Supermicro SYS-6016T-GIBQF Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Barebone serveru Supermicro SYS-6016T-GIBQF. Supermicro SYS-6016T-GIBQF server barebone Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 102
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
SUPER
SUPERSERVER 6016T-GTF
S
UPERSERVER 6016T-GIBXF
SUPERSERVER 6016T-GIBQF
USER’S MANUAL
Revision 1.0
®
Zobrazit stránku 0
1 2 3 4 5 6 ... 101 102

Shrnutí obsahu

Strany 1 - SUPER

SUPERSUPERSERVER 6016T-GTFSUPERSERVER 6016T-GIBXFSUPERSERVER 6016T-GIBQFUSER’S MANUALRevision 1.0®

Strany 2 - Release Date: October 7, 2009

1-2SUPERSERVER 6016T-GTF/GIBXF/GIBQF User's Manual1-2 Serverboard FeaturesAt the heart of the SuperServer 6016T-GTF/GIBXF/GIBQF is one X8DTT-F/X8

Strany 3 - Manual Organization

C-2SUPERSERVER 6016T-GTF/GIBXF/GIBQF User's ManualWeight Gross (Bare Bone): 47 lbs. (21.4 kg.) System Cooling Four sets of 4-

Strany 4

C-3Appendix C: System Specifi cationsNotes

Strany 5

C-4SUPERSERVER 6016T-GTF/GIBXF/GIBQF User's Manual(continued from front)The products sold by Supermicro are not intended for and will not be used

Strany 6 - Table of Contents

Chapter 1: Introduction1-3Onboard Controllers/PortsOnboard I/O backpanel ports on each serverboard include one COM port, a VGA port, two USB ports, a

Strany 7 - Chapter 4 System Safety

1-4SUPERSERVER 6016T-GTF/GIBXF/GIBQF User's ManualFigure 1-1. Intel 5520 Chipset:System Block DiagramNote: This is a general block diagram. Ple

Strany 8

Chapter 1: Introduction1-51-3 Server Chassis FeaturesSystem PowerThe SC818GTQ-1400B features a Gold Level 1400W high-effi ciency power supply. The AC

Strany 9 - Introduction

1-6SUPERSERVER 6016T-GTF/GIBXF/GIBQF User's Manual1-4 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose,

Strany 10 - 1-2 Serverboard Features

Chapter 2: Server Installation2-1Chapter 2 Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get your SuperServer up and

Strany 11 - Infi niBand

2-2SUPERSERVER 6016T-GTF/GIBXF/GIBQF User's Manual!!Warnings and Precautions!This product is not suitable for use with visual display work place

Strany 12 - System Block Diagram

Chapter 2: Server Installation2-3Always keep the rack's front door and all panels and components on the servers • closed when not servicing to ma

Strany 13 - 1-3 Server Chassis Features

2-4SUPERSERVER 6016T-GTF/GIBXF/GIBQF User's Manual2-4 Installing the System into a RackThis section provides information on installing the SC818

Strany 14 - 1-4 Contacting Supermicro

Chapter 2: Server Installation2-5Figure 2-2. Installing the Inner Rails111213Installing the Inner Rail ExtensionsThe SC818G chassis includes a set of

Strany 15 - Server Installation

Manual Revision 1.0 Release Date: October 7, 2009Unless you request and receive written permission from Super Micro Computer, Inc., you may not

Strany 16 - Warnings and Precautions!

2-6SUPERSERVER 6016T-GTF/GIBXF/GIBQF User's ManualFigure 2-3. Assembling the Outer RailsAssembling the Outer RailsEach outer rail is in two secti

Strany 17 - Rack Mounting Considerations

Chapter 2: Server Installation2-7Figure 2-4. Installing the Outer Rails to the RackInstalling the Outer Rails onto the RackOuter Rail InstallationAdju

Strany 18

2-8SUPERSERVER 6016T-GTF/GIBXF/GIBQF User's ManualFigure 2-5. Installing the Server into a RackInstalling the Chassis into a Rack (Figure 2-5)Co

Strany 19

Chapter 2: Server Installation2-9Installing the Server into a Telco RackOptional brackets (p/n MCP-290-00016-0N) are needed to install the server to a

Strany 20 - Assembling the Outer Rails

2-10SUPERSERVER 6016T-GTF/GIBXF/GIBQF User's Manual2-5 Checking the Serverboard SetupAfter you install the server in the rack, you will need to

Strany 21

Chapter 2: Server Installation2-11Checking the ComponentsYou may have processors already installed to the serverboard. Each proces-1. sor needs its ow

Strany 22

2-12SUPERSERVER 6016T-GTF/GIBXF/GIBQF User's ManualNote that all power and data cables have been routed in such a way that they 2. do not block t

Strany 23

Chapter 3: System Interface3-1PowerThe main power button is used to apply or remove power from the power supply to the server system. Turning off syst

Strany 24

3-2SUPERSERVER 6016T-GTF/GIBXF/GIQXF User's ManualFigure 3-1. Universal Information LED StatesNote: deactivating the UID LED must be performed i

Strany 25

Chapter 3: System Interface3-313-4 SATA Drive Carrier LEDsGreen:• Each Serial ATA drive carrier has a green LED. When illuminated, this green LED (

Strany 26

PrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the installation an

Strany 27 - System Interface

3-4SUPERSERVER 6016T-GTF/GIBXF/GIQXF User's ManualNotes

Strany 28 - 3-3 Control Panel LEDs

Chapter 4: System Safety4-1Chapter 4 System Safety4-1 Electrical Safety Precautions!Basic electrical safety precautions shall be followed to protect

Strany 29 - 3-4 SATA Drive Carrier LEDs

4-2SUPERSERVER 6016T-GTF/GIBXF/GIBQF User's Manual4-2 General Safety PrecautionsFollow these rules to ensure general safety:Keep the area around

Strany 30

Chapter 4: System Safety4-34-3 ESD PrecautionsElectrostatic Discharge (ESD) is generated by two objects with different electrical charges coming into

Strany 31 - System Safety

4-4SUPERSERVER 6016T-GTF/GIBXF/GIBQF User's Manual4-4 Operating PrecautionsCare must be taken to assure that the chassis cover is in place when t

Strany 32

Chapter 5: Advanced Serverboard Setup5-1Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to install the X8DTT-F/X8DTT-IBXF/X

Strany 33 - 4-3 ESD Precautions

5-2SUPERSERVER 6016T-GTF/GIBXF/GIBQF User's Manual5-2 I/O PortsThe I/O ports are color coded in conformance with the PC 99 specifi cation. See Fi

Strany 34 - BATTERY HOLDER

Chapter 5: Advanced Serverboard Setup5-35-3 Processor and Heatsink InstallationNotes: Always connect the power cord last and always remove it before

Strany 35 - Advanced Serverboard Setup

5-4SUPERSERVER 6016T-GTF/GIBXF/GIBQF User's ManualAfter removing the plastic cap, use 1. your thumb and the index fi nger to hold the CPU at the n

Strany 36 - 4. LAN1 9. UID Button

Chapter 5: Advanced Serverboard Setup5-5Remove power from the system 1. and unplug the AC power cord from the power supply.Do not apply any thermal gr

Strany 37 - Installing LGA1366 Processors

SUPERSERVER 6016T-GTF/GIBXF/GIBQF User's ManualivChapter 4: System SafetyYou should thoroughly familiarize yourself with this chapter for a gene

Strany 38 - Load Plate

5-6SUPERSERVER 6016T-GTF/GIBXF/GIBQF User's ManualRemove power from the system 1. and unplug the AC power cord from the power supply.Using a scre

Strany 39 - Installing a CPU Heatsink

Chapter 5: Advanced Serverboard Setup5-75-4 Installing MemoryMemory SupportEach X8DTT-F/X8DTT-IBXF/X8DTT-IBQF has twelve 240-pin DIMM slots that can s

Strany 40 - Removing the Heatsink

5-8SUPERSERVER 6016T-GTF/GIBXF/GIBQF User's ManualTo Install: Insert module vertically and press down until it snaps into place. Pay attention to

Strany 41 - 5-4 Installing Memory

Chapter 5: Advanced Serverboard Setup5-95-5 Adding PCI CardsPCI Express SlotThe 6016T-GTF/IBXF/IBQF includes one preinstalled riser card designed spe

Strany 42 - Front View

5-10SUPERSERVER 6016T-GTF/GIBXF/GIBQF User's ManualFigure 5-3. X8DTT Series Serverboard Layout5-6 Serverboard DetailsJF1LE4SW1JWR2JWR1FAN2FAN1FAN

Strany 43 - 5-5 Adding PCI Cards

Chapter 5: Advanced Serverboard Setup5-11X8DTT-F/X8DTT-IBXF/X8DTT-IBQF Quick ReferenceJumper Description Default SettingJBT1 CMOS Clear (See Section 5

Strany 44 - 5-6 Serverboard Details

5-12SUPERSERVER 6016T-GTF/GIBXF/GIBQF User's ManualReset ConnectorThe reset connector is located on pins 3 and 4 of JF1 and attaches to the reset

Strany 45 - LED Description

Chapter 5: Advanced Serverboard Setup5-13NIC2 (LAN2) LEDThe LED connections for LAN2 are on pins 9 and 10 of JF1. Attach LAN LED cables to display net

Strany 46 - 5-7 Connector Defi nitions

5-14SUPERSERVER 6016T-GTF/GIBXF/GIBQF User's ManualUniversal Serial Bus (USB)Two Universal Serial Bus ports are located on the I/O panel. Two USB

Strany 47

Chapter 5: Advanced Serverboard Setup5-15Serial PortsOne serial port is included on the serverboard. The COM port is located beside the VGA port. See

Strany 48

vPrefaceNotes

Strany 49

5-16SUPERSERVER 6016T-GTF/GIBXF/GIBQF User's Manual5-8 Jumper SettingsTo modify the operation of the serverboard, jumpers can be used to choose b

Strany 50 - 5-8 Jumper Settings

Chapter 5: Advanced Serverboard Setup5-17Watch Dog Enable/DisableJWD1 enables the Watch Dog func-tion, a system monitor that takes action when a softw

Strany 51

5-18SUPERSERVER 6016T-GTF/GIBXF/GIBQF User's Manual5-9 Onboard IndicatorsLAN1/LAN2 LEDsThe Ethernet ports (located beside the COM port) have two

Strany 52 - 5-9 Onboard Indicators

Chapter 5: Advanced Serverboard Setup5-19Driver/Tool Installation Display ScreenNote: Click the icons showing a hand writing on the paper to view the

Strany 53

5-20SUPERSERVER 6016T-GTF/GIBXF/GIBQF User's ManualSupero Doctor III Interface Display Screen-I (Health Information)5-11 Confi guring Supero Docto

Strany 54

Chapter 5: Advanced Serverboard Setup5-21Note: SD III Software Revision 1.0 can be downloaded from our Web site at: ftp://ftp.supermicro.com/utility/S

Strany 55

5-22SUPERSERVER 6016T-GTF/GIBXF/GIBQF User's ManualNotes

Strany 56

Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform mainte-na

Strany 57 - Advanced Chassis Setup

6-2SUPERSERVER 6016T-GTF/GIBXF/GIBQF User's ManualFigure 6-1. Chassis: Front and Rear Views6-2 Control PanelThe control panel (located on the fr

Strany 58 - 6-3 System Cooling

Chapter 6: Advanced Chassis Setup6-3System Fan FailureFan speed is controlled by system temperature via a BIOS setting. If a fan fails, the remaining

Strany 59 - System Fan Failure

viSUPERSERVER 6016T-GTF/GIBXF/GIBQF User's ManualTable of ContentsChapter 1 Introduction1-1 Overview ...

Strany 60 - Hard Drive Installation

6-4SUPERSERVER 6016T-GTF/GIBXF/GIBQF User's Manual6-4 Drive Bay Installation/RemovalAccessing the Drive BaysHard Drives: Because of their hotswa

Strany 61

Chapter 6: Advanced Chassis Setup6-5Figure 6-3. Removing a Hard Drive CarrierWarning: Except for short periods of time (swapping hard drives), do not

Strany 62

6-6SUPERSERVER 6016T-GTF/GIBXF/GIBQF User's ManualInstalling a Hard Drive to the Hard Drive CarrierRemove the two screws securing the dummy drive

Strany 63 - Peripheral Drive Installation

Chapter 6: Advanced Chassis Setup6-7Note: When installing the hard drive carrier that is next to the power supply, the power supply handle must be lif

Strany 64

6-8SUPERSERVER 6016T-GTF/GIBXF/GIBQF User's Manual6-5 Installing the Air ShroudAir shrouds concentrate airfl ow to maximize fan effi ciency. The a

Strany 65 - 6-6 Power Supply

Chapter 6: Advanced Chassis Setup6-96-6 Power SupplyThe system includes a single 1400 watt power supply, which is auto-switching capa-ble. Power must

Strany 66

6-10SUPERSERVER 6016T-GTF/GIBXF/GIBQF User's ManualNotes

Strany 67 - Chapter 7

Chapter 7: BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the AMI BIOS Setup Utility for the X8DTT-F/-IBXF/-IBQF. The AMI ROM BIOS is st

Strany 68 - 7-2 Main Setup

7-2SUPERSERVER 6016T-GTF/GIBXF/GIBQF User's ManualStarting the Setup UtilityNormally, the only visible Power-On Self-Test (POST) routine is the m

Strany 69

Chapter 7: BIOS7-3Supermicro X8DTT/-F/-IBX/-IBXF/-IBQ/-IBQFBIOS Build Version• : This item displays the BIOS revision used in your sys-tem.BIOS Build

Strany 70 - XBOOT Features

viiTable of ContentsInstalling the Server into a Telco Rack ... 2-92-5 Checking the Serverboa

Strany 71 - Processor and Clock Options

7-4SUPERSERVER 6016T-GTF/GIBXF/GIBQF User's Manual7-3 Advanced Setup Confi gurationsUse the arrow keys to select Boot Setup and hit <Enter>

Strany 72

Chapter 7: BIOS7-5Hit 'Del' Message DisplayThis feature displays "Press DEL to run Setup" during POST. The options are Enabled and

Strany 73 - XCPU Bridge Confi guration

7-6SUPERSERVER 6016T-GTF/GIBXF/GIBQF User's ManualC1E SupportSelect Enabled to use the feature of Enhanced Halt State. C1E signifi cantly reduces

Strany 74

Chapter 7: BIOS7-7tion and heat dissipation. Please refer to Intel’s web site for detailed information. The options are Disable (Disable GV3) and Ena

Strany 75 - XNorth Bridge Confi guration

7-8SUPERSERVER 6016T-GTF/GIBXF/GIBQF User's ManualQPI L0s and L1This enables the QPI power state to low power. L0s and L1 are automatically selec

Strany 76 - XSouthBridge Confi guration

Chapter 7: BIOS7-9Guardband Temperature (For the Closed Loop only)This is the temperature which applies to the DIMM temperature threshold. Each step

Strany 77 - IDE/SATA Confi guration

7-10SUPERSERVER 6016T-GTF/GIBXF/GIBQF User's ManualIntel VT-dSelect Enabled to enable Intel's Virtualization Technology support for Direct I

Strany 78

Chapter 7: BIOS7-11Hand-Off support. When enabled, the EHCI Interface will be changed from the BIOS-controlled to the OS-controlled. The options are D

Strany 79 - XPCI/PnP Confi guration

7-12SUPERSERVER 6016T-GTF/GIBXF/GIBQF User's Manualis not used. Block Mode allows transfers of up to 64 KB per interrupt. Select Disabled to allo

Strany 80 - XRemote Access Confi guration

Chapter 7: BIOS7-13Select UDMA0 to allow the BIOS to use Ultra DMA mode 0. It has a data transfer rate of 16.6 MBs. It has the same transfer rate as P

Strany 81 - Hardware Health Monitor

viiiSUPERSERVER 6016T-GTF/GIBXF/GIBQF User's ManualChapter 6 Advanced Chassis Setup6-1 Static-Sensitive Devices ...

Strany 82

7-14SUPERSERVER 6016T-GTF/GIBXF/GIBQF User's ManualPCI IDE BusMasterWhen enabled, the BIOS uses PCI bus mastering for reading/writing to IDE driv

Strany 83 - XACPI Confi guration

Chapter 7: BIOS7-15Redirection After BIOS POSTSelect Disabled to turn off Console Redirection after Power-On Self-Test (POST). Select Always to keep C

Strany 84 - View BMC System Event Log

7-16SUPERSERVER 6016T-GTF/GIBXF/GIBQF User's Manualand system cooling. In both the alarms above, please take immediate action as shown below. (Se

Strany 85 - Set LAN Confi guration

Chapter 7: BIOS7-17Notes: The system may shut down if it continues for a long period to prevent damage to the CPU. The information provided above is f

Strany 86 - IP Address Confi guration

7-18SUPERSERVER 6016T-GTF/GIBXF/GIBQF User's ManualSelect to Enabled to allow USB devices to wakeup from S3/S4 state. The options are Enabled and

Strany 87 - MAC Address Confi guration

Chapter 7: BIOS7-19SEL Entry Number• SEL Record ID• SEL Record Type• Timestamp, Generator ID• Event Message Format User• Event Sensor Type• Event Sens

Strany 88 - SEL PEF Confi guration

7-20SUPERSERVER 6016T-GTF/GIBXF/GIBQF User's ManualChannel Number - Enter the channel number for the SET LAN Confi g com-mand. This is initially

Strany 89 - XDMI Event Log

Chapter 7: BIOS7-21IP Address The BIOS will automatically enter the IP address of this machine; however it may be over-ridden. IP addresses are 6 two-

Strany 90 - 7-4 Security Settings

7-22SUPERSERVER 6016T-GTF/GIBXF/GIBQF User's ManualXSubnet Mask Confi guration Subnet masks tell the network which subnet this machine belongs to.

Strany 91 - 7-5 Boot Confi guration

Chapter 7: BIOS7-23Specifi cation for more information at www.intel.com. The options are No Delay, 30 sec, 60 sec, 1.5 min, 2.0 min.Startup Delay - Th

Strany 92 - 7-6 Exit Options

Chapter 1 Introduction1-1 OverviewThe SuperServer 6016T-GTF/GIBXF/GIBQF is a 1U server comprised of the SC818GTQ-1400B chassis and one X8DTT-F/X8DTT-I

Strany 93

7-24SUPERSERVER 6016T-GTF/GIBXF/GIBQF User's Manual7-4 Security SettingsThe AMI BIOS provides a Supervisor and a User password. If you use both p

Strany 94

Chapter 7: BIOS7-25Clear User Password (Available only if User Password has been set)This item allows you to clear a user password after it has been e

Strany 95 - BIOS Error Beep Codes

7-26SUPERSERVER 6016T-GTF/GIBXF/GIBQF User's ManualXHard Disk DrivesThis feature allows the user to specify the boot sequence from all available

Strany 96

Chapter 7: BIOS7-27Save Changes and ExitWhen you have completed the system confi guration changes, select this option to leave the BIOS Setup Utility a

Strany 97 - Installing Windows

7-28SUPERSERVER 6016T-GTF/GIBXF/GIBQF User's ManualNotes

Strany 98

A-1Appendix A: BIOS Error Beep CodesAppendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the

Strany 99 - System Specifi cations

A-2SUPERSERVER 6016T-GTF/GIBXF/GIQXF User's ManualNotes

Strany 100

Appendix B: Installing WindowsB-1Appendix B Installing Windows After all hardware components have been installed, you must fi rst confi gure Intel South

Strany 101

B-2SUPERSERVER 6016T-GTF/GIBXF/GIBQF User's ManualB-2 Installing Windows to a Non-RAID SystemInsert Microsoft's Windows OS Setup CD in the

Strany 102

C-1Appendix C: System Specifi cationsAppendix C System Specifi cationsProcessors Two Intel® 5500 Series processors in LGA1366 sockets Note: p

Komentáře k této Příručce

Žádné komentáře