®SUPERSERVER 7046T-NTR+ SUPERUSER’S MANUAL1.0
1-2SUPERSERVER 7046T-NTR+ User's Manual1-2 Serverboard FeaturesAt the heart of the SuperServer 7046T-NTR+ lies the X8DTN+, a dual processor serve
A-2SUPERSERVER 7046T-NTR+ User's ManualNotes
Appendix B: Installing Windows B-1Appendix B Installing WindowsAfter all hardware components have been installed, you must fi rst confi gure Intel South
B-2SUPERSERVER 7046T-NTR+ User's ManualB-2 Installing Windows to a Non-RAID SystemInsert Microsoft's Windows Setup CD in the CD drive and t
C-1Appendix C: System Specifi cationsAppendix C System Specifi cationsProcessors Single or dual Intel® Xeon® 5500 processors (both CPUs must be o
C-2SUPERSERVER 7046T-NTR+ User's ManualChassis SC745TQ-R800B, tower/4U rackmount Dimensions (as tower): (WxHxD) 7 x 19 x 27 in. (17
C-3Appendix C: System Specifi cationsNotes
C-4SUPERSERVER 7046T-NTR+ User's Manual(continued from front)The products sold by Supermicro are not intended for and will not be used in life su
1-3Chapter 1: IntroductionOnboard Controllers/PortsA fl oppy drive connector is included on the serverboard as well as one onboard ATA/100 connector,
1-4SUPERSERVER 7046T-NTR+ User's ManualI/O BackplaneThe SC745TQ-R800B is an Extended ATX form factor chassis that may be used in either a tower o
1-5Chapter 1: IntroductionFigure 1-1. Intel 5520/ICH10R Chipset: System Block DiagramNote: This is a general block diagram. Please see Chapter 5 for
1-6SUPERSERVER 7046T-NTR+ User's Manual1-4 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131
Chapter 2: Server Installation2-1Chapter 2 Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get your SuperServer 7046T-
2-2SUPERSERVER 7046T-NTR+ User's Manual!!Warnings and Precautions!Choosing a Setup LocationLeave enough clearance in front of the rack to enable
Chapter 2: Server Installation2-3Allow the hot plug SATA drives and power supply modules to cool before touch-• ing them.Always keep the rack's f
2-4SUPERSERVER 7046T-NTR+ User's Manual2-4 Installing the System into a RackThis section provides information on installing the system into a ra
Chapter 2: Server Installation2-5Installing the Chassis RailsYou will need to remove the top cover and the feet to add rack rails to the chassis. Firs
Manual Revision 1.0 Release Date: May 22, 2009The information in this User’s Manual has been carefully reviewed and is believed to be accurate.
2-6SUPERSERVER 7046T-NTR+ User's ManualInstalling the Rack RailsDetermine where you want to place the SuperServer 7046T-NTR+ in the rack. (See Ra
Chapter 2: Server Installation2-7Figure 2-4. Installing the Server into a RackInstalling the Server into the RackYou should now have rails attached t
2-8SUPERSERVER 7046T-NTR+ User's Manual2-5 Checking the Serverboard SetupAfter setting up the the system, you will need to open the unit to make
Chapter 2: Server Installation2-92-6 Checking the Drive Bay SetupNext, you should check to make sure the peripheral drives and then SATA drives and b
2-10SUPERSERVER 7046T-NTR+ User's ManualFigure 2-5. Accessing the Inside of the System (Rack Confi guration shown)
Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThe control panel on the 7046T-NTR+ has several LEDs and two buttons. There are al
3-2SUPERSERVER 7046T-NTR+ User's Manual3-3 Control Panel LEDsThe control panel located on the front of the SC745 chassis has six LEDs that provi
Chapter 3: System Interface3-3Overheat/Fan FailWhen this LED fl ashes, it indicates a fan failure. When on continuously it indicates an overheat condit
3-4SUPERSERVER 7046T-NTR+ User's ManualNotes
Chapter 4: System Safety4-1Chapter 4 System Safety4-1 Electrical Safety Precautions!Basic electrical safety precautions should be followed to protect
iiiPrefacePrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the insta
SUPERSERVER 7046T-NTR+ User's Manual4-24-2 General Safety PrecautionsFollow these rules to ensure general safety:Keep the area around the 7046T-
Chapter 4: System Safety4-34-3 ESD PrecautionsElectrostatic Discharge (ESD) is generated by two objects with different electrical charges coming into
SUPERSERVER 7046T-NTR+ User's Manual4-44-4 Operating PrecautionsCare must be taken to assure that the chassis cover is in place when the 7046T-NT
Chapter 5: Advanced Serverboard Setup5-1Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to install the X8DTN+ serverboard i
5-2SUPERSERVER 7046T-NTR+ User's ManualUnpackingThe serverboard is shipped in antistatic packaging to avoid electrical static dis-charge. When un
Chapter 5: Advanced Serverboard Setup5-35-3 Connecting CablesNow that the serverboard is installed, the next step is to connect the cables to the boar
5-4SUPERSERVER 7046T-NTR+ User's Manual5-4 I/O PortsThe I/O ports are color coded in conformance with the PC 99 specifi cation. See Figure 5-2 be
Chapter 5: Advanced Serverboard Setup5-5!Press the socket clip to release 1. the load plate, which covers the CPU socket, from its locked posi-tion.Ge
5-6SUPERSERVER 7046T-NTR+ User's ManualAfter removing the plastic cap, use 1. your thumb and the index fi nger to hold the CPU at the north and so
Chapter 5: Advanced Serverboard Setup5-7Remove power from the system 1. and unplug the AC power cord from the power supply.Do not apply any thermal gr
SUPERSERVER 7046T-NTR+ User's ManualivChapter 5: Advanced Serverboard SetupChapter 5 provides detailed information on the X8DTN+ serverboard, in
5-8SUPERSERVER 7046T-NTR+ User's ManualMemory SupportThe X8DTN+ supports up to 144 GB of DDR3 1333/1066/800 registered ECC SDRAM in 18 DIMM slots
Chapter 5: Advanced Serverboard Setup5-9Memory SupportThe X8DTN+ supports up to 144 GB Registered ECC DDR3-1333/1066/800 MHz registered ECC SDRAM in 1
5-10SUPERSERVER 7046T-NTR+ User's Manual5-7 Installing PCI Expansion CardsThe 7046T-NTR+ can accommodate standard size add-on cards installed in
Chapter 5: Advanced Serverboard Setup5-11Figure 5-4. X8DTN+ Layout(not drawn to scale)5-8 Serverboard DetailsJPL1J21JF1JPW4JPW3JPW1SpeakerFan1Fan4Fan8
5-12SUPERSERVER 7046T-NTR+ User's ManualX8DTN+ Quick ReferenceJumper Description Default SettingJBT1 CMOS Clear See Section 5-10J12 SMB to PCI-Ex
Chapter 5: Advanced Serverboard Setup5-13Reset ButtonThe Reset Button connection is located on pins 3 and 4 of JF1 and attaches to the reset switch on
5-14SUPERSERVER 7046T-NTR+ User's ManualOverheat/Fan Fail LED (OH)Connect an LED to the OH connection on pins 7 and 8 of JF1 to provide ad-vanced
Chapter 5: Advanced Serverboard Setup5-15Fan HeadersThere are eight fan headers on the serverboard, all of which are 4-pin fans. Pins 1-3 of the fan h
5-16SUPERSERVER 7046T-NTR+ User's ManualWake-On-LANThe Wake-On-LAN header is des-ignated JWOL1 on the serverboard. See the table on the right for
Chapter 5: Advanced Serverboard Setup5-17Serial PortsTwo serial ports are included on the serverboard. COM1 is a backpanel port and COM2 is a header l
NotesPrefacev
5-18SUPERSERVER 7046T-NTR+ User's ManualPower I2C ConnectorThe power System Management Bus (I2C) connector monitors the status of the power suppl
Chapter 5: Advanced Serverboard Setup5-195-10 Jumper SettingsExplanation of JumpersTo modify the operation of the serverboard, jumpers can be used to
5-20SUPERSERVER 7046T-NTR+ User's ManualCMOS ClearJBT1 is used to clear CMOS (which will also clear any passwords). Instead of pins, this jumper
Chapter 5: Advanced Serverboard Setup5-21I2C to PCI-X/PCI-E SlotsJumper Settings (J12/J13)Jumper Setting Defi nition JI2C1: Closed JI2C2:Closed
5-22SUPERSERVER 7046T-NTR+ User's Manual5-11 Onboard IndicatorsLAN1/2 LEDsThe Ethernet ports (located beside the VGA port) have two LEDs. On each
Chapter 5: Advanced Serverboard Setup5-235-12 Floppy, IDE and SATA PortsUse the following information to connect the IDE hard disk drive cables.A red
5-24SUPERSERVER 7046T-NTR+ User's ManualSATA PortsThere are no jumpers to confi gure the onboard SATA connectors. See the table on the right for p
Chapter 5: Advanced Serverboard Setup5-255-13 Installing SoftwareAfter the hardware has been installed, you should fi rst install the operating system
5-26SUPERSERVER 7046T-NTR+ User's ManualSupero Doctor IIIThe Supero Doctor III program is a Web based management tool that supports remote manage
Chapter 5: Advanced Serverboard Setup5-27Note: SD III Software Revision 1.0 can be downloaded from our Web Site at: ftp://ftp.supermicro.com/utility/S
viTable of ContentsChapter 1 Introduction1-1 Overview ...
5-28SUPERSERVER 7046T-NTR+ User's ManualNotes
Chapter 6: Advanced Chassis Setup6-1Chapter 6Advanced Chassis SetupThis chapter covers the steps required to install components and perform simple mai
6-2SUPERSERVER 7046T-NTR+ User's ManualFigure 6-1. Chassis Front ViewSystem ResetMain Power 5.25" Drive Bays (2)USB Ports8 SATA Drive Bays
Chapter 6: Advanced Chassis Setup6-36-2 Front Control PanelThe front control panel must be connected to the JF1 connector on the serverboard to provi
6-4SUPERSERVER 7046T-NTR+ User's Manual6-3 System FansThree 8-cm chassis cooling fans (located in the center of the chassis) provide cool-ing air
Chapter 6: Advanced Chassis Setup6-5Figure 6-4. Removing the Air ShroudFigure 6-3. Removing a Chassis Fan
6-6SUPERSERVER 7046T-NTR+ User's ManualInstalling/Removing SATA DrivesTo remove a carrier, fi rst open the front bezel.1. Push the release button
Chapter 6: Advanced Chassis Setup6-7Figure 6-6. Mounting a SATA Drive in a Carrier!Important! Use extreme caution when working around the SATA backpl
6-8SUPERSERVER 7046T-NTR+ User's ManualInstalling Components in the 5.25" Drive BaysThe 7046T-NTR+ has two 5.25" drive bays. Components
Chapter 6: Advanced Chassis Setup6-9Storage ModuleIf the 7046T-NTR+ is to be used in a rack confi guration, you must turn the storage module 90 degrees
vii2-6 Checking the Drive Bay Setup ... 2-9Chapter 3 System Interface3-1 Overvie
6-10SUPERSERVER 7046T-NTR+ User's ManualAdding Drives to the Storage ModuleThe storage module includes three full sized drive bays and the front
Chapter 6: Advanced Chassis Setup6-11Figure 6-8. Adding Drives to the Mobile Rack6-5 Power SupplyThe SuperServer 7046T-NTR+ has a redundant 800 watt
6-12SUPERSERVER 7046T-NTR+ User's ManualInstalling a New Power SupplyReplace the failed module with another power supply module (must be the 1. e
Chapter 7: BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the AMI BIOS Setup Utility for the X8DTN+. The AMI ROM BIOS is stored in a Fla
7-2SUPERSERVER 7046T-NTR+ User's ManualStarting the Setup UtilityNormally, the only visible Power-On Self-Test (POST) routine is the memory test.
Chapter 7: BIOS7-3Supermicro X8DTN+BIOS Build Version• : This item displays the BIOS revision used in your sys-tem.BIOS Build Date• : This item disp
7-4SUPERSERVER 7046T-NTR+ User's Manual7-3 Advanced Setup Confi gurationsUse the arrow keys to select Boot Setup and hit <Enter> to access
Chapter 7: BIOS7-5Hit 'Del' Message DisplayThis feature displays "Press DEL to run Setup" during POST. The options are Enabled and
7-6SUPERSERVER 7046T-NTR+ User's ManualC1E SupportSelect Enabled to use the feature of Enhanced Halt State. C1E signifi cantly reduces the CPU&apo
Chapter 7: BIOS7-7tion and heat dissipation. Please refer to Intel’s web site for detailed information. The options are Disable (Disable GV3) and Ena
viiiX8DTN+ Quick Reference ... 5-125-9 Connector Defi nitions ...
7-8SUPERSERVER 7046T-NTR+ User's ManualQPI L0s and L1This enables the QPI power state to low power. L0s and L1 are automatically selected by the
Chapter 7: BIOS7-9Guardband Temperature (Available for Closed Loop only)This is the temperature which applies to the DIMM temperature threshold. Each
7-10SUPERSERVER 7046T-NTR+ User's Manualprocessor that is installed on an add-on card or a network card to handle some or all packet processing o
Chapter 7: BIOS7-11BIOS EHCI Hand-OffSelect Enabled to enable BIOS Enhanced Host Controller Interface support to provide a workaround solution for an
7-12SUPERSERVER 7046T-NTR+ User's ManualICH RAID Code Base (This feature is available when the option-RAID is selected)Select Intel to enable Int
Chapter 7: BIOS7-13PIO ModeThe IDE PIO (Programmable I/O) Mode programs timing cycles between the IDE drive and the programmable IDE controller. As th
7-14SUPERSERVER 7046T-NTR+ User's ManualSelect UDMA2 to allow the BIOS to use Ultra DMA mode 2. It has a data transfer rate of 33.3 MBs. Select U
Chapter 7: BIOS7-15PCI Latency TimerThis feature sets the latency Timer of each PCI device installed on a PCI bus. Select 64 to set the PCI latency to
7-16SUPERSERVER 7046T-NTR+ User's ManualSerial Port NumberThis feature allows the user decide which serial port to be used for Console Redi-recti
Chapter 7: BIOS7-17CPU Overheat AlarmThis option allows the user to select the CPU Overheat Alarm setting which de-termines when the CPU OH alarm will
Chapter 1 Introduction1-1 OverviewThe SuperServer 7046T-NTR+ is a high-end server comprised of two main sub-systems: the SC745TQ-R800B server chassis
7-18SUPERSERVER 7046T-NTR+ User's Manualseeing a temperature reading (i.e., 25oC). The CPU Temperature feature will display the CPU temperature s
Chapter 7: BIOS7-19Voltages ReadingsThe following voltage readings will be displayed.CPU1 Vcore, CPU2 Vcore, +5Vin, +12V, -12V 3.3Vcc (V), and Battery
7-20SUPERSERVER 7046T-NTR+ User's ManualTPM Enable/Disable StatusThis item displays the status of TPM Support to indicate if TPM is currently ena
Chapter 7: BIOS7-21Clear BMC System Event LogSelect OK and press the <Enter> key to clear the BMC system log. Select Cancel to keep the BMC Syst
7-22SUPERSERVER 7046T-NTR+ User's ManualParameter SelectorUse this feature to select the parameter of your Mac Address confi guration.Mac Address
Chapter 7: BIOS7-23PEF Alert Startup Delay (Available if the item-PEF Support is enabled)This sets the pre-determined time to delay PEF alerts after s
7-24SUPERSERVER 7046T-NTR+ User's Manual7-4 Security SettingsThe AMIBIOS Setup Utility provides a Supervisor and a User password. If you use both
Chapter 7: BIOS7-257-5 Boot Confi gurationUse this feature to confi gure boot settings. XBoot Device PriorityThis feature allows the user to specify the
7-26SUPERSERVER 7046T-NTR+ User's Manual7-6 Exit OptionsSelect the Exit tab from the AMI BIOS Setup Utility screen to enter the Exit BIOS Setup s
A-1Appendix A: BIOS Error Beep CodesAppendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the
Komentáře k této Příručce