SUPERUSER’S MANUALRevision 1.0a®SUPERSERVER 6015C-M3SUPERSERVER 6015C-MT
SUPERSERVER 6015C-M3/6015C-MT User's Manualx
B-6SUPERSERVER 6015C-M3/6015C-MT User's ManualNotes
Appendix C: Intel HostRAID Setup GuidelinesC-1Appendix C Intel HostRAID Setup GuidelinesAfter all the hardware has been installed, you must fi rst confi
C-2SUPERSERVER 6015C-M3/6015C-MT User's ManualThe Intel HostRAID Confi gurationsThe following types of Intel's HostRAID confi gurations are su
Appendix C: Intel HostRAID Setup GuidelinesC-3Using the Intel ICH9R SATA RAID Utility Program1. Creating, Deleting and Resetting RAID Volumes: a. Afte
C-4SUPERSERVER 6015C-M3/6015C-MT User's Manualb. Specify a name for the RAID 0 set and press the <Tab> key or the <Enter> key to go
Appendix C: Intel HostRAID Setup GuidelinesC-5Creating a RAID 1 Volume:a. Select "Create RAID Volume" from the main menu and press the <E
C-6SUPERSERVER 6015C-M3/6015C-MT User's ManualCreating a RAID 10 (RAID 1+ RAID 0):a. Select "Create RAID Volume" from the main menu and
Appendix C: Intel HostRAID Setup GuidelinesC-7Creating a RAID 5 Set (Parity):a. Select "Create RAID Volume" from the main menu and press the
C-8SUPERSERVER 6015C-M3/6015C-MT User's ManualDeleting RAID Volume: Warning: Be sure to back up your data before deleting a RAID set. You
Appendix C: Intel HostRAID Setup GuidelinesC-9Resetting to Non-RAID and Resetting a RAID HDDWarning: Be cautious when you reset a RAID volume HDD to n
Chapter 1 Introduction1-1 OverviewThe SuperServer 6015C-M3/6015C-MT is a dual processor server comprised of two main subsystems: the SC813MTQ-520C 1U
C-10SUPERSERVER 6015C-M3/6015C-MT User's ManualC-2 Installing Windows XP/2000/2003 OS for RAID FunctionsInstalling a New Windows Operating Syste
Appendix D: Software InstallationD-1Driver/Tool Installation Display ScreenNotesClick the icons showing a hand writing on the paper to view the readme
D-2SUPERSERVER 6015C-M3/6015C-MT User's ManualSupero Doctor III Interface Display Screen-I (Health Information)D-2 Confi guring Supero Doctor IIIT
Appendix D: Software InstallationD-3Supero Doctor III Interface Display Screen-II (Remote Control)Note: SD III Software can be downloaded from our We
D-4SUPERSERVER 6015C-M3/6015C-MT User's ManualNotes
E-1Appendix E: System Specifi cationsAppendix E System Specifi cationsProcessors Dual Intel® Xeon 5400/5300/5200/5100 Series processors in LGA771
E-2SUPERSERVER 6015C-M3/6015C-MT User's ManualServerboard 6015C-M3: X7DCL-3 (ATX Form Factor) 6015C-MT: X7DCL-i (ATX Form Factor)
E-3Appendix E: System Specifi cationsRegulatory Compliance Electromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-3, CISPR
E-4SUPERSERVER 6015C-M3/6015C-MT User's ManualDisclaimer (continued from front)The products sold by Supermicro are not intended for and will not
1-2SUPERSERVER 6015C-M3/6015C-MT User's Manual1-2 Serverboard FeaturesAt the heart of the SuperServer 6015C-M3/6015C-MT lies the X7DCL-3/X7DCL-i,
Chapter 1: Introduction1-3Ethernet PortsThe X7DCL-3/X7DCL-i has two network controllers integrated into the chipset to support two Gigabit LAN ports (
1-4SUPERSERVER 6015C-M3/6015C-MT User's ManualFigure 1-1 . Intel 5100 Chipset: System Block Diagram Note: This is a general block diagram. Plea
Chapter 1: Introduction1-51-3 Server Chassis FeaturesThe following is a general outline of the main features of the SC813MTQ-520C chassis. Details on
1-6SUPERSERVER 6015C-M3/6015C-MT User's Manual1-4 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA
Chapter 2: Server Installation2-1Chapter 2 Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get your SuperServer 6015C-
2-2SUPERSERVER 6015C-M3/6015C-MT User's Manual!!Warnings and Precautions!This product is for installation only in a Restricted Access Location (d
Chapter 2: Server Installation2-3Rack Mounting ConsiderationsAmbient Operating TemperatureIf installed in a closed or multi-unit rack assembly, the am
Manual Revision 1.0a Release Date: October 6, 2008The information in this User’s Manual has been carefully reviewed and is believed to be accura
2-4SUPERSERVER 6015C-M3/6015C-MT User's Manual2-4 Installing the System into a RackThis section provides information on installing the SuperServ
Chapter 2: Server Installation2-5Installing the Rack RailsDetermine where you want to place the SuperServer 6015C-M3/6015C-MT in the rack (see Rack an
2-6SUPERSERVER 6015C-M3/6015C-MT User's ManualFigure 2-2. Installing the Server into a Rack (with optional front bezel shown)Installing the Serv
Chapter 2: Server Installation2-7Figure 2-3. Installing the Server into a Telco Rack (with optional front bezel shown)Installing the Server into a T
2-8SUPERSERVER 6015C-M3/6015C-MT User's Manual2-5 Checking the Serverboard SetupAfter you install the 6015C-M3/6015C-MT in the rack, you will ne
Chapter 2: Server Installation2-9Figure 2-4.Accessing the Inside of the SuperServer 6015C-M3/6015C-MT
2-10SUPERSERVER 6015C-M3/6015C-MT User's Manual2-6 Checking the Chassis SetupNext, you should check to make sure the peripheral drives and the S
Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are several LEDs on the control panel as well as others on the SAS/SATA driv
3-2SUPERSERVER 6015C-M3/6015C-MT User's Manual3-3 Control Panel LEDsThe control panel located on the front of the SC813MTQ-520C chassis has fi ve
Chapter 3: System Interface3-3PowerIndicates power is being supplied to the system's power supply units. This LED should normally be illuminated
PrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the installation an
3-4SUPERSERVER 6015C-M3/6015C-MT User's ManualNotes
Chapter 4: System Safety4-1Chapter 4 System Safety4-1 Electrical Safety Precautions!Basic electrical safety precautions should be followed to protect
SUPERSERVER 6015C-M3/6015C-MT User's Manual4-2Serverboard Battery: • CAUTION - There is a danger of explosion if the onboard battery is installe
Chapter 4: System Safety4-3After accessing the inside of the system, close the system back up and secure • it to the rack unit with the retention scre
SUPERSERVER 6015C-M3/6015C-MT User's Manual4-44-4 Operating PrecautionsCare must be taken to assure that the chassis cover is in place when the 6
Chapter 5: Advanced Serverboard Setup5-1Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to install the X7DCL-3/X7DCL-i serv
5-2SUPERSERVER 6015C-M3/6015C-MT User's ManualUnpackingThe serverboard is shipped in antistatic packaging to avoid electrical static dis-charge.
Chapter 5: Advanced Serverboard Setup5-35-3 Connecting CablesNow that the serverboard is installed, the next step is to connect the cables to the boar
5-4SUPERSERVER 6015C-M3/6015C-MT User's Manual5-4 I/O PortsThe I/O ports are color coded in conformance with the PC 99 specifi cation. See Figure
Chapter 5: Advanced Serverboard Setup5-55-5 Processor and Heatsink InstallationIMPORTANT! Always connect the power cord last and remove it fi rst befo
SUPERSERVER 6015C-M3/6015C-MT User's ManualivChapter 4: System SafetyYou should thoroughly familiarize yourself with this chapter for a general
5-6SUPERSERVER 6015C-M3/6015C-MT User's ManualSocket keyCPU installed in socketPnP cap released from load plate3. Use your thumb and your index fi
Chapter 5: Advanced Serverboard Setup5-7Warning! We do not recommend that the CPU or the heatsink be removed. However, if you do need to uninstall the
5-8SUPERSERVER 6015C-M3/6015C-MT User's Manual5-6 Installing MemoryMemory SupportThe X7DCL-3/X7DCL-i supports up to 48 GB of Registered ECC DDR2-
Chapter 5: Advanced Serverboard Setup5-95-7 Adding PCI CardsThe 6015C-M3/6015C-MT includes a preinstalled riser card (p/n CSE-RR1U-E8) designed speci
5-10SUPERSERVER 6015C-M3/6015C-MT User's ManualFigure 5-4. X7DCL-3/X7DCL-i LayoutSAS components are included on the X7DCL-3 only.Jumpers not indi
Chapter 5: Advanced Serverboard Setup5-11X7DCL-3/X7DCL-i Quick ReferenceJumper Description Default SettingJBT1 CMOS Clear See Section 5-9JI2C1/JI2C2 I
5-12SUPERSERVER 6015C-M3/6015C-MT User's ManualReset ConnectorThe reset connector is located on pins 3 and 4 of JF1 and attaches to the reset swi
Chapter 5: Advanced Serverboard Setup5-13Overheat LED (OH)Connect an LED to the OH connection on pins 7 and 8 of JF1 to provide ad-vanced warning of c
5-14SUPERSERVER 6015C-M3/6015C-MT User's ManualChassis IntrusionThe Chassis Intrusion header is des-ignated JL1. See the board layout for the loc
Chapter 5: Advanced Serverboard Setup5-15Wake-On-LANThe Wake-On-LAN header is des-ignated JWOL on the serverboard. See the table on the right for pin
vPrefaceNotes
5-16SUPERSERVER 6015C-M3/6015C-MT User's ManualAlarm ResetIf redundant power supplies are installed and the Power Supply Fail Detect jumper (JPWF
Chapter 5: Advanced Serverboard Setup5-17Serial PortsTwo serial ports are included on the serverboard: COM1 is a port located beside the USB ports and
5-18SUPERSERVER 6015C-M3/6015C-MT User's Manual5-10 Jumper SettingsExplanation of JumpersTo modify the operation of the serverboard, jumpers can
Chapter 5: Advanced Serverboard Setup5-19Watch DogJWD enables the Watch Dog function, a system monitor that takes action when a software application f
5-20SUPERSERVER 6015C-M3/6015C-MT User's Manual5-11 Onboard IndicatorsLAN1/LAN2 LEDsThe Ethernet ports (located beside the VGA port) have two LED
Chapter 5: Advanced Serverboard Setup5-21CPU_VRM Overheat LED Indicators (LED5/LED6)The two CPU_VRM Overheat LEDs designated LE5/LE6 provide indicatio
5-22SUPERSERVER 6015C-M3/6015C-MT User's ManualIDE ConnectorThere are no jumpers to confi gure the onboard IDE interface "IDE". See the
Chapter 5: Advanced Serverboard Setup5-23SAS PortsThere are eight SAS ports included on the serverboard. See the table on the right for pin defi nition
5-24SUPERSERVER 6015C-M3/6015C-MT User's ManualNotes
Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform main-tena
viSUPERSERVER 6015C-M3/6015C-MT User's ManualTable of ContentsChapter 1 Introduction1-1 Overview ...
6-2SUPERSERVER 6015C-M3/6015C-MT User's ManualFigure 6-2. Chassis Rear View6-2 Control PanelThe control panel (located on the front of the chass
Chapter 6: Advanced Chassis Setup6-36-3 System FansFour 4-cm high-performance 12500 rpm fans provide the cooling for the SuperServer 6015C-M3/6015C-MT
6-4SUPERSERVER 6015C-M3/6015C-MT User's ManualUse caution when working around the SAS/SATA backplane. Do not touch the backplane with any metal
Chapter 6: Advanced Chassis Setup6-5Figure 6-4. Mounting a Drive in a CarrierFigure 6-5. Removing a SAS/SATA Drive from the Server
6-6SUPERSERVER 6015C-M3/6015C-MT User's ManualDVD-ROM Drive InstallationThe top cover of the chassis must be opened to gain full access to the DV
Chapter 6: Advanced Chassis Setup6-76-5 Power SupplyThe SuperServer 6015C-M3/6015C-MT has a single 520 watt power supply. This power supply has the ca
6-8SUPERSERVER 6015C-M3/6015C-MT User's ManualReconnect the power cord.4. Replace the chassis top cover and push the module back into the rack.5.
Chapter 7: BIOS7-1Chapter 7 BIOS7-1 IntroductionThis chapter describes the Phoenix BIOS™ Setup utility for the X7DCL-3/X7DCL-i. The Phoenix ROM BIOS i
7-2SUPERSERVER 6015C-M3/6015C-MT User's Manual7-2 Running SetupDefault settings are in bold text unless otherwise noted.The BIOS setup options de
Chapter 7: BIOS7-3Main BIOS Setup MenuMain Setup FeaturesSystem TimeTo set the system date and time, key in the correct information in the appropriate
viiTable of ContentsInstalling the Server into a Telco Rack ... 2-72-5 Checking the Serverboa
7-4SUPERSERVER 6015C-M3/6015C-MT User's ManualXIDE Primary Master/Slave, SATA Port1, SATA Port2, SATA Port3 and SATA Port4These settings allow th
Chapter 7: BIOS7-5CHS FormatThe following items will be displayed by the BIOS:TYPE: This item displays the type of IDE or SATA Device.Cylinders: This
7-6SUPERSERVER 6015C-M3/6015C-MT User's ManualSerial ATAThis setting allows the user to enable or disable the function of the Serial ATA. The op
Chapter 7: BIOS7-77-4 Advanced Setup Choose Advanced from the Phoenix BIOS Setup Utility main menu with the arrow keys. You should see the followin
7-8SUPERSERVER 6015C-M3/6015C-MT User's ManualPower Button BehaviorIf set to Instant-Off, the system will power off immediately as soon as the us
Chapter 7: BIOS7-9Cache Base 0-512KIf enabled, this feature will allow the data stored in the base memory area: block 0-512K to be cached (written) in
7-10SUPERSERVER 6015C-M3/6015C-MT User's ManualXPCI Confi gurationAccess the submenu to make changes to the following settings for PCI devices.Onb
Chapter 7: BIOS7-11XAdvanced Chipset ControlAccess the submenu to make changes to the following settings.Warning: Take Caution when changing the Advan
7-12SUPERSERVER 6015C-M3/6015C-MT User's ManualXAdvanced Processor OptionsAccess the submenu to make changes to the following settings. CPU Speed
Chapter 7: BIOS7-13and restart the system for the change to take effect. Please refer to Intel’s web site for detailed information.Intel EIST Support
viiiSUPERSERVER 6015C-M3/6015C-MT User's ManualATX Power Connector ...
7-14SUPERSERVER 6015C-M3/6015C-MT User's ManualFloppy Disk ControllerThis setting allows you to assign control of the fl oppy disk controller. Th
Chapter 7: BIOS7-15XConsole RedirectionAccess the submenu to make changes to the following settings. COM Port AddressThis item allows you to specify w
7-16SUPERSERVER 6015C-M3/6015C-MT User's ManualXHardware Monitor LogicCPU Temperature ThresholdThis option allows the user to set a CPU temperatu
Chapter 7: BIOS7-17XIPMI (Available only when an IPMI card is installed.)0IP0M0000I Specification Version: This item displays the current IPMI Version
7-18SUPERSERVER 6015C-M3/6015C-MT User's ManualOS Boot Watch DogSet to Enabled to enable OS Boot Watch Dog. The options are Enabled and Disabled.
Chapter 7: BIOS7-19XRealtime Sensor DataThis feature display information from motherboard sensors, such as temperatures, fan speeds and voltages of va
7-20SUPERSERVER 6015C-M3/6015C-MT User's Manual7-5 SecurityChoose Security from the Phoenix BIOS Setup Utility main menu with the arrow keys. Yo
Chapter 7: BIOS7-21Password on BootThis setting allows you to determine if a password is required for a user to enter the system at bootup. The opti
7-22SUPERSERVER 6015C-M3/6015C-MT User's Manual7-7 ExitChoose Exit from the Phoenix BIOS Setup Utility main menu with the arrow keys. You should
A-1Appendix A: BIOS POST MessagesAppendix A BIOS POST MessagesDuring the Power-On Self-Test (POST), the BIOS will check for problems. If a problem is
ix5-12 Floppy and IDE Drive Connections... 5-21Floppy Connector ...
A-2SUPERSERVER 6015C-M3/6015C-MT User's ManualSystem CMOS checksum bad - Default confi guration usedSystem CMOS has been corrupted or modifi ed inc
A-3Appendix A: BIOS POST MessagesEISA CMOS not writeableServerBIOS2 test error: Cannot write to EISA CMOS.DMA Test FailedServerBIOS2 test error: Canno
A-4SUPERSERVER 6015C-M3/6015C-MT User's Manualnnnn kB Extended RAM PassedWhere nnnn is the amount of RAM in kilobytes successfully tested.nnnn Ca
A-5Appendix A: BIOS POST MessagesPS/2 Mouse:PS/2 mouse identifi ed.Run the I2O Confi guration UtilityOne or more unclaimed block storage devices have th
A-6SUPERSERVER 6015C-M3/6015C-MT User's ManualNotes
Appendix B: BIOS POST CodesB-1This section lists the POST (Power On Self Test) codes for the Phoenix BIOS. POST codes are divided into two categories
B-2SUPERSERVER 6015C-M3/6015C-MT User's ManualPOST Code Description18h 8254 timer initialization1Ah 8237 DMA controller initialization1
Appendix B: BIOS POST CodesB-3POST Code Description5Ch Test RAM between 512 and 640 kB60h Test extended memory62h Test extended memory a
B-4SUPERSERVER 6015C-M3/6015C-MT User's ManualPOST Code Description99h Check for SMART Drive (optional)9Ch Set up Power Management9Dh
Appendix B: BIOS POST CodesB-5The following are for boot block in Flash ROMPOST Code DescriptionE0h Initialize the chipsetE1h Initialize the
Komentáře k této Příručce