®SUPERSERVER 6036ST-6LR SUPERUSER’S MANUAL1.0a
1-2SUPERSERVER 6036ST-6LR User's Manual1-2 Serverboard FeaturesThe SuperServer 6036ST-6LR is built around two X8DTS-F serverboards for a dual-nod
1-3Chapter 1: IntroductionRear Chassis PortsThe rear of the chassis includes one SAS port, two 1 GB Ethernet ports and a KVM connector (includes USB,
1-4SUPERSERVER 6036ST-6LR User's ManualFigure 1-1. Intel I5520 + OH-36D/ICH10 Chipset: System Block DiagramNote: This is a general block diagram
1-5Chapter 1: Introduction1-4 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131 U.S.A.Tel: +1 (40
1-6SUPERSERVER 6036ST-6LR User's Manual1-5 SBB: Storage Bridge BayThe 6036ST-6LR Super SBB was designed to function as a fully redundant, fault-
Chapter 2: Server Installation2-1Chapter 2 Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get your SuperServer 6036ST
2-2SUPERSERVER 6036ST-6LR User's ManualThis product is for installation only in a Restricted Access Location (dedicated • equipment rooms, servic
Chapter 2: Server Installation2-3Rack Mounting ConsiderationsAmbient Operating TemperatureIf installed in a closed or multi-unit rack assembly, the am
2-4SUPERSERVER 6036ST-6LR User's Manual2-4 Installing the System into a RackThis section provides information on installing the SC937 chassis in
Chapter 2: Server Installation2-5Figure 2-2. Outer Rack RailsFigure 2-3. Outer Rack Rail InstallInstalling the Outer Rack RailsOuter rails attach to
Manual Revision 1.0a Release Date: February 9, 2011Unless you request and receive written permission from Super Micro Computer, Inc., you may no
2-6SUPERSERVER 6036ST-6LR User's ManualFigure 2-3. Installing the Chassis into the RackInstalling the Chassis into a RackInstalling into a RackC
Chapter 2: Server Installation2-72-5 Checking the Serverboard SetupAfter you install the 6036ST-6LR in the rack, you will need to open the unit to ma
2-8SUPERSERVER 6036ST-6LR User's ManualFigure 2-4. Accessing the Inside of the System111211
Chapter 2: Server Installation2-92-6 Checking the Drive Bay SetupNext, you should check to make sure the peripheral drives and the SAS/SATA drives ha
2-10SUPERSERVER 6036ST-6LR User's ManualNotes
Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are several LEDs on two control panels as well as others on the drive carrie
SUPERSERVER 6036ST-6LR User's Manual3-212Overheat/Fan Fail:When this LED fl ashes, it indicates a fan failure. When on continuously it indicates a
Chapter 3: System Interface3-3PowerIndicates power is being supplied to the system's power supply units. This LED should normally be illuminated
SUPERSERVER 6036ST-6LR User's Manual3-4Notes
Chapter 4: System Safety4-1Chapter 4 System Safety4-1 Electrical Safety Precautions!Basic electrical safety precautions should be followed to protect
iiiPrefacePrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the insta
SUPERSERVER 6036ST-6LR User's Manual4-24-2 General Safety PrecautionsFollow these rules to ensure general safety:Keep the area around the 6036ST
Chapter 4: System Safety4-34-3 ESD PrecautionsElectrostatic Discharge (ESD) is generated by two objects with different electrical charges coming into
SUPERSERVER 6036ST-6LR User's Manual4-44-4 Operating PrecautionsCare must be taken to assure that the chassis cover is in place when the 6036ST-6
Chapter 5: Advanced Serverboard Setup5-1Chapter 5 Advanced Serverboard SetupThis chapter provides detailed information on the X8DTS-F serverboard. All
5-2SUPERSERVER 6036ST-6LR User's ManualUnpackingThe serverboard is shipped in antistatic packaging to avoid electrical static dis-charge. When un
Chapter 5: Advanced Serverboard Setup5-3!Press the socket clip to release 1. the load plate, which covers the CPU socket, from its locked posi-tion.Ge
5-4SUPERSERVER 6036ST-6LR User's ManualAfter removing the plastic cap, use 1. your thumb and the index fi nger to hold the CPU at the north and so
Chapter 5: Advanced Serverboard Setup5-5Place the heatsink on top of the 1. CPU so that the four mounting holes are aligned with those on the retentio
5-6SUPERSERVER 6036ST-6LR User's ManualMemory SupportThe X8DTS-F supports up to 48 GB of ECC registered DDR3-1333/1066/800 or up to 24 GB of ECC/
Chapter 5: Advanced Serverboard Setup5-7DIMM Module Population Confi gurationFollow the tables below when installing memory.Memory Population for Optim
SUPERSERVER 6036ST-6LR User's ManualivChapter 5: Advanced Serverboard SetupChapter 5 provides detailed information on the X8DTS-F serverboard, i
5-8SUPERSERVER 6036ST-6LR User's Manual5-5 Installing PCI Add-On CardsEach node in the 6036ST-6LR can accommodate up to three PCI add-on cards.
Chapter 5: Advanced Serverboard Setup5-9Figure 5-4. Installing Add-on Cards
5-10SUPERSERVER 6036ST-6LR User's ManualFigure 5-5. X8DTS-F Layout(not drawn to scale)5-6 Serverboard DetailsNote: jumpers not indicated are for
Chapter 5: Advanced Serverboard Setup5-11X8DTS-F Quick ReferenceJumper Description Default SettingJBT1 CMOS Clear (See Section 5-8)JPG1 VGA Enable/Dis
5-12SUPERSERVER 6036ST-6LR User's Manual5-7 Connector Defi nitions KVM Port (USB/VGA/Serial Port)The KVM port, located next to the External SAS po
Chapter 5: Advanced Serverboard Setup5-13SATA PortPin Defi nitions Pin# Defi nition 1 Ground2 TX_P3 TX_N4 Ground5 RX_N6 RX_P7 GroundOnboard SATA
5-14SUPERSERVER 6036ST-6LR User's Manual5-8 Jumper SettingsExplanation of JumpersTo modify the operation of the serverboard, jumpers can be used
Chapter 5: Advanced Serverboard Setup5-15VGA Enable/DisableJPG1 allows you to enable or disable the VGA port. The default position is on pins 1 and 2
5-16SUPERSERVER 6036ST-6LR User's Manual5-9 Onboard IndicatorsLAN LEDsThe Ethernet ports (located on the I/O backplane) have two LEDs. On each po
Chapter 5: Advanced Serverboard Setup5-17BMC Heartbeat LED A BMC Heartbeat LED is located at LED7. When this LED is on, the BMC is functioning normall
NotesPrefacev
5-18SUPERSERVER 6036ST-6LR User's ManualSuperDoctor IIIThe SuperDoctor III program is a web-based management tool that supports remote management
Chapter 5: Advanced Serverboard Setup5-19Note: SuperDoctor III Software Revision 1.0 can be downloaded from our Web Site at: ftp://ftp.supermicro.com/
5-20SUPERSERVER 6036ST-6LR User's ManualNotes
Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform mainte-na
6-2SUPERSERVER 6036ST-6LR User's ManualFigure 6-1. Front and Rear Chassis Views6-2 Control PanelThe control panels are connected to the serverbo
Chapter 6: Advanced Chassis Setup6-36-3 System FansSystem cooling is provided by three sets of counter-rotating fans on each serverboard as well as an
6-4SUPERSERVER 6036ST-6LR User's ManualFigure 6-2. Replacing a Serverboard FanFigure 6-3. Exploded View of Fan Assembly23
Chapter 6: Advanced Chassis Setup6-56-4 Drive Bay Installation/RemovalAccessing the Drive BaysSAS/SATA Drives: You do not need to access the inside o
6-6SUPERSERVER 6036ST-6LR User's Manual!Important: Regardless of how many hard drives are installed, all drive car-riers must remain in the drive
Chapter 6: Advanced Chassis Setup6-7Figure 6-5. Removing the Dummy Drive from the CarrierDrive CarrierDummy Drive111112Figure 6-6. Installing a Drive
viTable of ContentsChapter 1 Introduction1-1 Overview ...
6-8SUPERSERVER 6036ST-6LR User's ManualFigure 6-7. Midplane Connections6-5 MidplaneThe midplane supplies power and logic to the hard drives as w
Chapter 6: Advanced Chassis Setup6-96-6 Power SupplyThe SuperServer 6036ST-6LR has a 1200 watt redundant power supply consisting of two separate power
6-10SUPERSERVER 6036ST-6LR User's ManualNotes
Chapter 7: BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the AMI BIOS Setup Utility for the X8DTS-F. The AMI ROM BIOS is stored in a Fl
7-2SUPERSERVER 6036ST-6LR User's ManualStarting the Setup UtilityNormally, the only visible Power-On Self-Test (POST) routine is the memory test.
Chapter 7: BIOS7-3Supermicro X8DTS-F-FBIOS Build Version• : This item displays the BIOS revision used in your sys-tem.BIOS Build Date• : This item d
7-4SUPERSERVER 6036ST-6LR User's Manual7-3 Advanced Setup Confi gurationsUse the arrow keys to select Boot Setup and press <Enter> to acces
Chapter 7: BIOS7-5Hit 'Del' Message DisplayThis feature displays "Press DEL to run Setup" during POST. The options are Enabled and
7-6SUPERSERVER 6036ST-6LR User's ManualC1E SupportSelect Enabled to enable Enhanced Halt State support. C1E signifi cantly reduces the CPU's
Chapter 7: BIOS7-7tion and heat dissipation. Please refer to Intel’s web site for detailed information. The options are Disable (Disable GV3) and Ena
vii2-5 Checking the Serverboard Setup ... 2-72-6 Checking the Drive Bay Setup ...
7-8SUPERSERVER 6036ST-6LR User's ManualQPI L0s and L1This feature allows the user to set the QPI power state to a low setting. L0s and L1 are aut
Chapter 7: BIOS7-9Inlet TemperatureThis is the temperature detected at the chassis inlet. Each step is in 0.5oC increment. The default is [070]. Pres
7-10SUPERSERVER 6036ST-6LR User's Manualor all packet processing of this add-on card.) When this feature is set to Enabled, it will enhance overa
Chapter 7: BIOS7-11USB 2.0 ControllerSelect Enabled to activate USB 2.0 Controller. The options are Enabled and Dis-abled. (Note: If the item - USB Fu
7-12SUPERSERVER 6036ST-6LR User's ManualPrimary IDE MasterThese settings allow the user to set the parameters of the IDE slots as specifi ed. Pres
Chapter 7: BIOS7-13DMA ModeSelect Auto to allow the BIOS to automatically detect IDE DMA mode when the IDE disk drive support cannot be determined. Se
7-14SUPERSERVER 6036ST-6LR User's Manual32Bit Data TransferSelect Enable to enable the function of 32-bit IDE data transfer. The options are Enab
Chapter 7: BIOS7-15XRemote Access Confi guration Remote Access This allows the user to enable or disable Remote Access support. The options are Disable
7-16SUPERSERVER 6036ST-6LR User's ManualXHardware Health Confi gurationThis feature allows the user to monitor system health and review the status
Chapter 7: BIOS7-17Supermicro has leveraged this feature by assigning a temperature status to certain thermal conditions in the processor (Low, Medium
viii5-7 Connector Defi nitions ... 5-125-8 Jumper Settings ...
7-18SUPERSERVER 6036ST-6LR User's ManualSelect "Balanced/BL" for the onboard fans to run at a speed that will balance the needs between
Chapter 7: BIOS7-19pendency on other timestamp calculation devices, such as an x86 RDTSC Instruc-tion embedded in the CPU. The High Performance Event
7-20SUPERSERVER 6036ST-6LR User's ManualIPMI Firmware RevisionThis feature displays the IPMI Firmware Revision Number for your system.XView BMC S
Chapter 7: BIOS7-21Clear BMC System Event LogSelect OK and press the <Enter> key to clear the BMC system log. Select Cancel to keep the BMC Syst
7-22SUPERSERVER 6036ST-6LR User's ManualIP Address SourceThis feature allows the user to select the source of the IP address for the system. If S
Chapter 7: BIOS7-23XGateway Address Confi gurationEnter the gateway address for this machine. This should be in decimal and in dotted quad form (i.e.,
7-24SUPERSERVER 6036ST-6LR User's Manual7-4 Security SettingsThe AMIBIOS Setup Utility provides a Supervisor and a User password. If you use both
Chapter 7: BIOS7-257-5 Boot Confi gurationUse this feature to confi gure boot settings. XBoot Device PriorityThis feature allows the user to specify the
7-26SUPERSERVER 6036ST-6LR User's Manual7-6 Exit OptionsSelect the Exit tab from the AMI BIOS Utility to enter the Exit BIOS Setup screen.Save Ch
A-1Appendix A: BIOS POST Error CodesAppendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the
Chapter 1 Introduction1-1 OverviewThe SuperServer 6036ST-6LR is a high-end Super Storage Bridge Bay (SBB) sys-tem comprised of two main subsystems: th
A-2SUPERSERVER 6036ST-6LR User's ManualNotes
B-1Appendix C: System Specifi cationsAppendix B System Specifi cationsProcessors (each node) Single or dual Intel® Xeon 5500/5600 Series processors
B-2SUPERSERVER 6036ST-6LR User's ManualWeight Gross (Bare Bone): 75 lbs. (34 kg.)System Cooling Three sets of 4-cm counter-rotating
B-3Appendix C: System Specifi cationsNotes
B-4SUPERSERVER 6036ST-6LR User's Manual(continued from front)The products sold by Supermicro are not intended for and will not be used in life su
Komentáře k této Příručce