Supermicro 5038D-I Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Barebone serveru Supermicro 5038D-I. Supermicro 5038D-I Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 114
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků

Shrnutí obsahu

Strany 1 - SUPER

SUPERSERVER5038D-i SUPER®USER’S MANUAL1.0a

Strany 2 - Release Date: March 4, 2014

1-2SUPERSERVER 5038D-i User's Manual1-2 Motherboard FeaturesAt the heart of the SuperServer 5038D-i lies the X10SLL-F, a single processor motherb

Strany 3 - Manual Organization

7-24SUPERSERVER 5038D-i User's ManualSMBIOS Event Long Standard SettingsLog System Boot EventThis option toggles the System Boot Event logging to

Strany 4

Chapter 7: BIOS7-25IPMIThe following IPMI information will be displayed:• IPMI Firmware Revision• IPMI StatusSystem Event LogThis feature is used to

Strany 5

7-26SUPERSERVER 5038D-i User's ManualBMC Network Confi gurationLAN Channel 1: This feature allows the user to confi gure the settings for LAN1 Por

Strany 6 - Table of Contents

Chapter 7: BIOS7-277-5 Boot SettingsUse this feature to confi gure Boot Settings:Set Boot PriorityThis option prioritizes the order of bootable devices

Strany 7

7-28SUPERSERVER 5038D-i User's ManualDelete Boot OptionThis feature allows the user to delete a previously defi ned boot device from which the s

Strany 8 - Chapter 7 BIOS

Chapter 7: BIOS7-297-6 Security SettingsThis menu allows the user to confi gure the following security settings for the system.• If the Administrator

Strany 9 - Introduction

7-30SUPERSERVER 5038D-i User's Manual7-7 Save & ExitSelect the Exit tab from the BIOS Setup Utility screen to enter the Exit BIOS Setup scre

Strany 10 - 1-2 Motherboard Features

Chapter 7: BIOS7-31Restore Optimized DefaultsTo set this feature, select Restore Defaults from the Exit menu and press <Enter>. These are factor

Strany 11 - 1-3 Chassis Features

7-32SUPERSERVER 5038D-i User's ManualNotes

Strany 12 - System Block Diagram

Appendix A: BIOS Error Beep CodesA-1BIOS Error Beep CodesBeep Code/LED Error Message Description1 beep Refresh Circuits have been reset. (Ready to pow

Strany 13 - 1-4 Contacting Supermicro

1-3Chapter 1: Introduction1-3 Chassis FeaturesThe SC731i-300B is a mini-tower chassis with a unique design that allows most confi gurations to be perfo

Strany 14

A-2SUPERSERVER 5038D-i User's ManualNotes

Strany 15 - System Setup

B-1Appendix B: System Specifi cationsAppendix B System Specifi cationsProcessorsSingle Intel® Xeon® E3-1200 v3 or 4th Gen Core™ i3 processor in an LGA11

Strany 16 - Release Tab

B-2SUPERSERVER 5038D-i User's ManualChassisSC731i-300B (Mini-tower)Dimensions: (WxHxD) 7.25 x 14.25 x 16.75 in. (184 x 362 x 425 mm)WeightGross (

Strany 17 - System Interface

B-3Appendix B: System Specifi cationsDisclaimer (continued from front)The products sold by Supermicro are not intended for and will not be used in life

Strany 18 - Power On

B-4SUPERSERVER 5038D-i User's ManualNotes

Strany 19 - Chapter 4

1-4SUPERSERVER 5038D-i User's ManualFigure 1-1. Intel C222 Chipset: System Block DiagramNote: This is a general block diagram. Please see Chapte

Strany 20

1-5Chapter 1: Introduction1-4 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131 U.S.A.Tel: +1 (408)

Strany 21 - ﺔﻴﺋﺎﺑﺮﻬﻜﻟﺍ

1-6SUPERSERVER 5038D-i User's ManualNotes

Strany 22 - Installation Instructions

Chapter 2: System Setup2-1Chapter 2 System Setup2-1 OverviewThis chapter provides a quick setup checklist to get your SuperServer 5038D-i up and runni

Strany 23 - Circuit Breaker

2-2SUPERSERVER 5038D-i User's ManualFigure 2-1. Accessing the Inside of the 5038D-i13Release TabHandle

Strany 24 - Power Disconnection Warning

Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are four LEDs on the control panel to keep you constantly informed of the ov

Strany 25 - ילמשח קותינ ינפמ הרהזא

3-2SUPERSERVER 5038D-i User's ManualNICIndicates network activity on the Gigabit LAN port when fl ashing.Overheat/Fan FailWhen this LED fl ashes it

Strany 26 - Equipment Installation

4-1Chapter 4: Warning Statements for AC SystemsChapter 4Standardized Warning Statements for AC Systems4-1 About Standardized Warning StatementsThe fo

Strany 27 - Restricted Area

The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccur

Strany 28 - Battery Handling

4-2SUPERSERVER 5038D-i User's ManualWarnung WICHTIGE SICHERHEITSHINWEISEDieses Warnsymbol bedeutet Gefahr. Sie befi nden sich in einer Situation,

Strany 29

4-3Warning Statements for AC Systems안전을 위한 주의사항경고!이 경고 기호는 위험이 있음을 알려 줍니다. 작업자의 신체에 부상을 야기 할 수 있는 상태에 있게 됩니다. 모든 장비에 대한 작업을 수행하기 전에 전기회로와 관련된 위험요소들을 확

Strany 30 - Redundant Power Supplies

4-4SUPERSERVER 5038D-i User's ManualInstallation Instructions Warning!Read the installation instructions before connecting the system to the powe

Strany 31 - Backplane Voltage

4-5Chapter 4: Warning Statements for AC SystemsCircuit Breaker Warning!This product relies on the building's installation for short-circuit (over

Strany 32

4-6SUPERSERVER 5038D-i User's ManualPower Disconnection Warning 電源切断の警告システムコンポーネントの取り付けまたは取り外しのために、シャーシー内部にアクセスするには、システムの電源はすべてのソースから切断され、電源コードは電

Strany 33 - Product Disposal

4-7Chapter 4: Warning Statements for AC Systems¡Advertencia! El sistema debe ser disconnected de todas las fuentes de energía y del cable eléctrico qu

Strany 34 - רצומה קוליס

4-8SUPERSERVER 5038D-i User's ManualEquipment Installation機器の設置トレーニングを受け認定された人だけがこの装置の設置、交換、またはサービスを許可されています。 Warning!Only trained and qualifi ed

Strany 35

4-9Chapter 4: Warning Statements for AC Systemsアクセス制限区域このユ ニットは、アクセス制限区域に設置されることを想定しています。アクセス制限区域は、特別なツール、鍵と錠前、その他のセキュリティの手段を用いてのみ出入りが可能です。 Warning!Th

Strany 36 - Power Cable and AC Adapter

4-10SUPERSERVER 5038D-i User's ManualBattery Handling Warning!There is the danger of explosion if the battery is replaced incorrectly. Replace th

Strany 37 - (UL/CSA ﻞﻤﺤﺗ ﻲﺘﻟﺍﺔﻣﻼﻋ )

4-11Chapter 4: Warning Statements for AC SystemsWarnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die Batterie nur

Strany 38

iiiPrefacePrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the insta

Strany 39 - Advanced Motherboard Setup

4-12SUPERSERVER 5038D-i User's ManualWarnung Dieses Gerät kann mehr als eine Stromzufuhr haben. Um sicherzustellen, dass der Einheit kein trom zu

Strany 40

4-13Chapter 4: Warning Statements for AC SystemsBackplane Voltageバックプレーンの電圧システムの稼働中は危険な電圧または電力が、バックプレーン上にかかっています。修理する際には注意ください。警告当系统正在进行时,背板上有很危险的电压或能

Strany 41 - CPU Pin 1

4-14SUPERSERVER 5038D-i User's ManualComply with Local and National Electrical Codes Warning!Installation of the equipment must comply with local

Strany 42 - Installing the Heatsink

4-15Chapter 4: Warning Statements for AC SystemsProduct Disposal Warning!Ultimate disposal of this product should be handled according to all national

Strany 43 - Removing the Heatsink

4-16SUPERSERVER 5038D-i User's ManualWaarschuwing De uiteindelijke verwijdering van dit product dient te geschieden in overeenstemming met alle n

Strany 44 - 5-3 Connecting Cables

4-17Chapter 4: Warning Statements for AC SystemsWarnungDie Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halt

Strany 45 - 5-4 I/O Ports

4-18SUPERSERVER 5038D-i User's Manual Warning!When installing the product, use the provided or designated connection cables, power cables and AC

Strany 46 - 5-5 Installing Memory

4-19Chapter 4: Warning Statements for AC SystemsAttention Lors de l'installation du produit, utilisez les bables de connection fournis ou désigné

Strany 47

4-20SUPERSERVER 5038D-i User's ManualNotes

Strany 48

Chapter 5: Advanced Motherboard Setup5-1Chapter 5 Advanced Motherboard SetupThis chapter covers the steps required to install processors and heatsinks

Strany 49 - 5-6 Adding PCI Cards

SUPERSERVER 5038D-i User's ManualivChapter 5: Advanced Serverboard SetupChapter 5 provides detailed information on the X10SLL-F serverboard, inc

Strany 50 - 5-7 Motherboard Details

5-2SUPERSERVER 5038D-i User's Manual5-2 Processor and Heatsink InstallationNotes: • Always connect the power cord last and always remove it befo

Strany 51

Chapter 5: Advanced Motherboard Setup5-35. Align the CPU key, which is a semi-circle cutout, against the socket key, which is the notch below the gol

Strany 52 - 5-8 Connector Defi nitions

5-4SUPERSERVER 5038D-i User's ManualThermal GreaseHeatsink FinsInstalling the Heatsink1. Locate the CPU Fan power connec-tor on the motherboard.

Strany 53

Chapter 5: Advanced Motherboard Setup5-58. Repeat Step 7 to insert all four heatsink fasteners into the mounting holes.9. Once all four fasteners ar

Strany 54

5-6SUPERSERVER 5038D-i User's Manual5-3 Connecting CablesNow that the processors are installed, the next step is to connect the cables to the mot

Strany 55

Chapter 5: Advanced Motherboard Setup5-7Figure 5-1. Front Control Panel Header Pins (JF1)5-4 I/O PortsThe I/O ports on the motherboard are located at

Strany 56

5-8SUPERSERVER 5038D-i User's Manual5-5 Installing MemoryNote: Check the Supermicro web site for recommended memory modules.CAUTIONExercise extre

Strany 57

Chapter 5: Advanced Motherboard Setup5-9Populating these DIMM modules with a pair of memory modules of the same type and same size will result in inte

Strany 58 - 5-9 Jumper Settings

5-10SUPERSERVER 5038D-i User's ManualPossible System Memory Allocation & AvailabilitySystem Device SizePhysical Memory Remaining (-Available)

Strany 59

Chapter 5: Advanced Motherboard Setup5-115-6 Adding PCI CardsPCI Expansion SlotsThree standard size PCI expansion (add-on) cards may be added to the

Strany 60

vPrefaceNotes

Strany 61 - 5-10 Onboard Indicators

5-12SUPERSERVER 5038D-i User's ManualFigure 5-4. SUPER X10SLL-F Layout5-7 Motherboard DetailsFAN2JP9SW1T-SGPIO1JSTBY1JIPMB1JPW2JSD1LED3LED2JD1LE

Strany 62 - 5-11 SATA Drive Connections

Chapter 5: Advanced Motherboard Setup5-13USB 4/5, 6/7 (2.0) Backpanel USB 2.0 Ports 4/5, 6/7USB 8/9 Front Panel Accessible USB 2.0 Headers 8/9VGA Back

Strany 63 - 5-12 Installing Software

5-14SUPERSERVER 5038D-i User's Manual5-8 Connector Defi nitions Processor PowerPin Defi nitions (JPW2)Pins Defi nition 1/2 Groun

Strany 64 - SuperDoctor® 5

Chapter 5: Advanced Motherboard Setup5-15NIC1/NIC2 (LAN1/LAN2)The NIC (Network Interface Controller) LED connection for LAN port 1 is located on pins

Strany 65 - 5-13 Onboard Battery

5-16SUPERSERVER 5038D-i User's ManualPower Button The Power Button connection is located on pins 1 and 2 of JF1. Momentarily contacting both pins

Strany 66

Chapter 5: Advanced Motherboard Setup5-17Fan HeaderPin Defi nitions Pin# Defi nition 1 Ground (Black)2 +12V (Red)3 Tachometer4 PWM_ControlFan He

Strany 67 - Advanced Chassis Setup

5-18SUPERSERVER 5038D-i User's ManualPower Supply I2C ConnectorThe Power Supply (I2C) connector is located at JPI2C on the motherboard. This conn

Strany 68 - 6-2 Front Control Panel

Chapter 5: Advanced Motherboard Setup5-19DOM PWR ConnectorThe Disk-On-Module (DOM) power con-nector, located at JSD1, provides 5V (Gen1/Gen) power to

Strany 69 - Power Supply

5-20SUPERSERVER 5038D-i User's Manual5-9 Jumper SettingsExplanation of JumpersTo modify the operation of the mother-board, jumpers can be used to

Strany 70 - 6-3 Front Bezel

Chapter 5: Advanced Motherboard Setup5-21LAN Port Enable/DisableUse JPL1/JPL2 to enable or disable LAN Ports 1 and 2 on the motherboard. See the table

Strany 71

viTable of ContentsChapter 1 Introduction1-1 Overview ...

Strany 72 - 6-5 System Fans

5-22SUPERSERVER 5038D-i User's ManualManagement Engine (ME) Recovery Use Jumper JPME1 to select ME Firmware Recovery mode, which will limit resou

Strany 73 - 6-6 Drive Bay Installation

Chapter 5: Advanced Motherboard Setup5-235-10 Onboard IndicatorsLAN1/LAN2 LEDsThe Ethernet ports (located beside the VGA port) have two LEDs. On each

Strany 74 - Release Tabs

5-24SUPERSERVER 5038D-i User's Manual5-11 SATA Drive ConnectionsSATA Port Pin Defi nitionsPin # Defi nition 1 Ground2 TXP3 TXN4 Gr

Strany 75 - Rail (A)

Chapter 5: Advanced Motherboard Setup5-255-12 Installing SoftwareThe Supermicro ftp site contains drivers and utilities for your system at ftp://ftp.s

Strany 76 - 6-7 Power Supply

5-26SUPERSERVER 5038D-i User's ManualSuperDoctor® 5The Supermicro SuperDoctor 5 is a program that functions in a command-line or web-based interf

Strany 77 - Chapter 7

Chapter 5: Advanced Motherboard Setup5-275-13 Onboard BatteryPlease handle used batteries carefully. Do not damage the battery in any way; a damaged b

Strany 78 - 7-2 Main Setup

5-28SUPERSERVER 5038D-i User's ManualNotes

Strany 79

Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform simple ma

Strany 80 - Boot Feature

6-2SUPERSERVER 5038D-i User's Manual6-2 Front Control PanelThe front control panel must be connected to the JF1 connector on the motherboard to

Strany 81 - Power Confi guration

Chapter 6: Advanced Chassis Setup6-3Figure 6-2. Chassis Rear ViewPCI Expansion SlotsI/O Backplane (see Figure 5-2)Power Supply

Strany 82 - CPU Confi guration

viiTable of ContentsRedundant Power Supplies ... 4-12Backplane Voltage ...

Strany 83

6-4SUPERSERVER 5038D-i User's Manual6-3 Front BezelA bezel may be installed to cover the front of the chassis. Front Bezel Installation1. Remove

Strany 84

Chapter 6: Advanced Chassis Setup6-56-4 Removing the Chassis CoverThe left side cover of the chassis must be removed before replacing the system fan

Strany 85

6-6SUPERSERVER 5038D-i User's ManualFigure 6-5. Replacing the System Fan6-5 System FansThe SC731 includes a super quiet system fan that provides

Strany 86

Chapter 6: Advanced Chassis Setup6-76-6 Drive Bay InstallationThe SC731 chassis must be powered-down before hard drives can be removed from the hard

Strany 87 - • VT-d Capability

6-8SUPERSERVER 5038D-i User's ManualFigure 6-6. Rotating the Hard Drive CageRelease Tab (A)HDD Cage (B)Figure 6-7. Removing a Hard Drive Carrie

Strany 88 - Memory Confi guration

Chapter 6: Advanced Chassis Setup6-9Installing Drives in the Optional Drive BaysThe SC731 chassis has two empty drive bays that support optional devic

Strany 89 - PCH-IO Confi guration

6-10SUPERSERVER 5038D-i User's Manual6-7 Power SupplyThe SC731 chassis includes a 300-watt power supply. The power supply has the ca-pability to

Strany 90

Chapter 7: BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the AMI BIOS Setup Utility for the X10SLM-F/X10SLL-F/X10SLL-SF/X10SLL-S . Th

Strany 91 - • Software Preserve Support

7-2SUPERSERVER 5038D-i User's ManualHow to Start the Setup UtilityNormally, the only visible Power-On Self-Test (POST) routine is the memory test

Strany 92

Chapter 7: BIOS7-3The following Main menu items will be displayed:System Time/System Date Use this option to change the system time and date. Highligh

Strany 93

viiiSUPERSERVER 5038D-i User's ManualFan Failure ...

Strany 94 - ACPI Settings

7-4SUPERSERVER 5038D-i User's Manual7-3 Advanced Setup Confi gurationsUse the arrow keys to select Boot Setup and press <Enter> to access

Strany 95 - Super IO Confi guration

Chapter 7: BIOS7-5Bootup Num-LockThis feature selects the Power-on state for the Numlock key. The options are Off and On.Wait For 'F1' If Er

Strany 96 - Console Redirection Settings

7-6SUPERSERVER 5038D-i User's ManualCPU Confi gurationThe following CPU information will be displayed:• Type of CPU• CPU Signature• Microcode Pat

Strany 97

Chapter 7: BIOS7-7Hyper-threadingSelect Enabled to support Intel Hyper-threading Technology to enhance CPU per-formance. The options are Enabled and D

Strany 98

7-8SUPERSERVER 5038D-i User's ManualCPU AESSelect Enable to enable Intel CPU Advanced Encryption Standard (AES) Instruc-tions for CPU to enhance

Strany 99 - 7-4 Event Logs

Chapter 7: BIOS7-91-Core Ratio Limit (Available when "Turbo Mode" is set to Enabled)This increases (multiplies) 1 clock speed in the CPU cor

Strany 100 - View SMBIOS Event Log

7-10SUPERSERVER 5038D-i User's ManualCPU C3 Report (Available when "CPU C-States" is set to Enabled)Select Enabled to allow the BIOS to

Strany 101 - • IPMI Status

Chapter 7: BIOS7-11LakeTiny FeatureSelect Enabled for LakeTing feature support. The options are Disabled and En-abled.ACPI T StateSelect Enabled for A

Strany 102 - BMC Network Confi guration

7-12SUPERSERVER 5038D-i User's ManualThis item allows the generation confi guration of PEG0 on the PCI-E slot. The options are Auto, Gen1, Gen2 a

Strany 103 - 7-5 Boot Settings

Chapter 7: BIOS7-13• CAS Latency (tCL)• Minimum Delay Time• CAS to RAS (tRCDmin)• Row Precharge (tRPmin)• Active to Precharege (tRASmin)Memory Frequen

Strany 104

Chapter 1 Introduction1-1 OverviewThe SuperServer 5038D-i is a high-end server comprised of two main subsystems: the SC731i-300B server chassis and th

Strany 105 - 7-6 Security Settings

7-14SUPERSERVER 5038D-i User's ManualEHCI2Select Enabled to enable EHCI (Enhanced Host Controller Interface) Controller 2 for USB 2.0 support. On

Strany 106 - 7-7 Save & Exit

Chapter 7: BIOS7-15SATA Confi gurationof the SATA Devices and displays the following items:SATA ControllersThis item Enables or Disables the built-in

Strany 107

7-16SUPERSERVER 5038D-i User's ManualSerial ATA Port 0~ Port 5This item displays the information detected on the installed SATA drives on the par

Strany 108

Chapter 7: BIOS7-17VGA Palette SnoopSelect Enabled to support VGA palette register snooping which will allow the PCI cards that do not contain their o

Strany 109 - BIOS Error Beep Codes

7-18SUPERSERVER 5038D-i User's Manualment) to boot the computer using a PXE device installed in a LAN port specifi ed. Select Disabled to prevent

Strany 110

Chapter 7: BIOS7-19• SPS Version• ME FW (Firmware) Status Value• ME FW State• ME FW Operation State• ME FW Error Code• ME NM FW Status Value• BIOS Boo

Strany 111 - System Specifi cations

7-20SUPERSERVER 5038D-i User's ManualSOL Change SettingsThis feature specifi es the base I/O port address and the Interrupt Request ad-dress of SO

Strany 112

Chapter 7: BIOS7-21Stop BitsA stop bit indicates the end of a serial data packet. Select 1 Stop Bit for standard serial data communication. Select 2 S

Strany 113 - Regulatory Compliance

7-22SUPERSERVER 5038D-i User's ManualConsole Redirection (for EMS)Select Enabled to use a COM Port selected by the user for Console Redirection.

Strany 114

Chapter 7: BIOS7-237-4 Event LogsChange SMBIOS Event Log SettingsEnabling/Disabling OptionsSMBIOS Event LogChange this item to enable or disable all

Komentáře k této Příručce

Žádné komentáře