SUPERSERVER 7046GT-TRF7046GT-TRF TC47046GT-TRF-FC4057046GT-TRF-FC407 SUPER®USER’S MANUALRevision 1.0d
xSUPERSERVER 7046GT-TRF Series User's ManualNotes
7-14SUPERSERVER 7046GT-TRF Series User's ManualS.M.A.R.T. For Hard disk drivesSelf-Monitoring Analysis and Reporting Technology (SMART) can help
Chapter 7: BIOS7-15Onboard LAN Option ROM 1 SelectThe item selects the type of onboard option ROM to load. The options are PXE and iSCSI. Load Onboard
7-16SUPERSERVER 7046GT-TRF Series User's ManualBase Address, IRQThis item displays the base address and IRQ of the serial port used for Console R
Chapter 7: BIOS7-17Warning! 1. Any temperature that exceeds the CPU threshold temperature pre-defi ned by the CPU manufacturer may result in CPU overhe
7-18SUPERSERVER 7046GT-TRF Series User's ManualLow – This level is considered as the ‘normal’ operating state. The CPU temperature is well below
Chapter 7: BIOS7-19Select "Performance/PF" for better system cooling. The PF setting is recommended for high-power-consuming and high-densit
7-20SUPERSERVER 7046GT-TRF Series User's ManualAPIC ACPI SCI IRQWhen this item is set to Enabled, APIC ACPI SCI IRQ is supported by the system. T
Chapter 7: BIOS7-21If TCG/TPM Support is set to Yes, the TPM Status will display:TPM Enable/Disable StatusTPM Owner StatusIPMI Confi gurationIntellig
7-22SUPERSERVER 7046GT-TRF Series User's ManualClear BMC System Event LogClear BMC System LogSelect OK and press the <Enter> key to clear t
Chapter 7: BIOS7-23Mac Address The BIOS will automatically enter the Mac address of this machine; however it may be over-ridden. Mac addresses are 6 t
Chapter 1 Introduction1-1 OverviewThe SuperServer 7046GT-TRF series is a supercomputing server that is comprised of two main subsystems: the SC747TQ-R
7-24SUPERSERVER 7046GT-TRF Series User's ManualSupervisor Password This item indicates if a Supervisor password has been entered for the system.
Chapter 7: BIOS7-257-5 Boot Confi gurationUse this feature to confi gure boot priority settings. Boot Device PriorityUse this feature to specify the s
7-26SUPERSERVER 7046GT-TRF Series User's ManualRetry Boot DevicesSelect Enabled to enable Retry Boot Devices support to allow the system to attem
Chapter 7: BIOS7-27Load Optimal DefaultsTo set this feature, select Load Optimal Defaults from the Exit menu and press <Enter>. Then, select OK
7-28SUPERSERVER 7046GT-TRF Series User's Manual4.7.1 Boot Sector Recovery from a USB DeviceThis feature allows the user to recover a BIOS image u
Chapter 7: BIOS7-29The "Host system" should also have a serial port and a terminal program that • supports XModem Transfer protocol (Hyper T
7-30SUPERSERVER 7046GT-TRF Series User's Manual6. Once you've completed the instructions given, a screen will display to indicate that remo
Chapter 7: BIOS7-318. Once remote BIOS fl ash is completed, the system will reboot.Note: AMIBIOS Serial Flash will work with any terminal communicatio
7-32SUPERSERVER 7046GT-TRF Series User's ManualNotes
A-1Appendix A: BIOS Error Beep CodesAppendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the
1-2SUPERSERVER 7046GT-TRF Series User's ManualOne (1) Supermicro CD containing drivers and utilities• 1-2 Serverboard FeaturesAt the heart of the
A-2SUPERSERVER 7046GT-TRF Series User's ManualNotes
Appendix B: Installing WindowsB-1Appendix B Installing Windows After all hardware components have been installed, you must fi rst confi gure Intel Sout
B-2SUPERSERVER 7046GT-TRF Series User's ManualB-2 Installing Windows for a Non-RAID SystemInsert Microsoft's Windows XP/Windows 2003 setup
C-1Appendix C: System Specifi cationsAppendix C System Specifi cationsProcessorsTwo Intel 5500/5600 Series processorsNote: Please refer to our web site
C-2SUPERSERVER 7046GT-TRF Series User's ManualExpansion SlotsFour PCI-E Gen. 2.0 x16 slots (Slot 4, Slot 6, Slot 8, Slot 10)• One PCI-E Gen. 1.0
C-3Appendix C: System Specifi cationsRegulatory ComplianceElectromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-3, CISPR 22 Class A
C-4SUPERSERVER 7046GT-TRF Series User's Manual(continued from front)The products sold by Supermicro are not intended for and will not be used in
1-3Chapter 1: IntroductionOnboard Controllers/PortsThe color-coded I/O ports include one COM port (an additional COM header is located on the serverbo
1-4SUPERSERVER 7046GT-TRF Series User's ManualHard Drive/Drive BaysThe SC747 Chassis features eight slots for SAS/SATA drives. These drives are h
1-5Chapter 1: IntroductionFigure 1-1. Intel 5520 Chipset: System Block DiagramNote: This is a general block diagram. Please see Chapter 5 for details.
1-6SUPERSERVER 7046GT-TRF Series User's Manual1-5 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA
Chapter 2: Server Installation2-1Chapter 2 System Setup2-1 OverviewThis chapter provides a quick setup checklist to get your SuperServer 7046GT-TRF se
2-2SUPERSERVER 7046GT-TRF Series User's Manual2-3 Setting Up the SystemYou should fi rst open the left side panel (when facing the front of the c
Chapter 2: Server Installation2-3Check the SATA disk drives: Depending upon your system's confi guration, 2. your system may have up to four SATA
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccu
2-4SUPERSERVER 7046GT-TRF Series User's ManualRack PrecautionsEnsure that the leveling jacks on the bottom of the rack are fully extended to • th
Chapter 2: Server Installation2-5Rack Mounting ConsiderationsAmbient Operating TemperatureIf installed in a closed or multi-unit rack assembly, the am
2-6SUPERSERVER 7046GT-TRF Series User's Manual2-5 Installing the Chassis onto a RackThis section provides information on installing the SC747 ch
Chapter 2: Server Installation2-7Removing the Chassis Top CoverLocate the chassis cover lock (blue lever) at the rear of the chassis cover.1. Slide th
2-8SUPERSERVER 7046GT-TRF Series User's ManualFigure 6-3: Installing the Inner Rack Rails Installing the Chassis Handles and Inner RailsInstallin
Chapter 2: Server Installation2-9Installing the Outer Rails to the RackInstalling the Outer Rails1. Attach the rear bracket to the middle bracket. 2.
2-10SUPERSERVER 7046GT-TRF Series User's ManualFigure 6-5: Installing the Rack RailsInstalling the Chassis into a RackInstalling the Chassis1. Co
Chapter 2: Server Installation2-112-6 Tower Mounting InstructionsThe SC747 chassis is shipped with the chassis cover and feet pre-installed. To use
2-12SUPERSERVER 7046GT-TRF Series User's ManualInstalling Feet on the ChassisInstalling the Chassis FeetPlace the chassis foot in the foot recept
Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are several LEDs on the control panel as well as others on the drive carrier
PrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the installation an
3-2SUPERSERVER 7046GT-TRF Series User's Manual3-2 Control Panel ButtonsThere are two push-buttons located on the front of the chassis. These are
Chapter 3: System Interface3-3NIC2:• Indicates network activity on GLAN2 when fl ashing.Overheat/Fan Fail:• When this LED fl ashes it indicates a fa
3-4SUPERSERVER 7046GT-TRF Series User's Manual3-4 Drive Carrier LEDsYour chassis uses SAS/SATA drives.SAS/SATA DrivesEach SAS/SATA drive carrier
Chapter 4: System Safety4-1Chapter 4 System Safety4-1 Electrical Safety Precautions!Basic electrical safety precautions should be followed to protect
4-2SUPERSERVER 7046GT-TRF Series User's ManualThis product may be connected to an IT power system. In all cases, make sure • that the unit is als
Chapter 4: System Safety4-3Remove any jewelry or metal objects from your body, which are excellent metal • conductors that can create short circuits a
4-4SUPERSERVER 7046GT-TRF Series User's Manual4-4 Operating Precautions!Care must be taken to assure that the chassis cover is in place when the
Chapter 5: Advanced Serverboard Setup5-1Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to install the X8DTG-QF serverboard
5-2SUPERSERVER 7046GT-TRF Series User's Manual!UnpackingThe serverboard is shipped in antistatic packaging to avoid electrical static discharge.
Chapter 5: Advanced Serverboard Setup5-35-3 Connecting CablesNow that the serverboard is installed, the next step is to connect the cables to the boar
SUPERSERVER 7046GT-TRF Series User's ManualivChapter 4: System SafetyYou should thoroughly familiarize yourself with this chapter for a general o
5-4SUPERSERVER 7046GT-TRF Series User's ManualFigure 5-4. Control Panel Header PinsNMIx (key)VccVccVccVccVccVccResetPowerGroundx (key)Power LEDHD
Chapter 5: Advanced Serverboard Setup5-5111715161413121819111112110113114115116117118119Rear I/O Ports1. Keyboard (Purple) 2. PS/2 Mouse (Green)3. COM
5-6SUPERSERVER 7046GT-TRF Series User's Manual5-5 Installing the Processor and Heatsink!Warning: Avoid placing direct pressure to the top of the
Chapter 5: Advanced Serverboard Setup5-7After removing the plastic cap, use 4. your thumb and the index fi nger to hold the CPU at the north and south
5-8SUPERSERVER 7046GT-TRF Series User's ManualInstalling the HeatsinkDo not apply any thermal grease to the 1. heatsink or the CPU die; the requi
Chapter 5: Advanced Serverboard Setup5-9Memory SupportThe X8DTG-QF supports up to 192 GB of registered ECC or up to 48 GB of unbuffered ECC/non-ECC DD
5-10SUPERSERVER 7046GT-TRF Series User's ManualMemory Population for Optimal Performance-For a motherboard with One CPU (CPU1) installedBranch 0
Chapter 5: Advanced Serverboard Setup5-11DIMM Module Population Confi gurationFor memory to work properly, follow the tables below for memory installat
5-12SUPERSERVER 7046GT-TRF Series User's ManualMemory Support for Serverboards with 5600 Processors1.5V DIMMs• 1.5V RDIMM Population for Serverbo
Chapter 5: Advanced Serverboard Setup5-131.5V UDIMM Population for Serverboards with 5600 Processors InstalledDIMM Slots per ChannelDIMMs Populated pe
vPrefaceNotes
5-14SUPERSERVER 7046GT-TRF Series User's ManualPress the Middle of the Release TabLift the Release TabFigure 5-7: Add-on Card/Expansion Card Port
Chapter 5: Advanced Serverboard Setup5-15Figure 5-8: Removing the PCI Card Slot GuardPull the release tab upward.3. Remove the screw holding the brack
5-16SUPERSERVER 7046GT-TRF Series User's ManualInstalling Double-Width Graphics CardsThe SC747 chassis is designed to support up to four double-w
Chapter 5: Advanced Serverboard Setup5-17Figure 5-10: Closing the Graphics Card BracketPlace the tabs of the (part number) graphics card bracket into
5-18SUPERSERVER 7046GT-TRF Series User's ManualFigure 5-11. X8DTG-QF Layout(not drawn to scale)5-7 Serverboard DetailsNotes:Jumpers not indicated
Chapter 5: Advanced Serverboard Setup5-19X8DTG-QF Quick ReferenceJumper Description Default SettingJBT1 CMOS Clear (See Section 2-8)JI2C1/JI2C2 SMB to
5-20SUPERSERVER 7046GT-TRF Series User's Manual5-8 Connector Defi nitions Power ConnectionsA 24-pin main power supply connector(JPW1) and two 8-pi
Chapter 5: Advanced Serverboard Setup5-21Power Button ConnectorThe PW_ON connector is on pins 1 and 2 of JF1. Momentarily contacting both pins will po
5-22SUPERSERVER 7046GT-TRF Series User's ManualNIC2 LEDPin Defi nitions (JF1)Pin# Defi nition 9 Vcc10 GroundNIC2 (JLAN2) LEDThe LED connectio
Chapter 5: Advanced Serverboard Setup5-23Fan HeadersThe X8DTG-QF has ten chassis/system fan headers (Fan1 to Fan10). Fan 7 and Fan 8 are CPU Fans. All
viSUPERSERVER 7046GT-TRF Series User's ManualTable of ContentsChapter 1 Introduction1-1 Overview ...
5-24SUPERSERVER 7046GT-TRF Series User's ManualLAN1/2 (Ethernet Ports) Two Ethernet ports are located next to the USB 2~5 on the IO Backplane. In
Chapter 5: Advanced Serverboard Setup5-25CD1 Pin Defi nition Pin# Defi nition1 Left2 Ground3 Ground4 Right(Back_Panel) High Defi nition Audio (HD Audio
5-26SUPERSERVER 7046GT-TRF Series User's ManualInternal BuzzerThe Internal Buzzer, located at SP1, can be used to provide audible alarms for vari
Chapter 5: Advanced Serverboard Setup5-27Overheat LED/Fan Fail (JOH1)The JOH1 header is used to connect an LED indicator to provide warnings of chas-s
5-28SUPERSERVER 7046GT-TRF Series User's Manual5-9 Jumper SettingsExplanation of JumpersTo modify the operation of the serverboard, jumpers can b
Chapter 5: Advanced Serverboard Setup5-29LAN1/2 Enable/Disable Change the setting of jumper JPL1/JPL2 to enable or disable the LAN1/LAN2 Ethernet port
5-30SUPERSERVER 7046GT-TRF Series User's ManualFP USBWake-up EnableJumper Settings(JPUSB2)Pin# Defi nition1-2 Enabled2-3 Disabled (Default)Bac
Chapter 5: Advanced Serverboard Setup5-31GLAN LEDsThere are two GLAN ports on the motherboard. An additional IPMI dedicated LAN port is also located a
5-32SUPERSERVER 7046GT-TRF Series User's Manual5-11 SATA PortsSerial ATAPin Defi nitions Pin# Defi nition1 Ground2 TX_P3 TX_N4 Ground5 RX_N6 RX_
Chapter 5: Advanced Serverboard Setup5-335-12 Installing SoftwareAfter the hardware has been installed, you should fi rst install the operating system
viiTable of Contents3-3 Control Panel LEDs ... 3-23-4 Drive Car
5-34SUPERSERVER 7046GT-TRF Series User's ManualSupero Doctor IIIThe Supero Doctor III program is a Web base management tool that supports remote
Chapter 5: Advanced Serverboard Setup5-35Note: SD III Software Revision 1.0 can be downloaded from our Web Site at: ftp://ftp.supermicro.com/utility/S
5-36SUPERSERVER 7046GT-TRF Series User's ManualNotes
Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform maintenan
6-2SUPERSERVER 7046GT-TRF Series User's Manual6-1 Static-Sensitive DevicesElectrostatic Discharge (ESD) can damage electronic com ponents. To pre
Chapter 6: Advanced Chassis Setup6-36-3 System CoolingSix heavy-duty fans provide cooling for the chassis. Four fans are located in the mid-section of
6-4SUPERSERVER 7046GT-TRF Series User's ManualRear Fan Release TabFigure 6-4: Rear System Chassis FansFigure 6-3: Mid-System Chassis FansMid FanR
Chapter 6: Advanced Chassis Setup6-56-4 Power SupplyThe SC747 chassis has a 1400W (redundant) power supply. This power supply is auto-switching capabl
6-6SUPERSERVER 7046GT-TRF Series User's ManualPower Supply Cables Name Qty Connects to: Description20-pin or 24-pin power cable1 Motherboard20-pi
Chapter 6: Advanced Chassis Setup6-76-5 Confi guring the the Storage Module This section covers confi guring the storage module in the SC747 chassis.Sto
viiiSUPERSERVER 7046GT-TRF Series User's ManualChapter 6 Advanced Chassis Setup6-1 Static-Sensitive Devices ...
6-8SUPERSERVER 7046GT-TRF Series User's ManualRotating the Storage Module for Rack MountingOpen the chassis cover.1. Locate the storage module an
Chapter 6: Advanced Chassis Setup6-9Figure 6-9: Chassis Storage ModuleTurn the storage module 90 degrees (as illustrated).5. Reinsert the module into
6-10SUPERSERVER 7046GT-TRF Series User's ManualRemoving a Drive CarrierUse the procedure below to add hard drives to the drive carriers.Adding Ha
Chapter 6: Advanced Chassis Setup6-11Hard DriveHard Drive TrayFigure 6-11: Adding a Hard Drive to the Drive CarrierPlace the hard drive to the hard dr
6-12SUPERSERVER 7046GT-TRF Series User's ManualAdding Peripheral DrivesYou can add up to three peripheral drives (DVD-ROM, CD-ROM, fl oppy drive,
Chapter 6: Advanced Chassis Setup6-136-6 Installing Hard Drives in the ChassisChassis hard drives are mounted in drive carriers to simplify their ins
6-14SUPERSERVER 7046GT-TRF Series User's ManualFigure 6-15: Removing a Dummy Drive TrayInsert the hard drive into the chassis. To do this:7. Pres
Chapter 7: BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the AMI BIOS Setup Utility for the X8DTG-QF. The AMI ROM BIOS is stored in a F
7-2SUPERSERVER 7046GT-TRF Series User's ManualStarting the Setup UtilityNormally, the only visible Power-On Self-Test (POST) routine is the memor
Chapter 7: BIOS7-3(Note: The time is in the 24-hour format. For example, 5:30 P.M. appears as 17:30:00.)Supermicro X8DTG-QFBIOS Build Version: This it
Appendix A BIOS Error Beep Codes A-1 BIOS Error Beep Codes ...A-1Append
7-4SUPERSERVER 7046GT-TRF Series User's Manual7-3 Advanced Setup Confi gurationsUse the arrow keys to select the Boot Setup submenu, and hit <
Chapter 7: BIOS7-5Wait For 'F1' If ErrorThis forces the system to wait until the 'F1' key is pressed if an error occurs. The optio
7-6SUPERSERVER 7046GT-TRF Series User's ManualProcessor and Clock OptionsThis submenu allows the user to confi gure the Processor and Clock sett
Chapter 7: BIOS7-7Simultaneous Multi-Threading (Available when supported by the CPU)Set to Enabled to use the Simultaneous Multi-Threading Technology,
7-8SUPERSERVER 7046GT-TRF Series User's ManualAdvanced Chipset ControlThe items included in the Advanced Settings submenu are listed below:CP
Chapter 7: BIOS7-9Throttling - Closed LoopThrottling improves reliability and reduces power in the processor by automatic voltage control during proce
7-10SUPERSERVER 7046GT-TRF Series User's ManualIOH PCIE Max Payload SizeSome add-on cards perform faster with the coalesce feature, which limits
Chapter 7: BIOS7-11Route Port 80h Cycle toUse this item to decide where to route Port 80h Cycle to. The Options are LPC and PCI.IDE/SATA/Floppy Confi
7-12SUPERSERVER 7046GT-TRF Series User's ManualPrimary IDE Master/Slave, Secondary IDE Master/Slave, Third IDE Master, and Fourth IDE MasterThese
Chapter 7: BIOS7-13Select 3 to allow the AMI BIOS to use PIO mode 3. It has a data transfer rate of 11.1 MB/s. Select 4 to allow the AMI BIOS to use P
Komentáře k této Příručce