Supermicro 6016T-NTRF4+ Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Barebone serveru Supermicro 6016T-NTRF4+. Supermicro 6016T-NTRF4+ Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 106
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků

Shrnutí obsahu

Strany 1 - SUPER

SUPERSERVER 6016T-URF4+SUPERSERVER 6016T-NTRF4+ SUPER®USER’S MANUAL1.0

Strany 2 - Release Date: July 21, 2010

1-2SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's Manual1-2 Serverboard FeaturesAt the heart of the SuperServer 6016T-URF4+/6016T-NTRF4+ lies the X8

Strany 3 - Manual Organization

7-28SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualNotes

Strany 4

A-1Appendix A: BIOS Error Beep CodesAppendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the

Strany 5

A-2SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualNotes

Strany 6 - Table of Contents

B-1Appendix B: System Specifi cationsAppendix B System Specifi cationsProcessors Single or dual Intel® 5500/5600 Series processors in LGA1366 soc

Strany 7 - Chapter 4 System Safety

B-2SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualServerboard X8DTU-LN4F+ (Proprietary form factor) Dimensions: 14.85 x 12.68 in

Strany 8

B-3Appendix B: System Specifi cationsRegulatory Compliance Electromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-3, CISPR 22 C

Strany 9 - Introduction

B-4SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualNotes(continued from front)The products sold by Supermicro are not intended for and will not

Strany 10 - 1-2 Serverboard Features

1-3Chapter 1: IntroductionGraphics ControllerThe X8DTU-LN4F+ features an integrated Matrox G200eW graphics chip, which includes 16 MB of DDR2 memory.O

Strany 11 - 1-3 Server Chassis Features

1-4SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualCooling SystemThe SC819TQ-R700U has an innovative cooling design that features fi ve sets of

Strany 12 - Cooling System

1-5Chapter 1: IntroductionFigure 1-1. Intel IOH-36D/ICH10R Chipset: System Block DiagramNote: This is a general block diagram. Please see Chapter 5 f

Strany 13 - System Block Diagram

1-6SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's Manual1-4 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jo

Strany 14 - 1-4 Contacting Supermicro

Chapter 2: Server Installation2-1Chapter 2 Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get your 6016T-URF4+/6016T-

Strany 15 - Server Installation

2-2SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's Manual!!Warnings and Precautions!installation only in a Restricted Access Location (dedicated equi

Strany 16 - Warnings and Precautions!

Chapter 2: Server Installation2-3Rack Mounting ConsiderationsAmbient Operating TemperatureIf installed in a closed or multi-unit rack assembly, the am

Strany 17 - Rack Mounting Considerations

2-4SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's Manual2-4 Installing the System into a RackThis section provides information on installing the 60

Strany 18 - Installing the Inner Rails

Chapter 2: Server Installation2-5Installing the Outer RailsInstalling the Outer Rails to the RackMeasure the distance from the front rail to the rear

Strany 19 - Installing the Outer Rails

The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccur

Strany 20

2-6SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualInstalling the Server into the RackInstalling the Chassis into a Rack (Figure 2-3)Confi rm th

Strany 21

Chapter 2: Server Installation2-7Figure 2-3. Installing the Server into a Rack

Strany 22

2-8SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's Manual2-5 Checking the Serverboard SetupAfter you install the system in the rack, you will need t

Strany 23

Chapter 2: Server Installation2-9Figure 2-4. Accessing the Inside of the System

Strany 24

2-10SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's Manual2-6 Checking the Drive Bay SetupNext, you should check to make sure the peripheral drives

Strany 25 - System Interface

Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are several LEDs on the control panel as well as others on the hard drive ca

Strany 26 - 3-3 Control Panel LEDs

3-2SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualHDDIndicates IDE channel activity. On the 6016T-URF4+/6016T-NTRF4+ this light indi-cates HDD

Strany 27 - 3-4 Drive Carrier LEDs

Chapter 3: System Interface3-3PowerIndicates power is being supplied to the system's power supply units. This LED should normally be illuminated

Strany 28

3-4SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualNotes

Strany 29 - System Safety

Chapter 4: System Safety4-1Chapter 4 System Safety4-1 Electrical Safety Precautions!Basic electrical safety precautions should be followed to protect

Strany 30

iiiPrefacePrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the insta

Strany 31 - 4-3 ESD Precautions

4-2SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's Manual4-2 General Safety PrecautionsFollow these rules to ensure general safety:Keep the area aro

Strany 32 - BATTERY HOLDER

Chapter 4: System Safety4-34-3 ESD PrecautionsElectrostatic Discharge (ESD) is generated by two objects with different electrical charges coming into

Strany 33 - Advanced Serverboard Setup

4-4SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's Manual4-4 Operating PrecautionsCare must be taken to assure that the chassis cover is in place whe

Strany 34 - Installing LGA1366 Processors

Chapter 5: Advanced Serverboard Setup5-1Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to install processors and heatsinks

Strany 35 - Load Plate

5-2SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's Manual5-2 Processor and Heatsink InstallationIMPORTANT! Always connect the power cord last and re

Strany 36 - Installing the Heatsink

Chapter 5: Advanced Serverboard Setup5-3After removing the plastic cap, use 1. your thumb and the index fi nger to hold the CPU at the north and south

Strany 37 - Removing the Heatsink

5-4SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualThermal GreaseCPUPlace the heatsink on top of the 1. CPU so that the four mounting holes are

Strany 38 - 5-3 Connecting Cables

Chapter 5: Advanced Serverboard Setup5-5Unplug the power cord from the power supply.1. Unscrew and remove the heatsink screws in the 1. sequence shown

Strany 39 - 5-4 I/O Ports

5-6SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's Manual5-3 Connecting CablesNow that the processors are installed, the next step is to connect the

Strany 40 - 5-5 Installing Memory

Chapter 5: Advanced Serverboard Setup5-7Figure 5-1. Front Control Panel Header Pins (JF1)See the Connector Defi nitions section in this chapter for det

Strany 41

SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualivChapter 5: Advanced Serverboard SetupChapter 5 provides detailed information on the X8DTU-LN

Strany 42

5-8SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's Manual5-5 Installing MemoryNote: Check the Supermicro web site for recommended memory modules.CAUT

Strany 43 - 1.35V DIMMs•

Chapter 5: Advanced Serverboard Setup5-9Memory Support for 5500 Processor(s)RDIMM Population w/5500 Processors InstalledDIMM Slots per ChannelDIMMs Po

Strany 44 - 5-6 Adding PCI Cards

5-10SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualNotes: Memory speed support depends on the type of CPU used. Due to OS limita-tions, some o

Strany 45 - 5-7 Serverboard Details

Chapter 5: Advanced Serverboard Setup5-11Possible System Memory Allocation & AvailabilitySystem Device Size Physical Memory Remaining (4 GB Total

Strany 46 - X8DTU-LN4F+ Quick Reference

5-12SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's Manual6016T-URF4+ PCI Slot/Card Confi gurationsRiser Card Expansion Card SupportedRSC-R1UU-UE16 (l

Strany 47 - 5-8 Connector Defi nitions

Chapter 5: Advanced Serverboard Setup5-13Figure 5-4. SUPER X8DTU-LN4F+ Layout5-7 Serverboard DetailsNotes:Jumpers not indicated are for test purposes

Strany 48

5-14SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualX8DTU-LN4F+ Quick ReferenceJumper Description Default SettingJBT1 Clear CMOS See Section 5-

Strany 49

Chapter 5: Advanced Serverboard Setup5-155-8 Connector Defi nitionsPower LED The Power LED connection is located on pins 15 and 16 of JF1. Refer to the

Strany 50 - Pin # Defi nition

5-16SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualNIC1 LEDThe NIC1 (Network Interface Control-ler) LED connection is located on pins 11 and 1

Strany 51

Chapter 5: Advanced Serverboard Setup5-17Reset Button The Reset Button connection is lo-cated on pins 3 and 4 of JF1. Attach it to the hardware reset

Strany 52

vPrefaceNotes

Strany 53

5-18SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualFan HeadersThe X8DTU-LN4F+ has eight fan headers, designated Fan1 through Fan8. FAN1 throug

Strany 54

Chapter 5: Advanced Serverboard Setup5-19ATX PS/2 Keyboard and PS/2 Mouse PortsThe ATX PS/2 keyboard and the PS/2 mouse ports are located beside the U

Strany 55 - 5-9 Jumper Settings

5-20SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualLAN1/2/3/4 (Ethernet Ports)Four Ethernet ports (designated LAN1, LAN2, LAN3 and LAN4) are l

Strany 56

Chapter 5: Advanced Serverboard Setup5-21NIC3/NIC4 LED HeadersA LAN3 (NIC3) LED and LAN4 (NIC4) LED header is located at JPK1. Con-nect the appropriat

Strany 57 - 5-10 Onboard Indicators

5-22SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualTrusted Platform Module HeaderA Trusted Platform Module (TPM) header (JTPM) is located next

Strany 58 - Blinking BMC: Normal

Chapter 5: Advanced Serverboard Setup5-235-9 Jumper SettingsExplanation of JumpersTo modify the operation of the serverboard, jumpers can be used to c

Strany 59 - 5-12 Installing Software

5-24SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualLAN1/LAN2 Enable/Disable Change the setting of jumper JPL1 and/or JPL2 to enable or disable

Strany 60 - Supero Doctor III

Chapter 5: Advanced Serverboard Setup5-255-10 Onboard IndicatorsLAN LEDsThe Ethernet ports (located beside the VGA port) have two LEDs. On each Gigabi

Strany 61

5-26SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's Manual5-11 SATA Port ConnectionsSATA PortsSee the table on the right for pin defi nitions for the

Strany 62

Chapter 5: Advanced Serverboard Setup5-275-12 Installing SoftwareAfter the hardware has been installed, you should fi rst install the operating system

Strany 63 - Advanced Chassis Setup

viSUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualTable of ContentsChapter 1 Introduction1-1 Overview ...

Strany 64 - 6-2 Control Panel

5-28SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualSupero Doctor IIIThe Supero Doctor III program is a Web base management tool that supports

Strany 65 - 6-3 System Fans

Chapter 5: Advanced Serverboard Setup5-29Note: SD III Software Revision 1.0 can be downloaded from our Web Site at: ftp://ftp.supermicro.com/utility/S

Strany 66 - Accessing the Drive Bays

5-30SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualNotes

Strany 67 - Hard Drive Installation

Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform mainte-na

Strany 68 - Hard Drive Backplane

6-2SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualFigure 6-1. Chassis: Front and Rear Views6-2 Control PanelThe control panel (located on the

Strany 69 - DVD-ROM Drive Installation

Chapter 6: Advanced Chassis Setup6-36-3 System FansFive 4-cm heavy duty counter-rotating fans provide the cooling for the 6016T-URF4+/6016T-NTRF4+. Ea

Strany 70 - 6-4 Power Supply

6-4SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualFigure 6-2. System Cooling FansAccessing the Drive BaysSATA Drives: Because of their hotswa

Strany 71

Chapter 6: Advanced Chassis Setup6-5Hard Drive InstallationThe hard drives are mounted in drive carriers to simplify their installation and removal fr

Strany 72

6-6SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualInstalling/Removing a Hard DriveTo remove a carrier, push the release button located beside

Strany 73 - Chapter 7

Chapter 6: Advanced Chassis Setup6-7DVD-ROM Drive InstallationThe top cover of the chassis must be opened to gain full access to the DVD-ROM drive bay

Strany 74 - 7-2 Main Setup

viiTable of ContentsChapter 3 System Interface3-1 Overview ...

Strany 75

6-8SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's Manual6-4 Power SupplyThe SuperServer 6016T-URF4+/6016T-NTRF4+ has a 700 watt redundant power supp

Strany 76 - XBoot Features

Chapter 6: Advanced Chassis Setup6-9Figure 6-5. Removing/Replacing the Power Supply

Strany 77 - Processor and Clock Options

6-10SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualNotes

Strany 78

Chapter 7: BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the AMI BIOS Setup Utility for the X8DTU-LN4F+. The AMI ROM BIOS is stored in

Strany 79

7-2SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualStarting the Setup UtilityNormally, the only visible Power-On Self-Test (POST) routine is th

Strany 80 - XCPU Bridge Confi guration

Chapter 7: BIOS7-3System Overview: The following BIOS information will be displayed:System Time/System Date Use this option to change the system time

Strany 81 - XNorth Bridge Confi guration

7-4SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's Manual7-3 Advanced Setup Confi gurationsUse the arrow keys to select Boot Setup and hit <Enter&

Strany 82 - XSouth Bridge Confi guration

Chapter 7: BIOS7-5Hit 'Del' Message DisplayThis feature displays "Press DEL to run Setup" during POST. The options are Enabled and

Strany 83 - IDE/SATA Confi guration

7-6SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualClock Spread SpectrumSelect Enable to use the feature of Clock Spectrum, which will allow th

Strany 84

Chapter 7: BIOS7-7Simultaneous Multi-Threading (Available when supported by the CPU)Set to Enabled to use the Simultaneous Multi-Threading Technology,

Strany 85

viiiSUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's Manual5-11 SATA Port Connections ...

Strany 86 - XPCI/PnP Confi guration

7-8SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualXAdvanced Chipset ControlThe items included in the Advanced Settings submenu are listed belo

Strany 87 - XRemote Access Confi guration

Chapter 7: BIOS7-9Memory Mode The options are Independent, Channel Mirror, and Lockstep.Independent - All DIMMs are available to the operating system.

Strany 88 - Hardware Health Monitor

7-10SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualIntel I/OATThe Intel I/OAT (I/O Acceleration Technology) signifi cantly reduces CPU overhead

Strany 89

Chapter 7: BIOS7-11USB FunctionsThis feature allows the user to decide the number of onboard USB ports to be en-abled. The Options are: Disabled, 2 US

Strany 90

7-12SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualICH AHCI Codebase (Available when the option-AHCI is selected.)Use this feature to select t

Strany 91 - XACPI Confi guration

Chapter 7: BIOS7-13Select Auto to allow the AMI BIOS to automatically detect the PIO mode. Use this value if the IDE disk drive support cannot be dete

Strany 92 - XTrusted Computing

7-14SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualSelect UDMA2 to allow the BIOS to use Ultra DMA mode 2. It has a data transfer rate of 33.3

Strany 93 - View BMC System Event Log

Chapter 7: BIOS7-15SXB1 PCI-E 2.0 x16/x8 Option ROM/SXB3 PCI-E 2.0 x8 Option ROM/SXB2 PCI-E 2.0 x8/x4 Option ROM/SXB2 PCI-E 2.0 x4 Option ROMSelect En

Strany 94 - Set LAN Confi guration

7-16SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualSerial Port NumberThis feature allows the user decide which serial port to be used for Cons

Strany 95 - XDMI Event Log Confi guration

Chapter 7: BIOS7-17CPU Overheat AlarmThis option allows the user to select the CPU Overheat Alarm setting which de-termines when the CPU OH alarm will

Strany 96 - 7-4 Security Settings

Chapter 1 Introduction1-1 OverviewThe SuperServer 6016T-URF4+/6016T-NTRF4+ is a high-end server comprised of two main subsystems: the SC819TQ-R700U 1U

Strany 97 - 7-5 Boot Confi guration

7-18SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's Manualseeing a temperature reading (i.e., 25oC). The CPU Temperature feature will display the CPU

Strany 98 - 7-6 Exit Options

Chapter 7: BIOS7-19Select "Balanced/BL" for the onboard fans to run at a speed that will balance the needs between system cooling and power

Strany 99

7-20SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's ManualNUMA SupportSelect Enabled to use the feature of Non-Uniform Memory Access to improve CPU p

Strany 100

Chapter 7: BIOS7-21TPM Owner StatusThis item displays the status of TPM Ownership.XIPMI Confi gurationIntelligent Platform Management Interface (IPMI)

Strany 101 - BIOS Error Beep Codes

7-22SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's Manual Event Data.• Clear BMC System Event LogClear BMC System Log nowSelect OK and press the <

Strany 102

Chapter 7: BIOS7-23Gateway Address (When IP Address Source is set to 'Static') The BIOS will automatically enter the Gateway address of this

Strany 103 - System Specifi cations

7-24SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's Manual7-4 Security SettingsThe AMI BIOS provides a Supervisor and a User password. If you use bot

Strany 104

Chapter 7: BIOS7-25Clear User Password (Available only when User Password has been set)This item allows you to clear a user password after it has been

Strany 105 - Regulatory Compliance

7-26SUPERSERVER 6016T-URF4+/6016T-NTRF4+ User's Manual1st Drive - [RAID: XXXXXXXXX]• Retry Boot DevicesSelect Enabled to enable Retry Boot Device

Strany 106

Chapter 7: BIOS7-27Load Optimal DefaultsTo set this feature, select Load Optimal Defaults from the Exit menu and press <Enter>. Then, select OK

Komentáře k této Příručce

Žádné komentáře