Supermicro SYS-6028R-T Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Barebone serveru Supermicro SYS-6028R-T. Supermicro SuperServer 6028R-T Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 128
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků

Shrnutí obsahu

Strany 1 - SUPER

SUPERSERVER® 6028R-T6028R-TT SUPER®USER’S MANUAL 1.0

Strany 2 - Release Date: August 7, 2014

1-2SUPERSERVER 6028R-T/TT User's Manual1-2 Serverboard FeaturesAt the heart of the SuperServer 6028R-T/TT lies the X10DRi/X10DRi-T, a dual proce

Strany 3 - Manual Organization

7-16SUPERSERVER 6028R-T/TT User's ManualPort 0 ~ Port 5 Hot PlugSelect Enabled to enable hot-plugging support for a port specied by the user, wh

Strany 4

Chapter 7: BIOS7-17•Software Preserve Support sSATA Port 0~ Port 3Select Enabled to enable an sSATA port specied by the user. The options are Disabl

Strany 5

7-18SUPERSERVER 6028R-T/TT User's ManualsSATA RAID Option ROM/UEFI DriverSelect EFI to load the EFI driver for system boot. Select Legacy to load

Strany 6 - Table of Contents

Chapter 7: BIOS7-19•ME Firmware Status #2•Current State•Error CodeAltitudeThis feature indicates the altitude of the platform this machine is locat

Strany 7

7-20SUPERSERVER 6028R-T/TT User's ManualAbove 4G Decoding (Available if the system supports 64-bit PCI decoding)Select Enabled to decode a PCI de

Strany 8

Chapter 7: BIOS7-21Onboard LAN Option ROM TypeSelect Enabled to enable Option ROM support to boot the computer using a device installed on the slot sp

Strany 9 - Introduction

7-22SUPERSERVER 6028R-T/TT User's ManualDevice ModeUse this feature to congure SUART clock source settings. The options are 24MHz/13

Strany 10 - 1-2 Serverboard Features

Chapter 7: BIOS7-23is odd. Select None if you do not want to send a parity bit with your data bits in transmission. Select Mark to add a mark as a par

Strany 11 - 1-3 Server Chassis Features

7-24SUPERSERVER 6028R-T/TT User's ManualSOL/COM2Console RedirectionSelect Enabled to use the SOL port for Console Redirection. The options are En

Strany 12 - FAN SPEED

Chapter 7: BIOS7-25Flow ControlUse this feature to set the ow control for Console Redirection to prevent data loss caused by buffer overow. Send a &

Strany 13 - 1-4 Contacting Supermicro

1-3Chapter 1: Introduction1-3 Server Chassis FeaturesThe SC823T-653LPB is a 2U chassis that features six 3.5" hot-swap hard drive bays and a hig

Strany 14

7-26SUPERSERVER 6028R-T/TT User's Manual*If the item above set to Enabled, the following items will become available for user's conguration

Strany 15 - Server Installation

Chapter 7: BIOS7-27Trusted Computing (Available when a TPM device is installed and detected by the BIOS)CongurationSecurity Device SupportIf this f

Strany 16 - 2-4 Warnings and Precautions

7-28SUPERSERVER 6028R-T/TT User's ManualACPI Settings WHEA SupportSelect Enabled to support the Windows Hardware Error Architecture (WHEA) plat-

Strany 17 - Rack Mounting Considerations

Chapter 7: BIOS7-297-4 Event LogsUse this feature to congure Event Log settings.Change SMBIOS Event Log SettingsThis feature allows the user to co

Strany 18 - SUPERSERVER 6028R-T/TT Manual

7-30SUPERSERVER 6028R-T/TT User's ManualMemory Correctable Error ThresholdUse this item to enter the threshold value for correctable memory error

Strany 19 - Installing the Rack Rails

Chapter 7: BIOS7-317-5 IPMIUse this feature to congure Intelligent Platform Management Interface (IPMI) settings. IPMI Firmware RevisionTh

Strany 20

7-32SUPERSERVER 6028R-T/TT User's ManualWhen SEL is FullThis feature allows the user to determine what the BIOS should do when the sys-tem event

Strany 21

Chapter 7: BIOS7-33Gateway IP AddressThis item displays the Gateway IP address for this computer. This should be in decimal and in dotted quad form (i

Strany 22

7-34SUPERSERVER 6028R-T/TT User's Manual7-6 Security SettingsThis menu allows the user to congure the following security settings fo

Strany 23 - System Interface

Chapter 7: BIOS7-357-7 Boot SettingsUse this feature to congure Boot Settings:Boot Mode SelectUse this item to select the type of device to be used

Strany 24 - 3-3 Control Panel LEDs

1-4SUPERSERVER 6028R-T/TT User's ManualFigure 1-1. Chipset Block DiagramNote: This is a general block diagram. Please see Chapter 5 for details.

Strany 25 - 3-4 Drive Carrier LEDs

7-36SUPERSERVER 6028R-T/TT User's Manual•Dual Boot Order #10•Dual Boot Order #11•Dual Boot Order #12•Dual Boot Order #13•Dual Boot Order #14

Strany 26

Chapter 7: BIOS7-377-8 Save & ExitSelect the Save & Exit tab from the BIOS setup screen to congure the settings below.Discard

Strany 27 - Chapter 4

7-38SUPERSERVER 6028R-T/TT User's ManualRestore DefaultsTo set this feature, select Restore Defaults from the Exit menu and press <Enter>.

Strany 28

A-1Appendix A: BIOS Error Beep CodesAppendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed at each syst

Strany 29

A-2SUPERSERVER 6028R-T/TT User's ManualNotes

Strany 30 - Installation Instructions

B-1Appendix B: System SpecicationsAppendix B System SpecicationsProcessorsSingle or dual Intel® E5-2600 Series (V3) Socket R3 processors in LGA 20

Strany 31 - Circuit Breaker

B-2SUPERSERVER 6028R-T/TT User's ManualChassisSC823T-653LPB (2U rackmount)Dimensions: (WxHxD) 16.8 x 3.5 x 25.6 in. (427 x 89 x 650 mm)WeightGros

Strany 32 - Power Disconnection Warning

B-3Appendix B: System SpecicationsDisclaimer (continued from front)The products sold by Supermicro are not intended for and will not be used in life

Strany 33 - ילמשח קותינ ינפמ הרהזא

B-4SUPERSERVER 6028R-T/TT User's ManualNotes

Strany 34 - Equipment Installation

1-5Chapter 1: Introduction1-4 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131 U.S.A.Tel: +1 (408

Strany 35 - Restricted Area

1-6SUPERSERVER 6028R-T/TT User's ManualNotes

Strany 36 - Battery Handling

Chapter 2: Server Installation2-1Chapter 2 Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get your SuperServer 6028

Strany 37

2-2SUPERSERVER 6028R-T/TT Manual•This product is for installation only in a Restricted Access Location (dedicated equipment rooms, service closets an

Strany 38 - Redundant Power Supplies

Chapter 2: Server Installation2-3Rack Mounting ConsiderationsAmbient Operating TemperatureIf installed in a closed or multi-unit rack assembly, the am

Strany 39 - Backplane Voltage

2-4SUPERSERVER 6028R-T/TT Manual2-5 Installing the System into a RackThis section provides information on installing the SuperServer 6028R-T/TT into

Strany 40

Chapter 2: Server Installation2-5Installing the Chassis RailsPosition one of the xed chassis rail sections you just removed along the side of the 602

Strany 41 - Product Disposal

The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccur

Strany 42 - Hot Swap Fan Warning

2-6SUPERSERVER 6028R-T/TT ManualFigure 2-3. Installing the Server into a RackInstalling the Server into the RackYou should now have rails attached to

Strany 43

Chapter 2: Server Installation2-7Figure 2-4. Installing the Server into a Telco RackInstalling the Server into a Telco RackIf you are installing the

Strany 44 - Power Cable and AC Adapter

2-8SUPERSERVER 6028R-T/TT ManualNotes

Strany 45 - (UL/CSA  )

Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are several LEDs on the control panel as well as others on the drive carri

Strany 46

SUPERSERVER 6028R-T/TT User's Manual3-2PowerIndicates power is being supplied to the system's power supply units. This LED should normally b

Strany 47 - Advanced Serverboard Setup

Chapter 3: System Interface3-3Information LEDThis LED will be solid blue when the UID function has been activated.When this LED ashes red, it indicat

Strany 48 - •Control Panel cable (JF1)

SUPERSERVER 6028R-T/TT User's Manual3-4Notes

Strany 49 - 5-3 I/O Ports

4-1Chapter 4: Warning Statements for AC SystemsChapter 4 Standardized Warning Statements for AC Systems4-1 About Standardized Warning StatementsThe

Strany 50 - WARNING!

4-2SUPERSERVER 6028R-T/TT User's ManualWarnung WICHTIGE SICHERHEITSHINWEISEDieses Warnsymbol bedeutet Gefahr. Sie benden sich in einer Si

Strany 51

4-3Warning Statements for AC Systems안전을 위한 주의사항경고!이 경고 기호는 위험이 있음을 알려 줍니다. 작업자의 신체에 부상을 야기 할 수 있는 상태에 있게 됩니다. 모든 장비에 대한 작업을 수행하기 전에 전기회로와 관련된 위험요소들을 확

Strany 52

iiiPrefacePrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the insta

Strany 53 - Installing a CPU Heatsink

4-4SUPERSERVER 6028R-T/TT User's ManualInstallation Instructions Warning!Read the installation instructions before connecting the system to the p

Strany 54 - 5-5 Installing Memory

4-5Chapter 4: Warning Statements for AC SystemsCircuit Breaker Warning!This product relies on the building's installation for short-circuit (over

Strany 55

4-6SUPERSERVER 6028R-T/TT User's ManualPower Disconnection Warning 電源切断の警告システムコンポーネントの取り付けまたは取り外しのために、シャーシー内部にアクセスするには、システムの電源はすべてのソースから切断され、電源コー

Strany 56 - 5-6 Adding PCI Add-On Cards

4-7Chapter 4: Warning Statements for AC Systems¡Advertencia! El sistema debe ser disconnected de todas las fuentes de energía y del cable eléctrico qu

Strany 57 - X10DRi-(T)

4-8SUPERSERVER 6028R-T/TT User's ManualEquipment Installation機器の設置トレーニングを受け認定された人だけがこの装置の設置、交換、またはサービスを許可されています。 Warning!Only trained and qualie

Strany 58

4-9Chapter 4: Warning Statements for AC Systemsアクセス制限区域このユニットは、アクセス制限区域に設置されることを想定しています。アクセス制限区域は、特別なツール、鍵と錠前、その他のセキュリティの手段を用いてのみ出入りが可能です。 Warning!Thi

Strany 59

4-10SUPERSERVER 6028R-T/TT User's ManualBattery Handling Warning!There is the danger of explosion if the battery is replaced incorrectly. Replace

Strany 60 - 5-8 Connector Denitions

4-11Chapter 4: Warning Statements for AC SystemsWarnung Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr. Ersetzen Sie die Batterie nur

Strany 61

4-12SUPERSERVER 6028R-T/TT User's ManualWarnung Dieses Gerät kann mehr als eine Stromzufuhr haben. Um sicherzustellen, dass der Einheit kein trom

Strany 62

4-13Chapter 4: Warning Statements for AC SystemsBackplane Voltageバックプレーンの電圧システムの稼働中は危険な電圧または電力が、バックプレーン上にかかっています。修理する際には注意ください。警告当系统正在进行时,背板上有很危险的电压或能

Strany 63

SUPERSERVER 6028R-T/TT User's Manualivto this chapter when adding or removing processors or main memory and when reconguring the serverboard.Cha

Strany 64

4-14SUPERSERVER 6028R-T/TT User's ManualComply with Local and National Electrical Codes Warning!Installation of the equipment must comply with lo

Strany 65 - Pin # Denition

4-15Chapter 4: Warning Statements for AC SystemsProduct Disposal Warning!Ultimate disposal of this product should be handled according to all national

Strany 66 - 5-9 Jumper Settings

4-16SUPERSERVER 6028R-T/TT User's ManualWaarschuwing De uiteindelijke verwijdering van dit product dient te geschieden in overeenstemming met all

Strany 67

4-17Chapter 4: Warning Statements for AC SystemsWarnungDie Lüfter drehen sich u. U. noch, wenn die Lüfterbaugruppe aus dem Chassis genommen wird. Halt

Strany 68

4-18SUPERSERVER 6028R-T/TT User's Manual Warning!When installing the product, use the provided or designated connection cables, power cables and

Strany 69 - X8DT3/i-F/-LN4F

4-19Chapter 4: Warning Statements for AC SystemsAttention Lors de l'installation du produit, utilisez les bables de connection fournis ou désigné

Strany 70 - 5-11 SATA Ports

4-20SUPERSERVER 6028R-T/TT User's ManualNotes

Strany 71 - 5-12 Installing Software

Chapter 5: Advanced Serverboard Setup5-1Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to connect the data and power cab

Strany 72 - SuperDoctor® 5

5-2SUPERSERVER 6028R-T/6028R-TT User's ManualUnpackingThe serverboard is shipped in antistatic packaging to avoid electrical static dis-charge. W

Strany 73 - 5-13 Onboard Battery

Chapter 5: Advanced Serverboard Setup5-35-3 I/O PortsThe I/O ports are located on the backplane of the motherboard. See Figure 5-2 below for the desc

Strany 74

vPrefaceNotes

Strany 75 - Advanced Chassis Setup

5-4SUPERSERVER 6028R-T/6028R-TT User's Manual1. There are two levers on the LGA2011 socket. First press and release the load lever labeled &apos

Strany 76 - Unpacking

Chapter 5: Advanced Serverboard Setup5-5Gently push down to pop the load plate open.3. With the lever labeled 'Close 1st' fully retracted,

Strany 77 - 6-3 System Fans

5-6SUPERSERVER 6028R-T/6028R-TT User's ManualWarning: You can only install the CPU to the socket in one direction. Make sure that the CPU is pro

Strany 78 - Accessing the Drive Bays

Chapter 5: Advanced Serverboard Setup5-71. Unplug the power cord from the power supply.2. Unscrew and remove the heatsink screws in the sequence sho

Strany 79 - SATA Drive Installation

5-8SUPERSERVER 6028R-T/6028R-TT User's ManualMemory SupportThe X10DRi/X10DRi-T supports up to 1 TB of DDR4-2133/1866/1600/1333 RDIMM ECC memory (

Strany 80 - Release Button

Chapter 5: Advanced Serverboard Setup5-9Processor & Memory Module Population CongurationFor memory to work properly, follow the tables below for

Strany 81

5-10SUPERSERVER 6028R-T/6028R-TT User's Manual5-6 Adding PCI Add-On CardsA total of six PCI expansion (add-on) cards can be installed into the s

Strany 82 - DVD-ROM Drive Installation

Chapter 5: Advanced Serverboard Setup5-11Figure 5-4. X10DRi/X10DRi-T Layout(not drawn to scale)5-7 Serverboard DetailsJPI2C1JPWR1JPWR2JOH1JL1JSD1JSD2

Strany 83 - 6-5 Power Supply

5-12SUPERSERVER 6028R-T/6028R-TT User's ManualX10DRi/X10DRi-T Quick ReferenceJumper Description Default SettingJBR1 BIOS Recovery Enable/Disable

Strany 84

Chapter 5: Advanced Serverboard Setup5-13(CPU2) Slot5 PCI-Express 3.0 x8 Slot from CPU2(CPU2) Slot6 PCI-Express 3.0 x16 Slot from CPU2(T-)SGPIO1/2/3 S

Strany 85 - Chapter 7

viTable of ContentsChapter 1 Introduction1-1 Overview ...

Strany 86 - 7-2 Main Setup

5-14SUPERSERVER 6028R-T/6028R-TT User's ManualReset ButtonThe Reset Button connection is located on pins 3 and 4 of JF1 and attaches to the reset

Strany 87

Chapter 5: Advanced Serverboard Setup5-15HDD LEDThe HDD LED connection is located on pins 13 and 14 of JF1. Attach a cable to Pin 14 to show HDD activ

Strany 88 - Boot Feature

5-16SUPERSERVER 6028R-T/6028R-TT User's ManualFan HeadersThere are eight fan headers on the serverboard (Fan 1-Fan 6, Fan A, Fan B), all of which

Strany 89 - Power Conguration

Chapter 5: Advanced Serverboard Setup5-17Internal SpeakerThe Internal Speaker, located at SP1, can be used to provide audible indica-tions for various

Strany 90 - CPU Conguration

5-18SUPERSERVER 6028R-T/6028R-TT User's ManualStandby PowerThe Standby Power header is located at JSTBY1 on the serverboard. See the table on

Strany 91 - IIO1 Conguration

Chapter 5: Advanced Serverboard Setup5-19Universal Serial Bus (USB)Two USB 2.0 ports (USB 0/1) and two USB 2.0/3.0 ports (USB12/13) are lo-cated on th

Strany 92 - IOAT Conguration

5-20SUPERSERVER 6028R-T/6028R-TT User's Manual5-9 Jumper SettingsExplanation of JumpersTo modify the operation of the serverboard, jumpers can b

Strany 93

Chapter 5: Advanced Serverboard Setup5-21CMOS ClearJBT1 is used to clear CMOS (which will also clear any passwords). Instead of pins, this jumper con

Strany 94 - Memory Conguration

5-22SUPERSERVER 6028R-T/6028R-TT User's ManualI2C to PCI-E SlotsJumper SettingsJumper Setting Denition Pins 1-2 EnabledPins 2-3 Disabled

Strany 95 - •P1 DIMMD1

Chapter 5: Advanced Serverboard Setup5-235-10 Onboard IndicatorsLAN LEDsThe Ethernet ports (located beside the VGA port) have two LEDs. On each port,

Strany 96 - •USB Devices

viiTable of ContentsReset ... 3-1Power ...

Strany 97

5-24SUPERSERVER 6028R-T/6028R-TT User's Manual5-11 SATA PortsSATA PortPin DenitionsPin# Denition Pin Denition1 Ground 2 TXP3

Strany 98

Chapter 5: Advanced Serverboard Setup5-255-12 Installing SoftwareThe Supermicro ftp site contains drivers and utilities for your system at ftp://ftp.

Strany 99

5-26SUPERSERVER 6028R-T/6028R-TT User's ManualSuperDoctor® 5The Supermicro SuperDoctor 5 is a program that functions in a command-line or web-bas

Strany 100

Chapter 5: Advanced Serverboard Setup5-27Figure 5-7. Installing the Onboard BatteryORPlease handle used batteries carefully. Do not damage the battery

Strany 101 - •Software Preserve Support

5-28SUPERSERVER 6028R-T/6028R-TT User's ManualNotes

Strany 102

Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform main-te

Strany 103 - •PCI Latency Timer

6-2SUPERSERVER 6028R-T/TT User's ManualFigure 6-1. Chassis: Front and Rear ViewsIO Panel (see Figure 5-3)Low Prole PCI SlotsControl PanelSATA Dr

Strany 104

Chapter 6: Advanced Chassis Setup6-36-2 Control PanelThe control panel (located on the front of the chassis) must be connected to the JF1 connector o

Strany 105 - Super IO Conguration

6-4SUPERSERVER 6028R-T/TT User's ManualFigure 6-2. System Fan Removal6-4 Drive Bay Installation/RemovalAccessing the Drive BaysYou do not need

Strany 106 - Console Redirection Settings

Chapter 6: Advanced Chassis Setup6-5Figure 6-3. Mounting a Drive in a CarrierCaution: Regardless of how many hard drives are installed, all drive car

Strany 107

viiiSUPERSERVER 6028R-T/TT User's ManualDIMM Installation ...

Strany 108

6-6SUPERSERVER 6028R-T/TT User's ManualFigure 6-4. Removing SATA DrivesInstalling/Removing Hot-swap SATA Drives1. Push the release button on th

Strany 109

Chapter 6: Advanced Chassis Setup6-7Installing a Component in the 5.25" Drive BayA single 5.25" drive bay is located in the front of the cha

Strany 110

6-8SUPERSERVER 6028R-T/TT User's ManualDVD-ROM Drive InstallationThe top cover of the chassis must be opened to gain full access to the DVD-ROM.

Strany 111

Chapter 6: Advanced Chassis Setup6-96-5 Power SupplyThe SuperServer 6028R-T/TT has a single 650 watt power supply. This power supply module has an au

Strany 112 - Change Attempt Order

6-10SUPERSERVER 6028R-T/TT User's ManualNotes

Strany 113 - 7-4 Event Logs

Chapter 7: BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the AMI BIOS setup utility for the X10DRi/X10DRi-T. The ROM BIOS is stored

Strany 114

7-2SUPERSERVER 6028R-T/TT User's ManualHow to Start the Setup UtilityNormally, the only visible Power-On Self-Test (POST) routine is the memory t

Strany 115 - 7-5 IPMI

Chapter 7: BIOS7-3The following Main menu items will be displayed:System Date/System Time Use this option to change the system date and time. Highligh

Strany 116 - BMC Network Conguration

7-4SUPERSERVER 6028R-T/TT User's Manual7-3 Advanced Setup CongurationsUse the arrow keys to select Advanced setup and press <Enter> to a

Strany 117

Chapter 7: BIOS7-5Wait For 'F1' If ErrorSelect Enabled to force the system to wait until the 'F1' key is pressed if an error occur

Strany 118 - 7-6 Security Settings

Chapter 1 Introduction1-1 OverviewThe SuperServer 6028R-T/TT is a high-end server comprised of two main sub-systems: the SC823T-653LPB 2U server cha

Strany 119 - 7-7 Boot Settings

7-6SUPERSERVER 6028R-T/TT User's ManualCPU CongurationNorth BridgeThis feature allows the user to congure the settings for the Intel North Br

Strany 120

Chapter 7: BIOS7-7The following items will be display:PCI-E Port Link StatusPCI-E Port Link MaxPCI-E Port Link SpeedPCI-E Port L0s Exit LatencyUse thi

Strany 121 - 7-8 Save & Exit

7-8SUPERSERVER 6028R-T/TT User's ManualNo PCIe Port Active ECOUse this feature to select a workaround setting to implement the engineering-change

Strany 122

Chapter 7: BIOS7-9Coherency Support (Isoch)Select Enable for the Iscoh VT-d engine to pass through ATS to enhance system performance. The options are

Strany 123 - BIOS Error Beep Codes

7-10SUPERSERVER 6028R-T/TT User's ManualMemory CongurationEnforce PORSelect Enable to enforce POR restrictions on DDR4 frequency and voltage pr

Strany 124

Chapter 7: BIOS7-11Rank InterleavingUse this item to select a rank memory interleaving method. The options are Auto, 1-Way, 2-Way, 4-Way, and 8-Way.A7

Strany 125 - System Specications

7-12SUPERSERVER 6028R-T/TT User's Manualwrite back one cache line every 16K cycles, if there is no delay caused by internal processing. By using

Strany 126

Chapter 7: BIOS7-13XHCI Hand-OffThis is a work-around solution for operating systems that do not support XHCI (Ex-tensible Host Controller Interface)

Strany 127

7-14SUPERSERVER 6028R-T/TT User's ManualSATA CongurationWhen this submenu is selected, AMI BIOS automatically detects the presence of the SATA

Strany 128

Chapter 7: BIOS7-15Port 0 ~ Port 5 SATA Device TypeUse this item to specify if the SATA port specied by the user should be con-nected to

Komentáře k této Příručce

Žádné komentáře