®SUPERSERVER 6026T-NTR+ SUPERUSER’S MANUAL1.0
1-2SUPERSERVER 6026T-NTR+ User's Manual1-2 Serverboard FeaturesAt the heart of the SuperServer 6026T-NTR+ lies the X8DTN+, a dual processor serve
C-2SUPERSERVER 6026T-NTR+ User's ManualServerboard X8DTN+ (Extended ATX form factor) Dimensions: 13.68 x 13.05 in (348 x 332 mm)Cha
C-3Appendix C: System Specifi cationsCalifornia Best Management Practices Regulations for Perchlorate Materials: This Perchlorate warning applies only
C-4SUPERSERVER 6026T-NTR+ User's Manual(continued from front)The products sold by Supermicro are not intended for and will not be used in life su
1-3Chapter 1: IntroductionOnboard Controllers/PortsA fl oppy drive connector is included on the serverboard as well as one onboard ATA/100 connector,
1-4SUPERSERVER 6026T-NTR+ User's ManualFront Control PanelThe control panel on the SuperServer 6026T-NTR+ provides you with system monitoring and
1-5Chapter 1: IntroductionFigure 1-1. Intel 5520/ICH10R Chipset: System Block DiagramNote: This is a general block diagram. Please see Chapter 5 for
1-6SUPERSERVER 6026T-NTR+ User's Manual1-4 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131
Chapter 2: Server Installation2-1Chapter 2 Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get your SuperServer 6026T-
2-2SUPERSERVER 6026T-NTR+ User's ManualThis product is for installation only in a Restricted Access Location (dedicated • equipment rooms, servic
Chapter 2: Server Installation2-3Rack Mounting ConsiderationsAmbient Operating TemperatureIf installed in a closed or multi-unit rack assembly, the am
2-4SUPERSERVER 6026T-NTR+ User's Manual2-4 Installing the System into a RackThis section provides information on installing the SC825 chassis in
Chapter 2: Server Installation2-5Figure 2-1. Separating the Rack Rails 11121413Separating the Inner and Outer RailsLocate the rail assembly in the ch
Manual Revision 1.0 Release Date: April 21, 2009The information in this User’s Manual has been carefully reviewed and is believed to be accurate
2-6SUPERSERVER 6026T-NTR+ User's ManualOuter Rack RailsOuter rails attach to the rack and hold the chassis in place. The outer rails for the SC82
Chapter 2: Server Installation2-7Figure 2-3. Installing the Rack RailsInstalling the Chassis into a RackExtend the outer rails as illustrated above.
2-8SUPERSERVER 6026T-NTR+ User's Manual2-5 Checking the Serverboard SetupAfter you install the 6026T-NTR+ in the rack, you will need to open the
Chapter 2: Server Installation2-9Figure 2-3. Accessing the Inside of the System
2-10SUPERSERVER 6026T-NTR+ User's Manual2-6 Checking the Drive Bay SetupNext, you should check to make sure the peripheral drives and the SATA d
Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are several LEDs on the control panel as well as others on the SATA drive ca
SUPERSERVER 6026T-NTR+ User's Manual3-2123-3 Control Panel LEDsThe control panel located on the front of the chassis has several LEDs. These LED
Chapter 3: System Interface3-3HDDIndicates IDE channel activity. On the SuperServer 6026T-NTR+, this LED indicates hard drive and/or DVD-ROM drive act
SUPERSERVER 6026T-NTR+ User's Manual3-4Notes
Chapter 4: System Safety4-1Chapter 4 System Safety4-1 Electrical Safety Precautions!Basic electrical safety precautions should be followed to protect
iiiPrefacePrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the insta
SUPERSERVER 6026T-NTR+ User's Manual4-24-2 General Safety PrecautionsFollow these rules to ensure general safety:Keep the area around the 6026T-
Chapter 4: System Safety4-34-3 ESD PrecautionsElectrostatic discharge (ESD) is generated by two objects with different electrical charges coming into
SUPERSERVER 6026T-NTR+ User's Manual4-44-4 Operating PrecautionsCare must be taken to assure that the chassis cover is in place when the 6026T-NT
Chapter 5: Advanced Serverboard Setup5-1Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to install the X8DTN+ serverboard i
5-2SUPERSERVER 6026T-NTR+ User's ManualUnpackingThe serverboard is shipped in antistatic packaging to avoid electrical static dis-charge. When un
Chapter 5: Advanced Serverboard Setup5-35-3 Connecting CablesNow that the serverboard is installed, the next step is to connect the cables to the boar
5-4SUPERSERVER 6026T-NTR+ User's Manual5-4 I/O PortsThe I/O ports are color coded in conformance with the PC 99 specifi cation. See Figure 5-2 be
Chapter 5: Advanced Serverboard Setup5-5!Press the socket clip to release 1. the load plate, which covers the CPU socket, from its locked posi-tion.Ge
5-6SUPERSERVER 6026T-NTR+ User's ManualAfter removing the plastic cap, use 1. your thumb and the index fi nger to hold the CPU at the north and so
Chapter 5: Advanced Serverboard Setup5-7Thermal GreaseCPUPlace the heatsink on top of the 1. CPU so that the four mounting holes are aligned with thos
SUPERSERVER 6026T-NTR+ User's ManualivChapter 5: Advanced Serverboard SetupChapter 5 provides detailed information on the X8DTN+ serverboard, in
5-8SUPERSERVER 6026T-NTR+ User's ManualUnplug the power cord from the power supply.1. Unscrew and remove the heatsink screws in the 1. sequence s
Chapter 5: Advanced Serverboard Setup5-9Memory SupportThe X8DTN+ supports up to 144 GB of DDR3 1333/1066/800 registered ECC SDRAM in 18 DIMM slots. Th
5-10SUPERSERVER 6026T-NTR+ User's ManualMemory SupportThe X8DTN+ supports up to 144 GB Registered ECC DDR3-1333/1066/800 MHz registered ECC SDRAM
Chapter 5: Advanced Serverboard Setup5-115-7 Installing PCI Add-On CardsThe 6026T-NTR+ can accommodate seven low-profi le, full-length PCI add-on card
5-12SUPERSERVER 6026T-NTR+ User's ManualFigure 5-4. X8DTN+ Layout(not drawn to scale)5-8 Serverboard DetailsJPL1J21JF1JPW4JPW3JPW1SpeakerFan1Fan4
Chapter 5: Advanced Serverboard Setup5-13X8DTN+ Quick ReferenceJumper Description Default SettingJBT1 CMOS Clear See Section 5-10J12 SMB to PCI-Exp. S
5-14SUPERSERVER 6026T-NTR+ User's ManualReset ButtonThe Reset Button connection is located on pins 3 and 4 of JF1 and attaches to the reset switc
Chapter 5: Advanced Serverboard Setup5-15Overheat/Fan Fail LED (OH)Connect an LED to the OH connection on pins 7 and 8 of JF1 to provide ad-vanced war
5-16SUPERSERVER 6026T-NTR+ User's ManualFan HeadersThere are eight fan headers on the serverboard, all of which are 4-pin fans. Pins 1-3 of the f
Chapter 5: Advanced Serverboard Setup5-17Wake-On-LANThe Wake-On-LAN header is des-ignated JWOL1 on the serverboard. See the table on the right for pin
NotesPrefacev
5-18SUPERSERVER 6026T-NTR+ User's ManualSerial PortsTwo serial ports are included on the serverboard. COM1 is a backpanel port and COM2 is a head
Chapter 5: Advanced Serverboard Setup5-19Power I2C ConnectorThe power System Management Bus (I2C) connector monitors the status of the power supply, f
5-20SUPERSERVER 6026T-NTR+ User's Manual5-10 Jumper SettingsExplanation of JumpersTo modify the operation of the serverboard, jumpers can be used
Chapter 5: Advanced Serverboard Setup5-21CMOS ClearJBT1 is used to clear CMOS (which will also clear any passwords). Instead of pins, this jumper con
5-22SUPERSERVER 6026T-NTR+ User's ManualI2C to PCI-X/PCI-E SlotsJumper Settings (J12/J13)Jumper Setting Defi nition JI2C1: Closed JI2C2:Cl
Chapter 5: Advanced Serverboard Setup5-235-11 Onboard IndicatorsLAN1/2 LEDsThe Ethernet ports (located beside the VGA port) have two LEDs. On each por
5-24SUPERSERVER 6026T-NTR+ User's Manual5-12 Floppy, IDE and SATA PortsUse the following information to connect the IDE hard disk drive cables.A
Chapter 5: Advanced Serverboard Setup5-25SATA PortsThere are no jumpers to confi gure the onboard SATA connectors. See the table on the right for pin d
5-26SUPERSERVER 6026T-NTR+ User's Manual5-13 Installing SoftwareAfter the hardware has been installed, you should fi rst install the operating sys
Chapter 5: Advanced Serverboard Setup5-27Supero Doctor IIIThe Supero Doctor III program is a Web base management tool that supports remote management
viTable of ContentsChapter 1 Introduction1-1 Overview ...
5-28SUPERSERVER 6026T-NTR+ User's ManualNote: SD III Software Revision 1.0 can be downloaded from our Web Site at: ftp://ftp.supermicro.com/utili
Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform mainte-na
6-2SUPERSERVER 6026T-NTR+ User's ManualFigure 6-1. Front and Rear Chassis ViewsSystem Reset6-2 Control PanelThe control panel (located on the fr
Chapter 6: Advanced Chassis Setup6-36-3 System FansThree 8-cm hot-swap fans provide the cooling for the system. It is very important that the chassis
6-4SUPERSERVER 6026T-NTR+ User's ManualFigure 6-2. Removing System Cooling Fans6-4 Drive Bay Installation/RemovalAccessing the Drive BaysSATA D
Chapter 6: Advanced Chassis Setup6-5SATA Drive InstallationThe SATA drives are mounted in drive carriers to simplify their installation and removal fr
6-6SUPERSERVER 6026T-NTR+ User's ManualFigure 6-4. Removing a SATA Drive Carrier!Important: All of the drive carriers must remain in the drive b
Chapter 6: Advanced Chassis Setup6-7DVD-ROM and Floppy Drive InstallationThe top cover of the chassis must be opened to gain full access to the DVD-RO
6-8SUPERSERVER 6026T-NTR+ User's Manual6-5 Power SupplyThe SuperServer 6026T-NTR+ has a 720 watt redundant power supply consisting of two power m
Chapter 7: BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the AMI BIOS Setup Utility for the X8DTN+. The AMI ROM BIOS is stored in a Fla
vii2-6 Checking the Drive Bay Setup ... 2-10Chapter 3 System Interface3-1 Overview
7-2SUPERSERVER 6026T-NTR+ User's ManualStarting the Setup UtilityNormally, the only visible Power-On Self-Test (POST) routine is the memory test.
Chapter 7: BIOS7-3Supermicro X8DTN+BIOS Build Version• : This item displays the BIOS revision used in your sys-tem.BIOS Build Date• : This item disp
7-4SUPERSERVER 6026T-NTR+ User's Manual7-3 Advanced Setup Confi gurationsUse the arrow keys to select Boot Setup and hit <Enter> to access
Chapter 7: BIOS7-5Hit 'Del' Message DisplayThis feature displays "Press DEL to run Setup" during POST. The options are Enabled and
7-6SUPERSERVER 6026T-NTR+ User's ManualC1E SupportSelect Enabled to use the feature of Enhanced Halt State. C1E signifi cantly reduces the CPU&apo
Chapter 7: BIOS7-7tion and heat dissipation. Please refer to Intel’s web site for detailed information. The options are Disable (Disable GV3) and Ena
7-8SUPERSERVER 6026T-NTR+ User's ManualQPI L0s and L1This enables the QPI power state to low power. L0s and L1 are automatically selected by the
Chapter 7: BIOS7-9Guardband Temperature (Available for Closed Loop only)This is the temperature which applies to the DIMM temperature threshold. Each
7-10SUPERSERVER 6026T-NTR+ User's Manualprocessor that is installed on an add-on card or a network card to handle some or all packet processing o
Chapter 7: BIOS7-11BIOS EHCI Hand-OffSelect Enabled to enable BIOS Enhanced Host Controller Interface support to provide a workaround solution for an
viii5-8 Serverboard Details ... 5-12X8DTN+ Quick Reference ...
7-12SUPERSERVER 6026T-NTR+ User's ManualICH RAID Code Base (This feature is available when the option-RAID is selected)Select Intel to enable Int
Chapter 7: BIOS7-13PIO ModeThe IDE PIO (Programmable I/O) Mode programs timing cycles between the IDE drive and the programmable IDE controller. As th
7-14SUPERSERVER 6026T-NTR+ User's ManualSelect UDMA2 to allow the BIOS to use Ultra DMA mode 2. It has a data transfer rate of 33.3 MBs. Select U
Chapter 7: BIOS7-15PCI Latency TimerThis feature sets the latency Timer of each PCI device installed on a PCI bus. Select 64 to set the PCI latency to
7-16SUPERSERVER 6026T-NTR+ User's ManualSerial Port NumberThis feature allows the user decide which serial port to be used for Console Redi-recti
Chapter 7: BIOS7-17CPU Overheat AlarmThis option allows the user to select the CPU Overheat Alarm setting which de-termines when the CPU OH alarm will
7-18SUPERSERVER 6026T-NTR+ User's Manualseeing a temperature reading (i.e., 25oC). The CPU Temperature feature will display the CPU temperature s
Chapter 7: BIOS7-19Voltages ReadingsThe following voltage readings will be displayed.CPU1 Vcore, CPU2 Vcore, +5Vin, +12V, -12V 3.3Vcc (V), and Battery
7-20SUPERSERVER 6026T-NTR+ User's ManualTPM Enable/Disable StatusThis item displays the status of TPM Support to indicate if TPM is currently ena
Chapter 7: BIOS7-21Clear BMC System Event LogSelect OK and press the <Enter> key to clear the BMC system log. Select Cancel to keep the BMC Syst
Chapter 1 Introduction1-1 OverviewThe SuperServer 6026T-NTR+ is a high-end server comprised of two main subsys-tems: the SC825TQ-R720LPB 2U server cha
7-22SUPERSERVER 6026T-NTR+ User's ManualParameter SelectorUse this feature to select the parameter of your Mac Address confi guration.Mac Address
Chapter 7: BIOS7-23PEF Alert Startup Delay (Available if the item-PEF Support is enabled)This sets the pre-determined time to delay PEF alerts after s
7-24SUPERSERVER 6026T-NTR+ User's Manual7-4 Security SettingsThe AMIBIOS Setup Utility provides a Supervisor and a User password. If you use both
Chapter 7: BIOS7-257-5 Boot Confi gurationUse this feature to confi gure boot settings. XBoot Device PriorityThis feature allows the user to specify the
7-26SUPERSERVER 6026T-NTR+ User's Manual7-6 Exit OptionsSelect the Exit tab from the AMI BIOS Setup Utility screen to enter the Exit BIOS Setup s
A-1Appendix A: BIOS Error Beep CodesAppendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the
A-2SUPERSERVER 6026T-NTR+ User's ManualNotes
Appendix B: Installing Windows B-1Appendix B Installing WindowsAfter all hardware components have been installed, you must fi rst confi gure Intel South
B-2SUPERSERVER 6026T-NTR+ User's ManualB-2 Installing Windows to a Non-RAID SystemInsert Microsoft's Windows XP/Windows 2003/Windows 2008/W
C-1Appendix C: System Specifi cationsAppendix C System Specifi cationsProcessors Single or dual Intel® Xeon® 5500 processors (both CPUs must be o
Komentáře k této Příručce