Supermicro SYS-6015C-MTB Datový list

Procházejte online nebo si stáhněte Datový list pro Barebone serveru Supermicro SYS-6015C-MTB. Supermicro 6015C-MTB Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 118
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků

Shrnutí obsahu

Strany 1 - SUPER

SUPERUSER’S MANUALRevision 1.0a®SUPERSERVER 6015C-M3SUPERSERVER 6015C-MT

Strany 2 - Release Date: October 6, 2008

SUPERSERVER 6015C-M3/6015C-MT User's Manualx

Strany 3 - Manual Organization

B-6SUPERSERVER 6015C-M3/6015C-MT User's ManualNotes

Strany 4

Appendix C: Intel HostRAID Setup GuidelinesC-1Appendix C Intel HostRAID Setup GuidelinesAfter all the hardware has been installed, you must fi rst confi

Strany 5

C-2SUPERSERVER 6015C-M3/6015C-MT User's ManualThe Intel HostRAID Confi gurationsThe following types of Intel's HostRAID confi gurations are su

Strany 6 - Table of Contents

Appendix C: Intel HostRAID Setup GuidelinesC-3Using the Intel ICH9R SATA RAID Utility Program1. Creating, Deleting and Resetting RAID Volumes: a. Afte

Strany 7 - Chapter 4 System Safety

C-4SUPERSERVER 6015C-M3/6015C-MT User's Manualb. Specify a name for the RAID 0 set and press the <Tab> key or the <Enter> key to go

Strany 8

Appendix C: Intel HostRAID Setup GuidelinesC-5Creating a RAID 1 Volume:a. Select "Create RAID Volume" from the main menu and press the <E

Strany 9

C-6SUPERSERVER 6015C-M3/6015C-MT User's ManualCreating a RAID 10 (RAID 1+ RAID 0):a. Select "Create RAID Volume" from the main menu and

Strany 10

Appendix C: Intel HostRAID Setup GuidelinesC-7Creating a RAID 5 Set (Parity):a. Select "Create RAID Volume" from the main menu and press the

Strany 11 - Introduction

C-8SUPERSERVER 6015C-M3/6015C-MT User's ManualDeleting RAID Volume: Warning: Be sure to back up your data before deleting a RAID set. You

Strany 12 - 1-2 Serverboard Features

Appendix C: Intel HostRAID Setup GuidelinesC-9Resetting to Non-RAID and Resetting a RAID HDDWarning: Be cautious when you reset a RAID volume HDD to n

Strany 13 - Ethernet Ports

Chapter 1 Introduction1-1 OverviewThe SuperServer 6015C-M3/6015C-MT is a dual processor server comprised of two main subsystems: the SC813MTQ-520C 1U

Strany 14 - System Block Diagram

C-10SUPERSERVER 6015C-M3/6015C-MT User's ManualC-2 Installing Windows XP/2000/2003 OS for RAID FunctionsInstalling a New Windows Operating Syste

Strany 15 - 1-3 Server Chassis Features

Appendix D: Software InstallationD-1Driver/Tool Installation Display ScreenNotesClick the icons showing a hand writing on the paper to view the readme

Strany 16 - 1-4 Contacting Supermicro

D-2SUPERSERVER 6015C-M3/6015C-MT User's ManualSupero Doctor III Interface Display Screen-I (Health Information)D-2 Confi guring Supero Doctor IIIT

Strany 17 - Server Installation

Appendix D: Software InstallationD-3Supero Doctor III Interface Display Screen-II (Remote Control)Note: SD III Software can be downloaded from our We

Strany 18 - Warnings and Precautions!

D-4SUPERSERVER 6015C-M3/6015C-MT User's ManualNotes

Strany 19 - Rack Mounting Considerations

E-1Appendix E: System Specifi cationsAppendix E System Specifi cationsProcessors Dual Intel® Xeon 5400/5300/5200/5100 Series processors in LGA771

Strany 20

E-2SUPERSERVER 6015C-M3/6015C-MT User's ManualServerboard 6015C-M3: X7DCL-3 (ATX Form Factor) 6015C-MT: X7DCL-i (ATX Form Factor)

Strany 21 - Installing the Rack Rails

E-3Appendix E: System Specifi cationsRegulatory Compliance Electromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-3, CISPR

Strany 22

E-4SUPERSERVER 6015C-M3/6015C-MT User's ManualDisclaimer (continued from front)The products sold by Supermicro are not intended for and will not

Strany 23

1-2SUPERSERVER 6015C-M3/6015C-MT User's Manual1-2 Serverboard FeaturesAt the heart of the SuperServer 6015C-M3/6015C-MT lies the X7DCL-3/X7DCL-i,

Strany 24

Chapter 1: Introduction1-3Ethernet PortsThe X7DCL-3/X7DCL-i has two network controllers integrated into the chipset to support two Gigabit LAN ports (

Strany 25 - Figure 2-4

1-4SUPERSERVER 6015C-M3/6015C-MT User's ManualFigure 1-1 . Intel 5100 Chipset: System Block Diagram Note: This is a general block diagram. Plea

Strany 26

Chapter 1: Introduction1-51-3 Server Chassis FeaturesThe following is a general outline of the main features of the SC813MTQ-520C chassis. Details on

Strany 27 - System Interface

1-6SUPERSERVER 6015C-M3/6015C-MT User's Manual1-4 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA

Strany 28 - 3-3 Control Panel LEDs

Chapter 2: Server Installation2-1Chapter 2 Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get your SuperServer 6015C-

Strany 29 - 3-4 Drive Carrier LEDs

2-2SUPERSERVER 6015C-M3/6015C-MT User's Manual!!Warnings and Precautions!This product is for installation only in a Restricted Access Location (d

Strany 30

Chapter 2: Server Installation2-3Rack Mounting ConsiderationsAmbient Operating TemperatureIf installed in a closed or multi-unit rack assembly, the am

Strany 31 - System Safety

Manual Revision 1.0a Release Date: October 6, 2008The information in this User’s Manual has been carefully reviewed and is believed to be accura

Strany 32

2-4SUPERSERVER 6015C-M3/6015C-MT User's Manual2-4 Installing the System into a RackThis section provides information on installing the SuperServ

Strany 33 - 4-3 ESD Precautions

Chapter 2: Server Installation2-5Installing the Rack RailsDetermine where you want to place the SuperServer 6015C-M3/6015C-MT in the rack (see Rack an

Strany 34 - BATTERY HOLDER BATTERY HOLDER

2-6SUPERSERVER 6015C-M3/6015C-MT User's ManualFigure 2-2. Installing the Server into a Rack (with optional front bezel shown)Installing the Serv

Strany 35 - Advanced Serverboard Setup

Chapter 2: Server Installation2-7Figure 2-3. Installing the Server into a Telco Rack (with optional front bezel shown)Installing the Server into a T

Strany 36 - 5-2 Serverboard Installation

2-8SUPERSERVER 6015C-M3/6015C-MT User's Manual2-5 Checking the Serverboard SetupAfter you install the 6015C-M3/6015C-MT in the rack, you will ne

Strany 37 - 5-3 Connecting Cables

Chapter 2: Server Installation2-9Figure 2-4.Accessing the Inside of the SuperServer 6015C-M3/6015C-MT

Strany 38 - 5-4 I/O Ports

2-10SUPERSERVER 6015C-M3/6015C-MT User's Manual2-6 Checking the Chassis SetupNext, you should check to make sure the peripheral drives and the S

Strany 39 - Load plate released

Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are several LEDs on the control panel as well as others on the SAS/SATA driv

Strany 40

3-2SUPERSERVER 6015C-M3/6015C-MT User's Manual3-3 Control Panel LEDsThe control panel located on the front of the SC813MTQ-520C chassis has fi ve

Strany 41

Chapter 3: System Interface3-3PowerIndicates power is being supplied to the system's power supply units. This LED should normally be illuminated

Strany 42 - 5-6 Installing Memory

PrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the installation an

Strany 43 - 5-7 Adding PCI Cards

3-4SUPERSERVER 6015C-M3/6015C-MT User's ManualNotes

Strany 44 - 5-8 Serverboard Details

Chapter 4: System Safety4-1Chapter 4 System Safety4-1 Electrical Safety Precautions!Basic electrical safety precautions should be followed to protect

Strany 45 - Connector Description

SUPERSERVER 6015C-M3/6015C-MT User's Manual4-2Serverboard Battery: • CAUTION - There is a danger of explosion if the onboard battery is installe

Strany 46 - 5-9 Connector Defi nitions

Chapter 4: System Safety4-3After accessing the inside of the system, close the system back up and secure • it to the rack unit with the retention scre

Strany 47

SUPERSERVER 6015C-M3/6015C-MT User's Manual4-44-4 Operating PrecautionsCare must be taken to assure that the chassis cover is in place when the 6

Strany 48

Chapter 5: Advanced Serverboard Setup5-1Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to install the X7DCL-3/X7DCL-i serv

Strany 49

5-2SUPERSERVER 6015C-M3/6015C-MT User's ManualUnpackingThe serverboard is shipped in antistatic packaging to avoid electrical static dis-charge.

Strany 50

Chapter 5: Advanced Serverboard Setup5-35-3 Connecting CablesNow that the serverboard is installed, the next step is to connect the cables to the boar

Strany 51

5-4SUPERSERVER 6015C-M3/6015C-MT User's Manual5-4 I/O PortsThe I/O ports are color coded in conformance with the PC 99 specifi cation. See Figure

Strany 52 - 5-10 Jumper Settings

Chapter 5: Advanced Serverboard Setup5-55-5 Processor and Heatsink InstallationIMPORTANT! Always connect the power cord last and remove it fi rst befo

Strany 53

SUPERSERVER 6015C-M3/6015C-MT User's ManualivChapter 4: System SafetyYou should thoroughly familiarize yourself with this chapter for a general

Strany 54 - 5-11 Onboard Indicators

5-6SUPERSERVER 6015C-M3/6015C-MT User's ManualSocket keyCPU installed in socketPnP cap released from load plate3. Use your thumb and your index fi

Strany 55 - LED6: On CPU2_VRM Overheat

Chapter 5: Advanced Serverboard Setup5-7Warning! We do not recommend that the CPU or the heatsink be removed. However, if you do need to uninstall the

Strany 56

5-8SUPERSERVER 6015C-M3/6015C-MT User's Manual5-6 Installing MemoryMemory SupportThe X7DCL-3/X7DCL-i supports up to 48 GB of Registered ECC DDR2-

Strany 57

Chapter 5: Advanced Serverboard Setup5-95-7 Adding PCI CardsThe 6015C-M3/6015C-MT includes a preinstalled riser card (p/n CSE-RR1U-E8) designed speci

Strany 58

5-10SUPERSERVER 6015C-M3/6015C-MT User's ManualFigure 5-4. X7DCL-3/X7DCL-i LayoutSAS components are included on the X7DCL-3 only.Jumpers not indi

Strany 59 - Advanced Chassis Setup

Chapter 5: Advanced Serverboard Setup5-11X7DCL-3/X7DCL-i Quick ReferenceJumper Description Default SettingJBT1 CMOS Clear See Section 5-9JI2C1/JI2C2 I

Strany 60 - 6-2 Control Panel

5-12SUPERSERVER 6015C-M3/6015C-MT User's ManualReset ConnectorThe reset connector is located on pins 3 and 4 of JF1 and attaches to the reset swi

Strany 61 - 6-3 System Fans

Chapter 5: Advanced Serverboard Setup5-13Overheat LED (OH)Connect an LED to the OH connection on pins 7 and 8 of JF1 to provide ad-vanced warning of c

Strany 62 - SAS/SATA Drive Installation

5-14SUPERSERVER 6015C-M3/6015C-MT User's ManualChassis IntrusionThe Chassis Intrusion header is des-ignated JL1. See the board layout for the loc

Strany 63

Chapter 5: Advanced Serverboard Setup5-15Wake-On-LANThe Wake-On-LAN header is des-ignated JWOL on the serverboard. See the table on the right for pin

Strany 65 - 6-5 Power Supply

5-16SUPERSERVER 6015C-M3/6015C-MT User's ManualAlarm ResetIf redundant power supplies are installed and the Power Supply Fail Detect jumper (JPWF

Strany 66 - Reconnect the power cord.4

Chapter 5: Advanced Serverboard Setup5-17Serial PortsTwo serial ports are included on the serverboard: COM1 is a port located beside the USB ports and

Strany 67 - Chapter 7

5-18SUPERSERVER 6015C-M3/6015C-MT User's Manual5-10 Jumper SettingsExplanation of JumpersTo modify the operation of the serverboard, jumpers can

Strany 68 - 7-3 Main BIOS Setup

Chapter 5: Advanced Serverboard Setup5-19Watch DogJWD enables the Watch Dog function, a system monitor that takes action when a software application f

Strany 69 - Main BIOS Setup Menu

5-20SUPERSERVER 6015C-M3/6015C-MT User's Manual5-11 Onboard IndicatorsLAN1/LAN2 LEDsThe Ethernet ports (located beside the VGA port) have two LED

Strany 70

Chapter 5: Advanced Serverboard Setup5-21CPU_VRM Overheat LED Indicators (LED5/LED6)The two CPU_VRM Overheat LEDs designated LE5/LE6 provide indicatio

Strany 71

5-22SUPERSERVER 6015C-M3/6015C-MT User's ManualIDE ConnectorThere are no jumpers to confi gure the onboard IDE interface "IDE". See the

Strany 72

Chapter 5: Advanced Serverboard Setup5-23SAS PortsThere are eight SAS ports included on the serverboard. See the table on the right for pin defi nition

Strany 73 - 7-4 Advanced Setup

5-24SUPERSERVER 6015C-M3/6015C-MT User's ManualNotes

Strany 74

Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform main-tena

Strany 75 - Discrete MTRR Allocation

viSUPERSERVER 6015C-M3/6015C-MT User's ManualTable of ContentsChapter 1 Introduction1-1 Overview ...

Strany 76

6-2SUPERSERVER 6015C-M3/6015C-MT User's ManualFigure 6-2. Chassis Rear View6-2 Control PanelThe control panel (located on the front of the chass

Strany 77

Chapter 6: Advanced Chassis Setup6-36-3 System FansFour 4-cm high-performance 12500 rpm fans provide the cooling for the SuperServer 6015C-M3/6015C-MT

Strany 78

6-4SUPERSERVER 6015C-M3/6015C-MT User's ManualUse caution when working around the SAS/SATA backplane. Do not touch the backplane with any metal

Strany 79

Chapter 6: Advanced Chassis Setup6-5Figure 6-4. Mounting a Drive in a CarrierFigure 6-5. Removing a SAS/SATA Drive from the Server

Strany 80

6-6SUPERSERVER 6015C-M3/6015C-MT User's ManualDVD-ROM Drive InstallationThe top cover of the chassis must be opened to gain full access to the DV

Strany 81

Chapter 6: Advanced Chassis Setup6-76-5 Power SupplyThe SuperServer 6015C-M3/6015C-MT has a single 520 watt power supply. This power supply has the ca

Strany 82 - XHardware Monitor Logic

6-8SUPERSERVER 6015C-M3/6015C-MT User's ManualReconnect the power cord.4. Replace the chassis top cover and push the module back into the rack.5.

Strany 83

Chapter 7: BIOS7-1Chapter 7 BIOS7-1 IntroductionThis chapter describes the Phoenix BIOS™ Setup utility for the X7DCL-3/X7DCL-i. The Phoenix ROM BIOS i

Strany 84

7-2SUPERSERVER 6015C-M3/6015C-MT User's Manual7-2 Running SetupDefault settings are in bold text unless otherwise noted.The BIOS setup options de

Strany 85 - XRealtime Sensor Data

Chapter 7: BIOS7-3Main BIOS Setup MenuMain Setup FeaturesSystem TimeTo set the system date and time, key in the correct information in the appropriate

Strany 86 - 7-5 Security

viiTable of ContentsInstalling the Server into a Telco Rack ... 2-72-5 Checking the Serverboa

Strany 87 - 7-6 Boot

7-4SUPERSERVER 6015C-M3/6015C-MT User's ManualXIDE Primary Master/Slave, SATA Port1, SATA Port2, SATA Port3 and SATA Port4These settings allow th

Strany 88 - 7-7 Exit

Chapter 7: BIOS7-5CHS FormatThe following items will be displayed by the BIOS:TYPE: This item displays the type of IDE or SATA Device.Cylinders: This

Strany 89 - BIOS POST Messages

7-6SUPERSERVER 6015C-M3/6015C-MT User's ManualSerial ATAThis setting allows the user to enable or disable the function of the Serial ATA. The op

Strany 90

Chapter 7: BIOS7-77-4 Advanced Setup Choose Advanced from the Phoenix BIOS Setup Utility main menu with the arrow keys. You should see the followin

Strany 91

7-8SUPERSERVER 6015C-M3/6015C-MT User's ManualPower Button BehaviorIf set to Instant-Off, the system will power off immediately as soon as the us

Strany 92

Chapter 7: BIOS7-9Cache Base 0-512KIf enabled, this feature will allow the data stored in the base memory area: block 0-512K to be cached (written) in

Strany 93

7-10SUPERSERVER 6015C-M3/6015C-MT User's ManualXPCI Confi gurationAccess the submenu to make changes to the following settings for PCI devices.Onb

Strany 94

Chapter 7: BIOS7-11XAdvanced Chipset ControlAccess the submenu to make changes to the following settings.Warning: Take Caution when changing the Advan

Strany 95 - BIOS POST Codes

7-12SUPERSERVER 6015C-M3/6015C-MT User's ManualXAdvanced Processor OptionsAccess the submenu to make changes to the following settings. CPU Speed

Strany 96 - POST Code Description

Chapter 7: BIOS7-13and restart the system for the change to take effect. Please refer to Intel’s web site for detailed information.Intel EIST Support

Strany 97

viiiSUPERSERVER 6015C-M3/6015C-MT User's ManualATX Power Connector ...

Strany 98

7-14SUPERSERVER 6015C-M3/6015C-MT User's ManualFloppy Disk ControllerThis setting allows you to assign control of the fl oppy disk controller. Th

Strany 99

Chapter 7: BIOS7-15XConsole RedirectionAccess the submenu to make changes to the following settings. COM Port AddressThis item allows you to specify w

Strany 100

7-16SUPERSERVER 6015C-M3/6015C-MT User's ManualXHardware Monitor LogicCPU Temperature ThresholdThis option allows the user to set a CPU temperatu

Strany 101 - Appendix C

Chapter 7: BIOS7-17XIPMI (Available only when an IPMI card is installed.)0IP0M0000I Specification Version: This item displays the current IPMI Version

Strany 102 - The Intel Matrix Storage

7-18SUPERSERVER 6015C-M3/6015C-MT User's ManualOS Boot Watch DogSet to Enabled to enable OS Boot Watch Dog. The options are Enabled and Disabled.

Strany 103

Chapter 7: BIOS7-19XRealtime Sensor DataThis feature display information from motherboard sensors, such as temperatures, fan speeds and voltages of va

Strany 104 - Creating a RAID 0 Volume:

7-20SUPERSERVER 6015C-M3/6015C-MT User's Manual7-5 SecurityChoose Security from the Phoenix BIOS Setup Utility main menu with the arrow keys. Yo

Strany 105 - Creating a RAID 1 Volume:

Chapter 7: BIOS7-21Password on BootThis setting allows you to determine if a password is required for a user to enter the system at bootup. The opti

Strany 106

7-22SUPERSERVER 6015C-M3/6015C-MT User's Manual7-7 ExitChoose Exit from the Phoenix BIOS Setup Utility main menu with the arrow keys. You should

Strany 107

A-1Appendix A: BIOS POST MessagesAppendix A BIOS POST MessagesDuring the Power-On Self-Test (POST), the BIOS will check for problems. If a problem is

Strany 108 - Deleting RAID Volume:

ix5-12 Floppy and IDE Drive Connections... 5-21Floppy Connector ...

Strany 109

A-2SUPERSERVER 6015C-M3/6015C-MT User's ManualSystem CMOS checksum bad - Default confi guration usedSystem CMOS has been corrupted or modifi ed inc

Strany 110 - Functions

A-3Appendix A: BIOS POST MessagesEISA CMOS not writeableServerBIOS2 test error: Cannot write to EISA CMOS.DMA Test FailedServerBIOS2 test error: Canno

Strany 111 - Software Installation

A-4SUPERSERVER 6015C-M3/6015C-MT User's Manualnnnn kB Extended RAM PassedWhere nnnn is the amount of RAM in kilobytes successfully tested.nnnn Ca

Strany 112

A-5Appendix A: BIOS POST MessagesPS/2 Mouse:PS/2 mouse identifi ed.Run the I2O Confi guration UtilityOne or more unclaimed block storage devices have th

Strany 113

A-6SUPERSERVER 6015C-M3/6015C-MT User's ManualNotes

Strany 114

Appendix B: BIOS POST CodesB-1This section lists the POST (Power On Self Test) codes for the Phoenix BIOS. POST codes are divided into two categories

Strany 115 - System Specifi cations

B-2SUPERSERVER 6015C-M3/6015C-MT User's ManualPOST Code Description18h 8254 timer initialization1Ah 8237 DMA controller initialization1

Strany 116 -

Appendix B: BIOS POST CodesB-3POST Code Description5Ch Test RAM between 512 and 640 kB60h Test extended memory62h Test extended memory a

Strany 117 - Regulatory Compliance

B-4SUPERSERVER 6015C-M3/6015C-MT User's ManualPOST Code Description99h Check for SMART Drive (optional)9Ch Set up Power Management9Dh

Strany 118

Appendix B: BIOS POST CodesB-5The following are for boot block in Flash ROMPOST Code DescriptionE0h Initialize the chipsetE1h Initialize the

Komentáře k této Příručce

Žádné komentáře