER 6014H-32 User's ManualEnable MasterThis setting allows you to enable the selected device as the PCI bus master. The options are
Chapter 7: BIOS7-11ECC Error TypeThis setting lets you select which type of interrupt to be activated as a result of an ECC error. The options are No
7-12SUPERSERVER 6014H-32 User's ManualNo Execute Mode Memory Protection (*Available when supported by the CPU.)Enable this feature to enable the
Chapter 7: BIOS7-13I/O Device Confi gurationAccess the submenu to make changes to the following settings. KBC Clock InputThis setting allows you to se
SUPERSERVER 6014H-32 User's ManualviiiExtra USB Headers ... 5-15Po
7-14SUPERSERVER 6014H-32 User's ManualDMI Event LoggingAccess the submenu to make changes to the following settings. Event Log ValidityThis is a
Chapter 7: BIOS7-15Console ConnectionSelect the console connection: either Direct or Via Modem. Continue CR after POSTThis option allows the user to d
7-16SUPERSERVER 6014H-32 User's Manual7-5 SecurityChoose Security from the Phoenix BIOS Setup Utility main menu with the arrow keys. You should
Chapter 7: BIOS7-17Set User PasswordWhen the item "Set User Password" is highlighted, hit the <Enter> key. When prompted, type the u
7-18SUPERSERVER 6014H-32 User's Manual+Removable DevicesHighlight and press <Enter> to expand the fi eld. See details on how to change the
Chapter 7: BIOS7-19Exit Saving ChangesHighlight this item and hit <Enter> to save any changes you made and to exit the BIOS Setup utility.Exit D
7-20SUPERSERVER 6014H-32 User's ManualNotes
Appendix A: BIOS POST CodesA-1This section lists the POST (Power On Self Test) codes for the PhoenixBIOS. POST codes are divided into two categories:
A-2SUPERSERVER 6014H-32 User’s ManualPOST Code Description18h 8254 timer initialization1Ah 8237 DMA controller initialization1Ch Reset Pro
Appendix A: BIOS POST CodesA-3POST Code Description5Ch Test RAM between 512 and 640 kB60h Test extended memory62h Test extended memory a
Table of ContentsixRemoving/Replacing the Power Supply ... 6-9Chapter 7: BIOS 7-1 Introduction ...
A-4SUPERSERVER 6014H-32 User’s ManualPOST Code Description99h Check for SMART Drive (optional)9Ah Shadow option ROMs9Ch Set up Power Man
Appendix A: BIOS POST CodesA-5POST Code DescriptionCDh Re-map I/O and memory for PCMCIACEh Initialize digitizer and display messageD2h U
A-6SUPERSERVER 6014H-32 User’s ManualNotes
Appendix B: Software InstallationB-1 Appendix BSoftware InstallationB-1 Introduction to the Adaptec SATA RAID Controller Serial ATA (SATA)Serial AT
B-2SUPERSERVER 6014H-32 User’s ManualPrimary Master(=PM) Yes Yes No No No NoPrimary Slave(=PS) Yes No Yes No No NoSecondary Master(=SM) Yes No No Yes
Appendix B: Software InstallationB-3Confi guring BIOS settings for the SATA RAID Functions (Enhanced Mode)1. Press the <Del> key during system b
B-4SUPERSERVER 6014H-32 User’s ManualAdaptec SATA with HostRAID Controller DriverAdaptec's Embedded Serial ATA RAID with HostRAID controller adds
Appendix B: Software InstallationB-5Managing ArraysSelect this option to view array properties, and delete arrays. The following sec-tions describe th
B-6SUPERSERVER 6014H-32 User’s ManualViewing Array PropertiesTo view the properties of an existing array:1. At the BIOS prompt, press Ctrl+A.2. From t
Appendix B: Software InstallationB-7Creating ArraysBefore creating arrays, make sure the disks for the array are connected and installed in your syste