SUPERSUPERSERVER® 6018R-MT6018R-MTRRevision 1.0®
xSUPERSERVER 6018R-MT/6018R-MTR User's Manual7-5 IPMI ...
7-18SUPERSERVER 6018R-MT/6018R-MTR User's ManualUSB Mass Storage Driver SupportSelect Enabled for USB mass storage device support. The options ar
Chapter 7: BIOS7-19SATA CongurationWhen this submenu is selected, AMI BIOS automatically detects the presence of the SATA devices that are supported
7-20SUPERSERVER 6018R-MT/6018R-MTR User's ManualPort 0 ~ Port 5 SATA Device TypeUse this item to specify if the SATA port specied by t
Chapter 7: BIOS7-21Port 0 ~ Port 5 Hot PlugSelect Enabled to enable hot-plugging support for a port specied by the user, which will allow the user to
7-22SUPERSERVER 6018R-MT/6018R-MTR User's Manual•Software Preserve Support sSATA Port 0~ Port 3Select Enabled to enable an sSATA port specied b
Chapter 7: BIOS7-23sSATA RAID Option ROM/UEFI DriverSelect EFI to load the EFI driver for system boot. Select Legacy to load a legacy driver for syste
7-24SUPERSERVER 6018R-MT/6018R-MTR User's Manual•ME Firmware Status #2•Current State•Error CodePCIe/PCI/PnP CongurationThe following PCI inf
Chapter 7: BIOS7-25Maximum PayloadSelect Auto for the system BIOS to automatically set the maximum payload value for a PCI-E device to enhance system
7-26SUPERSERVER 6018R-MT/6018R-MTR User's ManualVGA PriorityUse this item to select the graphics device to be used as the primary video display f
Chapter 7: BIOS7-27Serial Port Console RedirectionCOM 1COM 1 Console RedirectionSelect Enabled to enable COM Port 1 Console Redirection, which will a
Chapter 1 Introduction1-1 OverviewThe SuperServer 6018R-MT/6018R-MTR is comprised of two main subsystems: the SC813MFTQ-400CB/R400CB 1U chassis and
7-28SUPERSERVER 6018R-MT/6018R-MTR User's ManualStop BitsA stop bit indicates the end of a serial data packet. Select 1 Stop Bit for standard ser
Chapter 7: BIOS7-29SOL/COM2Console RedirectionSelect Enabled to use the SOL port for Console Redirection. The options are Enabled and Disabled. *If th
7-30SUPERSERVER 6018R-MT/6018R-MTR User's ManualFlow ControlUse this feature to set the ow control for Console Redirection to prevent data loss
Chapter 7: BIOS7-31*If the item above set to Enabled, the following items will become available for user's conguration:Out-of-Band Management Po
7-32SUPERSERVER 6018R-MT/6018R-MTR User's ManualTrusted Computing (Available when a TPM device is installed and detected by the BIOS)Congurati
Chapter 7: BIOS7-33ACPI Settings WHEA SupportSelect Enabled to support the Windows Hardware Error Architecture (WHEA) plat-form and provide a common
7-34SUPERSERVER 6018R-MT/6018R-MTR User's Manual7-4 Event LogsUse this feature to congure Event Log settings.Change SMBIOS Event Log Settings
Chapter 7: BIOS7-35Memory Correctable Error ThresholdUse this item to enter the threshold value for correctable memory errors. The default setting is
7-36SUPERSERVER 6018R-MT/6018R-MTR User's Manual7-5 IPMIUse this feature to congure Intelligent Platform Management Interface (IPMI)
Chapter 7: BIOS7-37When SEL is FullThis feature allows the user to determine what the BIOS should do when the sys-tem event log is full. Select Erase
1-2SUPERSERVER 6018R-MT/6018R-MTR User's Manual1-2 Serverboard FeaturesAt the heart of the SuperServer 6018R-MT/6018R-MTR lies the X10DRL-i, a d
7-38SUPERSERVER 6018R-MT/6018R-MTR User's Manual7-6 Security SettingsThis menu allows the user to congure the following security sett
Chapter 7: BIOS7-397-7 Boot SettingsUse this feature to congure Boot Settings:Boot CongurationSetup Prompt TimeoutUse this item to indicate how man
7-40SUPERSERVER 6018R-MT/6018R-MTR User's Manual•Dual Boot Order #7•Dual Boot Order #8•Dual Boot Order #9•Dual Boot Order #10•Dual Boot Orde
Chapter 7: BIOS7-41Network Drive BBS Priorities•Legacy Boot Order #1UEFI Application Boot Priorities•UEFI Boot Order #1
7-42SUPERSERVER 6018R-MT/6018R-MTR User's Manual7-8 Save & ExitSelect the Save & Exit tab from the BIOS setup screen to con
Chapter 7: BIOS7-43Restore DefaultsTo set this feature, select Restore Defaults from the Exit menu and press <Enter>. These are manufacture defa
7-44SUPERSERVER 6018R-MT/6018R-MTR User's ManualNotes
A-1Appendix A: BIOS POST Error CodesAppendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed at each syst
A-2SUPERSERVER 6018R-MT/6018R-MTR User's ManualNotes
B-1Appendix B: System SpecicationsAppendix B System SpecicationsProcessorsTwo Intel® E5-2600 (v3) Series processors in LGA2011 sockets (Socket R)N
1-3Chapter 1: Introduction1-3 Server Chassis FeaturesThe following is a general outline of the main features of the SC813MFTQ-400CB/R400CB chassis.Sy
B-2SUPERSERVER 6018R-MT/6018R-MTR User's ManualChassis6018R-MT: SC813MFTQ-400CB (1U Rackmount)6018R-MTR: SC813MFTQ-R400CB (1U Rackmount)Dimension
B-3Appendix B: System SpecicationsOperating EnvironmentOperating Temperature: 10º to 35º C (50º to 95º F)Non-operating Temperature: -40º to 70º C (-4
B-4SUPERSERVER 6018R-MT/6018R-MTR User's Manual(continued from front)The products sold by Supermicro are not intended for and will not be used in
1-4SUPERSERVER 6018R-MT/6018R-MTR User's ManualFigure 1-1. Intel C612 Chipset: System Block Diagram Note: This is a general block diagram. Pleas
1-5Chapter 1: Introduction1-4 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131 U.S.A.Tel: +1 (408
1-6SUPERSERVER 6018R-MT/6018R-MTR User's ManualNotes
Chapter 2: Server Installation2-1Chapter 2 Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get your SuperServer 6018
2-2SUPERSERVER 6018R-MT/6018R-MTR User's Manualinstallation only in a Restricted Access Location (dedicated equipment rooms, service closets and
Chapter 2: Server Installation2-3Rack Mounting ConsiderationsAmbient Operating TemperatureIf installed in a closed or multi-unit rack assembly, the am
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccur
2-4SUPERSERVER 6018R-MT/6018R-MTR User's Manual2-5 Installing the System into a RackThis section provides information on installing the SuperSer
Chapter 2: Server Installation2-5Installing the Rack RailsDetermine where you want to place the SuperServer 6018R-MT/6018R-MTR in the rack (see Rack a
2-6SUPERSERVER 6018R-MT/6018R-MTR User's ManualFigure 2-2. Installing the Server into a Rack Installing the Server into the RackYou should now h
Chapter 2: Server Installation2-7Figure 2-3. Installing the Server into a Telco Rack Installing the Server into a Telco RackTo install the SuperServe
2-8SUPERSERVER 6018R-MT/6018R-MTR User's ManualNotes
Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are several LEDs on the control panel as well as others on the hard drive
3-2SUPERSERVER 6018R-MT/6018R-MTR User's Manual3-3 Control Panel LEDsThe control panel located on the front of the SC813MFTQ-400CB/R400CB chassi
Chapter 3: System Interface3-3PowerIndicates power is being supplied to the system's power supply units. This LED should normally be illuminated
3-4SUPERSERVER 6018R-MT/6018R-MTR User's ManualNotes
4-1Chapter 4: Warning Statements for AC SystemsChapter 4 Standardized Warning Statements for AC Systems4-1 About Standardized Warning StatementsThe
PrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the installation an
4-2SUPERSERVER 6018R-MT/6018R-MTR User's ManualWarnung WICHTIGE SICHERHEITSHINWEISEDieses Warnsymbol bedeutet Gefahr. Sie benden sich in e
4-3Warning Statements for AC Systems안전을 위한 주의사항경고!이 경고 기호는 위험이 있음을 알려 줍니다. 작업자의 신체에 부상을 야기 할 수 있는 상태에 있게 됩니다. 모든 장비에 대한 작업을 수행하기 전에 전기회로와 관련된 위험요소들을 확
4-4SUPERSERVER 6018R-MT/6018R-MTR User's ManualInstallation Instructions Warning!Read the installation instructions before connecting the system
4-5Chapter 4: Warning Statements for AC SystemsCircuit Breaker Warning!This product relies on the building's installation for short-circuit (over
4-6SUPERSERVER 6018R-MT/6018R-MTR User's ManualPower Disconnection Warning 電源切断の警告システムコンポーネントの取り付けまたは取り外しのために、シャーシー内部にアクセスするには、システムの電源はすべてのソースから切
4-7Chapter 4: Warning Statements for AC Systems¡Advertencia! El sistema debe ser disconnected de todas las fuentes de energía y del cable eléctrico qu
4-8SUPERSERVER 6018R-MT/6018R-MTR User's ManualEquipment Installation機器の設置トレーニングを受け認定された人だけがこの装置の設置、交換、またはサービスを許可されています。 Warning!Only trained and
4-9Chapter 4: Warning Statements for AC Systemsアクセス制限区域このユニットは、アクセス制限区域に設置されることを想定しています。アクセス制限区域は、特別なツール、鍵と錠前、その他のセキュリティの手段を用いてのみ出入りが可能です。 Warning!Thi
4-10SUPERSERVER 6018R-MT/6018R-MTR User's ManualBattery Handling Warning!There is the danger of explosion if the battery is replaced incorrectly.
4-11Chapter 4: Warning Statements for AC SystemsWarnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die Batterie nur
SUPERSERVER 6018R-MT/6018R-MTR User's ManualivChapter 4: Standardized Warning StatementsYou should thoroughly familiarize yourself with this cha
4-12SUPERSERVER 6018R-MT/6018R-MTR User's ManualWarnung Dieses Gerät kann mehr als eine Stromzufuhr haben. Um sicherzustellen, dass der Einheit k
4-13Chapter 4: Warning Statements for AC SystemsBackplane Voltageバックプレーンの電圧システムの稼働中は危険な電圧または電力が、バックプレーン上にかかっています。修理する際には注意ください。警告当系统正在进行时,背板上有很危险的电压或能
4-14SUPERSERVER 6018R-MT/6018R-MTR User's ManualComply with Local and National Electrical Codes Warning!Installation of the equipment must comply
4-15Chapter 4: Warning Statements for AC SystemsProduct Disposal Warning!Ultimate disposal of this product should be handled according to all national
4-16SUPERSERVER 6018R-MT/6018R-MTR User's ManualWaarschuwing De uiteindelijke verwijdering van dit product dient te geschieden in overeenstemming
4-17Chapter 4: Warning Statements for AC SystemsWarnungDie Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halt
4-18SUPERSERVER 6018R-MT/6018R-MTR User's Manual Warning!When installing the product, use the provided or designated connection cables, power cab
4-19Chapter 4: Warning Statements for AC SystemsAttention Lors de l'installation du produit, utilisez les bables de connection fournis ou désigné
4-20SUPERSERVER 6018R-MT/6018R-MTR User's ManualNotes
Chapter 5: Advanced Serverboard Setup5-1Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to install the X10DRL-i serverboa
vPrefaceNotes
5-2SUPERSERVER 6018R-MT/6018R-MTR User's ManualUnpackingThe serverboard is shipped in antistatic packaging to avoid electrical static dis-charge.
Chapter 5: Advanced Serverboard Setup5-35-3 Rear I/O PortsSee Figure 5-2 below for the locations of the various I/O ports located on the back panel o
5-4SUPERSERVER 6018R-MT/6018R-MTR User's Manual1. There are two levers on the LGA2011 socket. First press and release the load lever labeled &ap
Chapter 5: Advanced Serverboard Setup5-5Gently push down to pop the load plate open.3. With the lever labeled 'Close 1st' fully retracted,
5-6SUPERSERVER 6018R-MT/6018R-MTR User's ManualCaution: You can only install the CPU to the socket in one direction. Make sure that the CPU is p
Chapter 5: Advanced Serverboard Setup5-7Installing a Passive CPU Heatsink1. Do not apply any thermal grease to the heatsink or the CPU die -- the re-
5-8SUPERSERVER 6018R-MT/6018R-MTR User's Manual5-5 Installing Memory ModulesNote: Check the Supermicro web site for recommended memory modules.C
Chapter 5: Advanced Serverboard Setup5-9Memory Support for the X10DRL-i ServerboardThe X10DRL-i serverboard supports up to 512 GB of ECC LRDIMM (Load-
5-10SUPERSERVER 6018R-MT/6018R-MTR User's Manual5-6 Adding PCI CardsThe 6018R-MT/6087R-MTR includes an RSC-RR1U-E8 riser card, which ts into a
Chapter 5: Advanced Serverboard Setup5-11Figure 5-5. X10DRL-i LayoutNotes: Jumpers not indicated are for test purposes only. A square contact pad ind
viSUPERSERVER 6018R-MT/6018R-MTR User's ManualTable of ContentsChapter 1 Introduction1-1 Overview ...
5-12SUPERSERVER 6018R-MT/6018R-MTR User's Manual(CPU1) Slot6 PCI-Express 3.0 x8 Slot from CPU1I-SGPIO1/2 Serial Link General Purpose I/O Headers
Chapter 5: Advanced Serverboard Setup5-13Reset ButtonThe reset button connector is located on pins 3 and 4 of JF1 and attaches to the re-set switch on
5-14SUPERSERVER 6018R-MT/6018R-MTR User's ManualNIC2 (LAN2) LEDThe LED connections for LAN2 are on pins 9 and 10 of JF1. Attach LAN LED cables to
Chapter 5: Advanced Serverboard Setup5-15Chassis IntrusionThe Chassis Intrusion header is desig-nated JL1. See the board layout for the location of JL
5-16SUPERSERVER 6018R-MT/6018R-MTR User's ManualUniversal Serial Bus (USB)Two USB 2.0 and two USB 3.0 ports are located on the rear I/O panel. A
Chapter 5: Advanced Serverboard Setup5-17Onboard Speaker (SP1)The onboard speaker provides audible indications for various beep codes. See the table o
5-18SUPERSERVER 6018R-MT/6018R-MTR User's ManualLAN1/2 (Ethernet Ports)Two gigabit Ethernet ports (LAN1 and LAN2) are located on the rear I/O pan
Chapter 5: Advanced Serverboard Setup5-19Standby Power HeaderThe +5V Standby Power header is lo-cated at JSTBY1. See the table on the right for pin
5-20SUPERSERVER 6018R-MT/6018R-MTR User's Manual5-9 Jumper SettingsExplanation of JumpersTo modify the operation of the serverboard, jumpers can
Chapter 5: Advanced Serverboard Setup5-21LAN1/LAN2 Enable/DisableChange the setting of jumper JPL1 and JPL2 to enable or disable the LAN1 and LAN2 por
viiTable of ContentsChapter 3 System Interface3-1 Overview ...
5-22SUPERSERVER 6018R-MT/6018R-MTR User's Manual5-10 Onboard IndicatorsLAN Port LEDsThe LAN1/2 and the dedicated IPMI Eth-ernet ports all have t
Chapter 5: Advanced Serverboard Setup5-23SATA 3.0 PortsTen SATA 3.0 ports are provided on the serverboard. Six (I-SATA 0-5) are supported by the Intel
5-24SUPERSERVER 6018R-MT/6018R-MTR User's Manual5-12 Installing SoftwareThe Supermicro ftp site contains drivers and utilities for your system a
Chapter 5: Advanced Serverboard Setup5-25SuperDoctor® 5The Supermicro SuperDoctor 5 is a program that functions in a command-line or web-based interfa
5-26SUPERSERVER 6018R-MT/6018R-MTR User's Manual5-13 Onboard BatteryPlease handle used batteries carefully. Do not damage the battery in any way
Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform mainte-
6-2SUPERSERVER 6018R-MT/6018R-MTR User's ManualFigure 6-2. Chassis Rear View6-2 Control PanelThe control panel (located on the front of the cha
Chapter 6: Advanced Chassis Setup6-36-3 System FansFour 4-cm high-performance fans provide the cooling for the SuperServer 6018R-MT/6018R-MTR. The ch
6-4SUPERSERVER 6018R-MT/6018R-MTR User's ManualWarning! Use caution when working around the backplane. Do not touch the backplane with any metal
Chapter 6: Advanced Chassis Setup6-5Figure 6-4. Mounting a Drive in a CarrierSATA BackplaneThe SATA drives plug into a backplane that provides power,
viiiSUPERSERVER 6018R-MT/6018R-MTR User's ManualInstalling a Passive CPU Heatsink ...
6-6SUPERSERVER 6018R-MT/6018R-MTR User's ManualDVD-ROM Drive Installation (Optional)The top cover of the chassis must be opened to gain full acce
Chapter 6: Advanced Chassis Setup6-76-5 Power Supply6018R-MTThe SuperServer 6018R-MT has a single 440/480W power supply (PWS-441P-1H). This power sup
6-8SUPERSERVER 6018R-MT/6018R-MTR User's Manual6018R-MTRThe SuperServer 6018R-MTR has a 400 watt redundant power supply consisting of two power m
Chapter 7: BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the AMI BIOS setup utility for the X10DRL-i. The ROM BIOS is stored in a F
7-2SUPERSERVER 6018R-MT/6018R-MTR User's ManualHow to Start the Setup UtilityNormally, the only visible Power-On Self-Test (POST) routine is the
Chapter 7: BIOS7-3The following Main menu items will be displayed:System Date/System Time Use this option to change the system date and time. Highligh
7-4SUPERSERVER 6018R-MT/6018R-MTR User's Manual7-3 Advanced Setup CongurationsUse the arrow keys to select Advanced setup and press <Enter&
Chapter 7: BIOS7-5Wait For 'F1' If ErrorSelect Enabled to force the system to wait until the 'F1' key is pressed if an error occur
7-6SUPERSERVER 6018R-MT/6018R-MTR User's ManualCPU CongurationThis submenu displays the following CPU information as detected by the BIOS. It a
Chapter 7: BIOS7-7codes to overwhelm the processor to damage the system during an attack. This feature is used in conjunction with the items: "Cl
Table of ContentsixVGA Enable/Disable ... 5-21Watch Dog ...
7-8SUPERSERVER 6018R-MT/6018R-MTR User's ManualDCA Prefetch DelayA DCA Prefetcher is used with a TOE (TCP/IP Ofoad Engine) adapter to prefetch d
Chapter 7: BIOS7-9 CPU P State Control (Available when Power Technology is set to Custom)EIST (P-states)EIST (Enhanced Intel SpeedStep Technology) al
7-10SUPERSERVER 6018R-MT/6018R-MTR User's Manual CPU T State Control (Available when Power Technology is set to Custom) ACPI (Advanced Congurat
Chapter 7: BIOS7-11than P0, with its frequency and voltage scaled back a notch. The options are Between P1/P0 and Below P1.Chipset CongurationWarnin
7-12SUPERSERVER 6018R-MT/6018R-MTR User's ManualIOAT (Intel® IO Acceleration) CongurationEnable IOATSelect Enable to enable Intel I/OAT (I/O Ac
Chapter 7: BIOS7-13QPI (Quick Path Interconnect) CongurationQPI StatusThe following information will display:•Number of CPU•Number of IIO•Curren
7-14SUPERSERVER 6018R-MT/6018R-MTR User's ManualIsoc ModeSelect Enabled for Isochronous support to meet QoS (Quality of Service) require-ments. T
Chapter 7: BIOS7-15Memory CongurationEnforce PORSelect Enable to enforce POR restrictions on DDR4 frequency and voltage programming. The options are
7-16SUPERSERVER 6018R-MT/6018R-MTR User's ManualA7 ModeSelect Enabled to support the A7 (Addressing) mode to improve memory per-formance. The opt
Chapter 7: BIOS7-17Patrol Scrub IntervalThis feature allows you to decide how many hours the system should wait before the next complete patrol scrub