Supermicro 1012C-MRF Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Barebone serveru Supermicro 1012C-MRF. Supermicro 1012C-MRF Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 92
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků

Shrnutí obsahu

Strany 1

SUPER®A+Server 1012C-MRFUSER’S MANUALRevision 1.0a

Strany 2 - Manual Revision Revision 1.0a

1-2A+ Server 1012C-MRF User's Manual1-2 Serverboard FeaturesAt the heart of the A+ Server 1012C-MRF is the H8SCM-F single processor serverboard,

Strany 3 - Manual Organization

Chapter 1: Introduction1-3Graphics ControllerThe H8SCM-F features an integrated Matrox G200eW graphics chip, which includes 16 MB of DDR2 memory.Other

Strany 4

1-4A+ Server 1012C-MRF User's Manual1-3 Server Chassis FeaturesThe A+ Server 1012C-MRF is built on the SC512F-350B 1U rackmount server chassis.

Strany 5

Chapter 1: Introduction1-51-4 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131 U.S.A.Tel: +1 (408

Strany 6 - Table of Contents

1-6A+ Server 1012C-MRF User's ManualNotes

Strany 7 - Chapter 4 System Safety

Chapter 2: Server Installation2-1Chapter 2 Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get your SuperServer 1012C-

Strany 8

2-2A+ Server 1012C-MRF User's Manual!!Warnings and Precautions!installation only in a Restricted Access Location (dedicated equipment rooms, serv

Strany 9 - Introduction

Chapter 2: Server Installation2-3Rack Mounting ConsiderationsAmbient Operating TemperatureIf installed in a closed or multi-unit rack assembly, the am

Strany 10 - 1-2 Serverboard Features

2-4A+ Server 1012C-MRF User's Manual2-4 Installing the System into a RackThis section provides information on installing the SuperServer 1012C-M

Strany 11 - Other Features

Chapter 2: Server Installation2-5Installing with Rackmount KitThis is a guideline for installing the unit into a rack with the optional rack kit (MCP-

Strany 12 - 1-3 Server Chassis Features

The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccu

Strany 13 - 1-4 Contacting Supermicro

2-6A+ Server 1012C-MRF User's ManualInstalling the Rack RailsDetermine where you want to place the 1012C-MRF in the rack (see Rack 1. and Server

Strany 14

Chapter 2: Server Installation2-7Figure 2-3. Installing the Server into a Rack(w/ Optional Rackmount Kit)Finish by inserting and tightening the thumbs

Strany 15 - Server Installation

2-8A+ Server 1012C-MRF User's ManualFigure 2-4. Installing the Server into a Telco Rack

Strany 16 - Warnings and Precautions!

Chapter 2: Server Installation2-92-5 Checking the Serverboard SetupAfter you install the server in the rack, you will need to open the unit to make s

Strany 17 - Rack Mounting Considerations

2-10A+ Server 1012C-MRF User's Manual2-6 Checking the Drive Bay SetupChecking the DrivesFor servicing the SATA and DVD-ROM drives, you will need

Strany 18 - Basic Installation Procedure

Chapter 2: Server Installation2-11Figure 2-5. Accessing the Inside of the ServerRemove these screwsRemove this screwRemove these screws

Strany 19 - Installing with Rackmount Kit

2-12A+ Server 1012C-MRF User's ManualNotes

Strany 20

Chapter 3: System Interface3-1PowerThe main power button is used to apply or remove power from the power supply to the server system. Turning off syst

Strany 21

3-2A+ Server 1012C-MRF User's ManualNIC2Indicates network activity on LAN2 when fl ashing .3-3 Control Panel LEDsThe control panel located on the

Strany 22

Chapter 4: System Safety4-1Chapter 4 System Safety4-1 Electrical Safety Precautions!Basic electrical safety precautions should be followed to protect

Strany 23

PrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the installation an

Strany 24

4-2A+ Server 1012C-MRF User's ManualThe power supply power cords must include a grounding plug and must be • plugged into grounded electrical out

Strany 25 - Remove this screw

Chapter 4: System Safety4-3While working on the system, do not wear loose clothing such as neckties and • unbuttoned shirt sleeves, which can come int

Strany 26

4-4A+ Server 1012C-MRF User's ManualFor grounding purposes, make sure your computer chassis provides excellent • conductivity between the power s

Strany 27 - System Interface

Chapter 4: System Safety5-1Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to install the H8SCM-F serverboard into the SC51

Strany 28 - 3-3 Control Panel LEDs

5-2A+ Server 1012C-MRF User's ManualFigure 5-1. I/O PortsUnpackingThe serverboard is shipped in antistatic packaging to avoid electrostatic disch

Strany 29 - System Safety

Chapter 4: System Safety5-35-3 Processor and Heatsink InstallationNotes: Always connect the power cord last and always remove it before adding, re-•

Strany 30

5-4A+ Server 1012C-MRF User's ManualAlign pin 1 of the CPU with pin 1 of the 3. socket. Once aligned, carefully place the CPU into the socket. Do

Strany 31 - 4-3 ESD Precautions

Chapter 4: System Safety5-5Installing a Passive HeatsinkTo install the SNK-0022+ Passive Heatsink, use the following procedure:Installing a SNK-0022+

Strany 32 - BATTERY HOLDER

5-6A+ Server 1012C-MRF User's Manual5-4 Installing Memory!CAUTION! Exercise extreme care when installing or removing DIMM modules to prevent any

Strany 33 - Advanced Serverboard Setup

Chapter 4: System Safety5-7Figure 5-4. DIMM InstallationTo Install: Insert module vertically and press down until it snaps into place. Pay attention t

Strany 34 - Front Control Panel

A+ Server 1012C-MRF User's ManualivChapter 6: Advanced Chassis SetupRefer to Chapter 6 for detailed information on the SC512F-350B 1U rackmount s

Strany 35

5-8A+ Server 1012C-MRF User's ManualNote 2: Due to memory allocation to system devices, the amount of memory that remains available for operation

Strany 36

Chapter 4: System Safety5-95-5 Adding PCI CardsPCI Express SlotThe 1012C-MRF includes a preinstalled riser card designed specifi cally for use in the

Strany 37 - Removing the Heatsink

5-10A+ Server 1012C-MRF User's ManualFigure 5-5. H8SCM-F Serverboard Layout5-6 Serverboard DetailsJD1FAN4 FAN3FAN2FAN5SATA0 SATA1SATA2 SATA3SATA4

Strany 38 - 5-4 Installing Memory

Chapter 4: System Safety5-11H8SCM(-F) Quick ReferenceJumper Description Default SettingJBT1 CMOS Clear (See Section 2-7)JCF1 Compact Flash Master/Slav

Strany 39

5-12A+ Server 1012C-MRF User's Manual5-7 Connector Defi nitions Power Connectors A 24-pin main power supply connector(JPW1) and three 8-pin CPU P

Strany 40 - (4 GB Total System

Chapter 4: System Safety5-13NIC2 (LAN2) LEDThe LED connections for LAN2 are on pins 9 and 10 of JF1. Attach LAN LED cables to display network activity

Strany 41 - 5-5 Adding PCI Cards

5-14A+ Server 1012C-MRF User's ManualUniversal Serial Bus PortsTwo Universal Serial Bus ports (USB 2.0) are located beside the Keyboard and Mouse

Strany 42 - 5-6 Serverboard Details

Chapter 4: System Safety5-15Wake-On-LANThe Wake-On-LAN header is designated JWOL1. See the table on the right for pin defi nitions. You must have a LAN

Strany 43 - H8SCM(-F) Quick Reference

5-16A+ Server 1012C-MRF User's ManualATX PS/2 Keyboard and PS/2 Mouse PortsThe ATX PS/2 keyboard and PS/2 mouse are located next to the Back Pane

Strany 44 - 5-7 Connector Defi nitions

Chapter 4: System Safety5-175-8 Jumper SettingsExplanation of JumpersTo modify the operation of the motherboard, jumpers can be used to choose between

Strany 45

vPrefaceNotes

Strany 46

5-18A+ Server 1012C-MRF User's ManualVGA Enable/DisableJPG1 allows you to enable or disable the VGA port. The default position is on pins 1 and 2

Strany 47

Chapter 4: System Safety5-19I2C to PCI-Express SlotJI2C1/JI2C2 allows you to enable the I2C bus to communicate with the PCI-Express slot. For the jump

Strany 48

5-20A+ Server 1012C-MRF User's Manual5-9 Onboard IndicatorsLAN1/LAN2 LEDsThe Ethernet ports (located beside the VGA port) have two LEDs. On each

Strany 49 - 5-8 Jumper Settings

Chapter 4: System Safety5-215-10 IDE and SATA Drive ConnectionsUse the following information to connect the IDE hard disk drive cables.A red mark on

Strany 50

5-22A+ Server 1012C-MRF User's Manual5-11 Enabling SATA RAIDNow that the hardware is set up, you must install the operating system and the SATA

Strany 51

Chapter 4: System Safety5-23Figure 5-6. BIOS Setup ScreenNote: You need to have an external USB fl oppy when building the driver diskette. Window'

Strany 52 - 5-9 Onboard Indicators

5-24A+ Server 1012C-MRF User's ManualAfter exiting the BIOS Setup Utility, the system will reboot. When prompted 4. during the startup, press the

Strany 53 - (SATA0-SATA5)

Chapter 4: System Safety5-25Figure 5-8. Driver/Tool Installation Display Screen5-12 Installing DriversThe CD that came bundled with the system contain

Strany 54 - 5-11 Enabling SATA RAID

5-26A+ Server 1012C-MRF User's ManualSupero Doctor IIIThe Supero Doctor III program is a Web base management tool that supports remote management

Strany 55

Chapter 4: System Safety5-27Figure 5-10. Supero Doctor III Interface Display Screen (Remote Control)Note: Super Doctor III Software Revision 1.0 can

Strany 56

viA+ Server 1012C-MRF User's ManualTable of ContentsChapter 1 Introduction1-1 Overview ...

Strany 57 - 5-12 Installing Drivers

5-28A+ Server 1012C-MRF User's ManualNotes

Strany 58 - Supero Doctor III

Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform maintenan

Strany 59

6-2A+ Server 1012C-MRF User's ManualUnpackingThe serverboard is shipped in antistatic packaging to avoid static damage. When unpacking the board,

Strany 60

Chapter 6: Advanced Chassis Setup6-3System Fan FailureIf a fan fails, the remaining fans will ramp up to full speed and the overheat/fan fail LED on t

Strany 61 - Advanced Chassis Setup

6-4A+ Server 1012C-MRF User's ManualFigure 6-2. System Cooling Fans6-4 Drive Bay Installation/RemovalAccessing the Drive BaysDVD-ROM/Serial ATA

Strany 62 - 6-3 System Fans

Chapter 6: Advanced Chassis Setup6-5Replace the top cover when fi nished. See Figure 6-3.6. Note: the 1012C-MRF can accommodate two internal SATA hard

Strany 63 - System Fan Failure

6-6A+ Server 1012C-MRF User's ManualFigure 6-3. Removing the DVD-ROM DriveCarefully lift the server out of the rack.3. Open the cover by removing

Strany 64 - Accessing the Drive Bays

Chapter 6: Advanced Chassis Setup6-7Power Supply FailureIf the power supply unit fails, the system will shut down and you will need to replace the pow

Strany 65

6-8A+ Server 1012C-MRF User's ManualNotes

Strany 66 - 6-5 Power Supply

Chapter 7: BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the AMI BIOS Setup Utility for the H8SCM-F. The AMI ROM BIOS is stored in a Fl

Strany 67 - Power Supply Failure

viiTable of Contents3-1 Overview ... 3-13-2 Con

Strany 68

7-2A+ Server 1012C-MRF User's ManualStarting the Setup UtilityNormally, the only visible Power-On Self-Test (POST) routine is the memory test. A

Strany 69 - Chapter 7

Chapter 7: BIOS7-3Quiet BootIf Disabled, normal POST messages will be displayed on boot-up. If Enabled, this display the OEM logo instead of POST mess

Strany 70 - 7-3 Advanced Settings Menu

7-4A+ Server 1012C-MRF User's ManualEUP SupportThis setting allows you to enable or disable supplied standby power in S5. Set to Enabled to for E

Strany 71

Chapter 7: BIOS7-5Clock Speed SpectrumThis option enables or disables spread spectrum modulation. Advanced Chipset Control NorthBridge Confi guratio

Strany 72

7-6A+ Server 1012C-MRF User's Manual ECC Confi gurationECC ModeThis submenu affects the DRAM scrub rate based on its setting. Options include Dis

Strany 73 -  NorthBridge Confi guration

Chapter 7: BIOS7-7 IDE Confi gurationOnboard PCI IDE ControllerThis setting allows you to Enable or Disable the PCI IDE controller.On Chip SATA Channe

Strany 74 -  DRAM Timing Confi guration

7-8A+ Server 1012C-MRF User's ManualThe options are Auto, 0, 1, 2, 3, and 4. Select Auto to allow BIOS to auto detect the PIO mode. Use this valu

Strany 75 -  IDE Confi guration

Chapter 7: BIOS7-9 PCI/PnP Confi gurationClear NVRAMSelect Yes to clear NVRAM during boot-up. The options are Yes and No.Plug & Play O/SSelect Yes

Strany 76

7-10A+ Server 1012C-MRF User's ManualPrimary Video ControllerThis option specifi es the primary video controller for Onboard VGA or Other. Super

Strany 77 -  PCI/PnP Confi guration

Chapter 7: BIOS7-11Flow ControlSelects the fl ow control to be used for console redirection. Options are None, Hardware and Software.Redirection After

Strany 78 -  Remote Access Confi guration

viiiA+ Server 1012C-MRF User's ManualUsing the Adaptec RAID Utility ... 5-24Ins

Strany 79

7-12A+ Server 1012C-MRF User's Manual ACPI Confi gurationPS2 KB/MS WakeupThis setting allows you to Enable or Disable PS2 keyboard and mouse wake

Strany 80 -  View BMC System Event Log

Chapter 7: BIOS7-13 Set LAN Confi gurationUse the "+" and "-" keys to choose the desired channel number. This displays Channel Num

Strany 81 -  Set LAN Confi guration

7-14A+ Server 1012C-MRF User's ManualBMC Watch Dog Timer ActionThis setting is used to set the Watch Dog function, which allows the BMC to reset

Strany 82 - 4-3 Security Menu

Chapter 7: BIOS7-154-4 Boot MenuThe Boot Menu is accessible only when the "Load Onboard LAN Option ROM" setting (in the PCI/PnP Confi guratio

Strany 83 - 4-4 Boot Menu

7-16A+ Server 1012C-MRF User's Manual4-5 Exit MenuSelect the Exit tab from AMI BIOS Setup Utility screen to enter the Exit BIOS Setup screen.Save

Strany 84 - 4-5 Exit Menu

A-1Appendix A: BIOS Error Beep CodesAppendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the

Strany 85 - BIOS Error Beep Codes

A-2A+ Server 1012C-MRF/GIBXF/GIQXF User's ManualNotes

Strany 86

Appendix B: Installing WindowsB-1Appendix B Installing Windows After all hardware components have been installed, you must fi rst confi gure RAID Settin

Strany 87 - Installing Windows

B-2A+ Server 1012C-MRF User's ManualFrom the Windows XP/Windows 2003 Setup screen, press the <Enter> key. 9. The XP/2003 Setup will automat

Strany 88

C-1Appendix C: System Specifi cationsAppendix C System Specifi cationsProcessorsDual AMD Opteron 4100 series (AMD Socket C32 type) processorsNote: pleas

Strany 89 - System Specifi cations

Chapter 1: Introduction1-1Chapter 1 Introduction1-1 OverviewThe A+ Server 1012C-MRF is a 1U server comprised of the SC512F-350B chassis and one H8SCM-

Strany 90

C-2A+ Server 1012C-MRF User's ManualChassisSC512F-350B (1U rackmount)Dimensions: (WxHxD) 17.2 x 1.7 x 14.5 in. (437 x 43 x 368 mm)WeightGross (Ba

Strany 91

C-3Appendix C: System Specifi cationsNotes

Strany 92

C-4A+ Server 1012C-MRF User's Manual(continued from front)The products sold by Supermicro are not intended for and will not be used in life suppo

Komentáře k této Příručce

Žádné komentáře