SUPERUSER’S MANUALRevision 1.0®SuperServer6026TT-H6RF6026TT-H6IBXRF6026TT-H6IBQRF
NotesSUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's Manual
7-28SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's ManualBoot Sector Recovery from a Serial Port ("Serial Flash")This process, also
Chapter 7: BIOS7-294. Power on your system and click the <Connect> button in the Hyper Terminal. The terminal screen will display the following
7-30SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's Manual6. Once you've completed the instructions given, a screen will display to indi
A-1Appendix A: BIOS Error Beep CodesAppendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the
A-2SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's ManualNotes
Appendix B: Installing WindowsB-1Appendix B Installing Windows After all hardware components have been installed, you must fi rst confi gure Intel Sout
B-2SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's ManualB-2 Installing Windows for a Non-RAID SystemInsert Microsoft's Windows XP/2003
C-1Appendix C: System Specifi cationsAppendix C System Specifi cationsNote: unless noted specifi cations apply to a complete system (four server-boards).
C-2SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's ManualServerboard6026TT-H6RF+: X8DTT-HEF+6026TT-H6IBXRF: X8DTT-HIBXF+6026TT-H6IBQRF: X8DTT-
C-3Appendix C: System Specifi cationsRegulatory ComplianceElectromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-3, CISPR 22 Class A
Chapter 1 Introduction1-1 OverviewThe SuperServer SYS-6026TT-H6RF/H6IBXRF/H6IBQRF is a "2U Twin2" server comprised of the SC827HQ-R1400B 2U
C-4SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's Manual(continued from front)The products sold by Supermicro are not intended for and will n
1-2SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's Manual1-2 Serverboard FeaturesAt the heart of the SuperServer 6026TT are four X8DTT-HEF+/HI
Chapter 1: Introduction1-3Ethernet PortsAn Intel® network controller is integrated into each of the serverboards to support two Gigabit LAN ports (100
1-4SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's ManualFigure 1-1. Intel 5520 Chipset:System Block DiagramNote1: This is a general block dia
Chapter 1: Introduction1-51-3 Server Chassis FeaturesThe following is a general outline of the main features of the SC827HQ-R1400B 2U chassis. Detail
1-6SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's Manual1-4 2U Twin2: System NotesAs a 2U Twin2 confi guration, the SYS-6026TT-H6RF/H6IBXRF/H6
Chapter 1: Introduction1-71-5 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131 U.S.A.Tel: +1 (40
1-8SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's ManualNotes
Chapter 2: Server Installation2-1Chapter 2 Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get the SYS-6026TT-H6RF/H6I
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccu
2-2SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's ManualChoosing a Setup LocationLeave enough clearance in front of the rack to enable you to
Chapter 2: Server Installation2-3Allow the hot plug SATA drives and power supply modules to cool before touch-• ing them.Always keep the rack's f
2-4SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's Manual!Warning: Except for short periods of time, do NOT operate the server without the cov
Chapter 2: Server Installation2-52-4 Rack Mounting InstructionsThis section provides information on installing the SC827 chassis into a rack unit wit
2-6SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's ManualFigure 2-3. Installing the Inner Rail ExtensionsInstalling the Inner Rail ExtensionsT
Chapter 2: Server Installation2-7Outer Rack RailsOuter rails attach to the rack and hold the chassis in place. The outer rails for the SC827 chassis e
2-8SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's ManualFigure 2-5: Installing Into the RackInstalling the Chassis into a RackExtend the oute
Chapter 2: Server Installation2-92-5 Checking the Serverboard SetupAfter you install the system in the rack, you will need to access the inside of th
2-10SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's Manual2-6 Preparing to Power OnNext, you should check to make sure the SATA drives and SA
Chapter 2: Server Installation2-11Figure 2-6. Removing a Node from the System1111121211
PrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the installation an
2-12SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's ManualNotes
Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are LEDs on the control panels and on the SATA drive carriers to keep you co
3-2SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's Manual3-3 Control Panel LEDsIn addition to the LEDs built into the power and UID buttons,
Chapter 4: System Safety4-1Chapter 4 System Safety4-1 Electrical Safety Precautions!Basic electrical safety precautions should be followed to protect
SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's Manual4-2This product may be connected to an IT power system. In all cases, make sure • that t
Chapter 4: System Safety4-3Remove any jewelry or metal objects from your body, which are excellent metal • conductors that can create short circuits a
SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's Manual4-44-4 Operating Precautions!Care must be taken to assure that the chassis cover is in p
Chapter 5: Advanced Serverboard Setup5-1Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to install the X8DTT-HEF+/HIBXF+/HI
5-2SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's ManualUnpackingThe serverboard is shipped in antistatic packaging to avoid electrostatic di
Chapter 5: Advanced Serverboard Setup5-3Warning: To avoid damaging the motherboard and its components, do not apply any force greater than 8 lbs. per
SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's ManualivChapter 3: System InterfaceRefer to this chapter for details on the system interface,
5-4SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's Manual!Starting with CPU1, press the 1. socket clip to release the load plate, which covers
Chapter 5: Advanced Serverboard Setup5-5After removing the plastic cap, use 1. your thumb and the index fi nger to hold the CPU at the north and south
5-6SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's ManualRemove power from the system 1. and unplug the AC power cord from the power supply.Do
Chapter 5: Advanced Serverboard Setup5-7Remove power from the system 1. and unplug the AC power cord from the power supply.Disconnect the heatsink fan
5-8SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's Manual5-5 Installing MemoryMemory SupportEach X8DTT-HEF+/HIBXF+/HIBQF+ has twelve 240-pin D
Chapter 5: Advanced Serverboard Setup5-9To Install: Insert module vertically and press down until it snaps into place. Pay attention to the alignment
5-10SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's Manual1.5V RDIMM Population with 5600 Processors InstalledDIMM Slots per ChannelDIMMs Popu
Chapter 5: Advanced Serverboard Setup5-115-6 Adding PCI CardsPCI Express SlotThe SYS-6026TT-H6RF/H6IBXRF/H6IBQRF includes four preinstalled riser car
5-12SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's ManualFigure 5-3. X8DTT-HEF+/HIBXF+/HIBQF+ Series Motherboard Layout5-7 Serverboard Detail
Chapter 5: Advanced Serverboard Setup5-13X8DTT-HEF+/HIBXF+/HIBQF+ Quick ReferenceJumper Description Default SettingJBT1 CMOS Clear (See Section 5-8)JP
vPrefaceNotes
5-14SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's Manual5-8 Connector Defi nitionsFront Panel Accessible Add-on Card Header (JF2)The JF2 add-
Chapter 5: Advanced Serverboard Setup5-15Fan HeaderPin Defi nitions Pin# Defi nition1 Ground2 +12V 3 Tachometer4 PWR ModulationUniversal Serial Bus
5-16SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's ManualEthernet PortsTwo Ethernet ports are located next to USB0/1 on the IO Backplane. In
Chapter 5: Advanced Serverboard Setup5-17Unit Identifi er SwitchesTwo Unit Identifi er (UID) switches and LED indicators are located on the motherboard.
5-18SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's Manual5-9 Jumper SettingsTo modify the operation of the serverboard, jumpers can be used t
Chapter 5: Advanced Serverboard Setup5-19LAN1/LAN2 Enable/Disable Change the setting of jumper JPL1/JPL2 to enable or disable the LAN1 and LAN2 ports
5-20SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's ManualOnboard Power LED An Onboard Power LED is located at LE1 on the motherboard. When th
Chapter 5: Advanced Serverboard Setup5-215-11 SATA and SAS PortsSATA ConnectionsA Front Panel Add-On Card header is located at JF2 on the motherboard
5-22SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's ManualDriver/Tool Installation Display ScreenNote: Click the icons showing a hand writing
Chapter 5: Advanced Serverboard Setup5-23Supero Doctor III Interface Display Screen-I (Health Information)5-14 Confi guring Supero Doctor IIIThe Supero
viSUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's ManualTable of ContentsChapter 1 Introduction1-1 Overview ...
5-24SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's ManualNote: SD III Software Revision 1.0 can be downloaded from our Web site at: ftp://ftp
Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform maintenan
6-2SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's ManualFigure 6-2. Chassis Rear View6-2 Control PanelEach control panel on the front of the
Chapter 6: Advanced Chassis Setup6-3Fan Confi gurationIn the 2U Twin2, each node (serverboard) controls the two fans that reside on its side of the cha
6-4SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's ManualInstalling and Removing Hard DrivesInstalling a Hard Drive into the Drive CarrierEmpt
Chapter 6: Advanced Chassis Setup6-5Figure 6-3. Removing a Dummy Drive Tray1111Installing/Removing Hot-swap DrivesTo remove a carrier, push the relea
6-6SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's ManualFigure 6-5. Removing a Hard DriveFigure 6-6. Drives and Nodes: Logical Confi guration
Chapter 6: Advanced Chassis Setup6-76-5 Node Installation/RemovalAs with any server system, power must be removed from the serverboard when upgrading
6-8SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's ManualFigure 6-7. Removing a System Node1212131312
Chapter 6: Advanced Chassis Setup6-96-6 Installing the Air ShroudsAir ShroudsAir shrouds concentrate airfl ow to maximize fan effi ciency. The SC827 ch
viiTable of ContentsRemoving the Protective Film ... 2-42-4 Rack Mounting Instr
6-10SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's ManualPush the new power supply module into the power bay until you hear a click. 5. Recon
Chapter 6: Advanced Chassis Setup6-11Release TabFigure 6-8. Removing the Power Supply
6-12SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's ManualNotes
Chapter 7: BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the AMI BIOS Setup Utility for the X8DTT-HEF+/HIBXF+/HIBQF+. The AMI ROM BIOS
7-2SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's ManualStarting the Setup UtilityNormally, the only visible Power-On Self-Test (POST) routin
Chapter 7: BIOS7-3Day MM/DD/YY format. The time is entered in HH:MM:SS format. (Note: The time is in the 24-hour format. For example, 5:30 P.M. appear
7-4SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's Manual7-3 Advanced Setup Confi gurationsUse the arrow keys to select Boot Setup and hit &l
Chapter 7: BIOS7-5Hit 'Del' Message DisplayThis feature displays "Press DEL to run Setup" during POST. The options are Enabled and
7-6SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's ManualC1E SupportSelect Enabled to use the feature of Enhanced Halt State. C1E signifi cantl
Chapter 7: BIOS7-7tion and heat dissipation. Please refer to Intel’s web site for detailed information. The options are Disable (Disable GV3) and Ena
viiiSUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's Manual5-12 Installing Additional Drivers ...
7-8SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's ManualQPI L0s and L1This enables the QPI power state to low power. L0s and L1 are automatic
Chapter 7: BIOS7-9Throttling - Closed Loop/Throttling - Open LoopThrottling improves reliability and reduces power in the processor by automatic volta
7-10SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's ManualNorth Bridge Confi gurationThis feature allows the user to confi gure the settings fo
Chapter 7: BIOS7-11USB 2.0 ControllerSelect Enabled to activate the onboard USB 2.0 controller. The options are Enabled and Disabled.USB 2.0 Controlle
7-12SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's ManualHot Plug (This feature is available when the option-Enabled is selected)Select Enabl
Chapter 7: BIOS7-13Select 0 to allow the AMI BIOS to use PIO mode 0. It has a data transfer rate of 3.3 MB/s. Select 1 to allow the AMI BIOS to use PI
7-14SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's ManualSelect UDMA5 to allow the BIOS to use Ultra DMA mode 5. It has a data transfer rate
Chapter 7: BIOS7-15Load Onboard LAN1 Option ROM/Load Onboard LAN2 Option ROMSelect Enabled to enable the onboard LAN1 or LAN2 Option ROM. This is to b
7-16SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's ManualTerminal TypeThis feature allows the user to select the target terminal type for Con
Chapter 7: BIOS7-17CPU Temperature/System TemperatureThis feature displays current temperature readings for the CPU and the System. The following item
B-1 Installing Windows for a RAID System ...B-1B-2 Installing Windows for a Non-RAID System
7-18SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's ManualUser intervention: If the system buzzer and Overheat LED has activated, take action
Chapter 7: BIOS7-19APIC ACPI SCI IRQWhen this item is set to Enabled, APIC ACPI SCI IRQ is supported by the system. The options are Enabled and Disabl
7-20SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's ManualView BMC System Event LogThis feature displays the BMC System Event Log (SEL). It s
Chapter 7: BIOS7-21IP Address SourceSelect the source of this machine's IP address. If Static is selected, you will need to know and enter manual
7-22SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's ManualSubnet MaskThis item displays the current subnet mask setting for your IPMI connecti
Chapter 7: BIOS7-23DMI Event LogView Event LogUse this option to view the System Event Log.Mark all events as readThis option marks all events as rea
7-24SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's ManualPassword CheckThis item allows you to check a password after it has been entered. Th
Chapter 7: BIOS7-25Hard Disk DrivesThis feature allows the user to specify the boot sequence from all available hard disk drives. The settings are Di
7-26SUPERSERVER SYS-6026TT-H6RF/H6IBXRF/H6IBQRF User's Manual7-6 Exit OptionsSelect the Exit tab from the AMI BIOS Setup Utility screen to enter
Chapter 7: BIOS7-27How to Recover the AMIBIOS Image (-the Main BIOS Block)An AMIBIOS fl ash chip consists of a boot sector block, and a main BIOS code