SUPERSUPERSERVER 5016I-M6FUSER’S MANUALRevision 1.0®
NotesxSUPERSERVER 5016I-M6F User's Manual
C-2SUPERSERVER 5016I-M6F User's ManualChassis Model: SC813MTS-350C (1U Rackmount) Dimensions: (WxHxD) 17.2 x 1.7 x 19.85 in. (437 x 4
C-3Appendix C: System Specifi cationsNotes
C-4SUPERSERVER 5016I-M6F User's Manual(continued from front)The products sold by Supermicro are not intended for and will not be used in life sup
Chapter 1 Introduction1-1 OverviewThe SuperServer 5016I-M6F is a short-depth server comprised of two main sub-systems: the SC813MTS-350C 1U chassis an
1-2SUPERSERVER 5016I-M6F User's Manual1-2 Motherboard FeaturesAt the heart of the SuperServer 5016I-M6F lies the X8SI6-F, a single processor moth
1-3Chapter 1: IntroductionOther FeaturesOther onboard features that promote system health include onboard voltage moni-tors, a chassis intrusion heade
1-4SUPERSERVER 5016I-M6F User's ManualFigure 1-1. Intel 3420 Chipset: System Block Diagram Note: This is a general block diagram. Please see Chap
1-5Chapter 1: Introduction1-4 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131 U.S.A.Tel: +1 (40
1-6SUPERSERVER 5016I-M6F User's ManualNotes
Chapter 2: Server Installation2-1Chapter 2 Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get your SuperServer 5016I-
2-2SUPERSERVER 5016I-M6F User's Manual!!Warnings and Precautions!installation only in a Restricted Access Location (dedicated equipment rooms, se
Chapter 2: Server Installation2-3Rack Mounting ConsiderationsAmbient Operating TemperatureIf installed in a closed or multi-unit rack assembly, the am
Manual Revision 1.0 Release Date: November 12, 2009The information in this User’s Manual has been carefully reviewed and is believed to be accur
2-4SUPERSERVER 5016I-M6F User's Manual2-4 Installing the System into a RackThis section provides information on installing the SuperServer 5016I
Chapter 2: Server Installation2-5Installing the Rack RailsDetermine where you want to place the SuperServer 5016I-M6F in the rack (see Rack and Server
2-6SUPERSERVER 5016I-M6F User's ManualFigure 2-2. Installing the Server into a Rack (with optional front bezel shown)Installing the Server into
Chapter 2: Server Installation2-7Figure 2-3. Installing the Server into a Telco Rack (with optional front bezel shown)Installing the Server into a Te
2-8SUPERSERVER 5016I-M6F User's Manual2-5 Checking the Motherboard SetupAfter you install the 5016I-M6F in the rack, you will need to open the u
Chapter 2: Server Installation2-9Figure 2-4.Accessing the Inside of the SuperServer 5016I-M6F2-6 Checking the Drive Bay SetupNext, you should check t
2-10SUPERSERVER 5016I-M6F User's ManualAlso note that all power and data cables have been routed in such a way that 2. they do not block the airfl
Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are several LEDs on the control panel as well as others on the SAS/SATA driv
3-2SUPERSERVER 5016I-M6F User's Manual3-3 Control Panel LEDsThe control panel located on the front of the SC813MTS-350C chassis has fi ve LEDs. T
Chapter 3: System Interface3-3PowerIndicates power is being supplied to the system's power supply units. This LED should normally be illuminated
PrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the installation an
3-4SUPERSERVER 5016I-M6F User's ManualNotes
Chapter 4: System Safety4-1Chapter 4 System Safety4-1 Electrical Safety Precautions!Basic electrical safety precautions should be followed to protect
SUPERSERVER 5016I-M6F User's Manual4-24-2 General Safety PrecautionsFollow these rules to ensure general safety:Keep the area around the 5016I-M
Chapter 4: System Safety4-34-3 ESD PrecautionsElectrostatic Discharge (ESD) is generated by two objects with different electrical charges coming into
SUPERSERVER 5016I-M6F User's Manual4-44-4 Operating PrecautionsCare must be taken to assure that the chassis cover is in place when the 5016I-M6F
Chapter 5: Advanced Motherboard Setup5-1Chapter 5 Advanced Motherboard SetupThis chapter covers the steps required to install the X8SI6-F motherboard
5-2SUPERSERVER 5016I-M6F User's Manual5-2 Motherboard InstallationThis section explains the fi rst step of physically mounting the X8SI6-F into th
Chapter 5: Advanced Motherboard Setup5-3cables (with their locations noted) should be connected. (See the layout on page 5-9 for connector locations.)
5-4SUPERSERVER 5016I-M6F User's Manual5-4 I/O PortsThe I/O ports are color coded in conformance with the PC 99 specifi cation. See Figure 5-2 bel
Chapter 5: Advanced Motherboard Setup5-5Installing the LGA1156 Processor Press the load lever to release the load plate, which covers the CPU socket,
SUPERSERVER 5016I-M6F User's ManualivChapter 4: System SafetyYou should thoroughly familiarize yourself with this chapter for a general overview
5-6SUPERSERVER 5016I-M6F User's ManualAlign the CPU key that is the semi-circle cutouts against the socket keys. 4. Once aligned, carefully lower
Chapter 5: Advanced Motherboard Setup5-7Installing a Passive CPU HeatsinkDo not apply any thermal grease to the heatsink or the CPU die -- the re-1. q
5-8SUPERSERVER 5016I-M6F User's ManualRemoving the HeatsinkWarning: We do not recommend removing the CPU or the heatsink. How-ever, if you do nee
Chapter 5: Advanced Motherboard Setup5-95-6 Installing MemoryNote: Check the Supermicro web site for recommended memory modules.CAUTIONExercise extrem
5-10SUPERSERVER 5016I-M6F User's ManualTable 2 - DDR3 ECC Registered (RDIMM) Memory SupportRDIMM 1Gb (x8 DRAM) 2Gb (x8 DRAM)Single Rank Up to 6GB
Chapter 5: Advanced Motherboard Setup5-11Note: For ECC UDIMMs, only Slot 1 and/or Slot 2 may be populated per chan-nel.Slot 1, Channel ASlot 2, Channe
5-12SUPERSERVER 5016I-M6F User's ManualFigure 5-6. X8SI6-F Layout5-8 Motherboard DetailsR1312C135341JPW21JPW151+B1JBT1+J8J5Y2JS8JS7J24J13J14JWOLJ
Chapter 5: Advanced Motherboard Setup5-13Note: Jumpers and LEDs are listed on the next page.Headers & ConnectorsNumber Connector Description4 COM1
5-14SUPERSERVER 5016I-M6F User's ManualJumpers# Jumper Description Default43 JPUSB1 USB0/1 Wake-up Pins 1-2 (Enabled)48 JBT1 CMOS Clear (See Sect
Chapter 5: Advanced Motherboard Setup5-155-9 Connector Defi nitions ATX Power 24-pin ConnectorPin Defi nitionsPin# Defi nition Pin # Defi ni
vPrefaceNotes
5-16SUPERSERVER 5016I-M6F User's ManualHDD LEDThe HDD LED connection is located on pins 13 and 14 of JF1. This LED is used to display HDD activit
Chapter 5: Advanced Motherboard Setup5-17Fan HeadersThe X8SI6-F has fi ve fan headers, all of which are 4-pin fans. However, pins 1-3 of the fan header
5-18SUPERSERVER 5016I-M6F User's ManualLAN1/LAN2 (Ethernet Ports)Two Ethernet ports are located on the I/O backplane. These ports accept RJ45 typ
Chapter 5: Advanced Motherboard Setup5-19NC = No ConnectionPower Supply I2C ConnectorThe Power Supply (I2C) connector is located at SMB_PS1 and is use
5-20SUPERSERVER 5016I-M6F User's ManualWake-On-RingThe Wake-On-Ring header is des-ignated JWOR. This function allows your computer to wake up whe
Chapter 5: Advanced Motherboard Setup5-215-10 Jumper SettingsExplanation of JumpersTo modify the operation of the mother-board, jumpers can be used to
5-22SUPERSERVER 5016I-M6F User's ManualLAN1/LAN2 Enable/Disable Change the setting of jumper JPL1 or JPL2 to enable or disable the LAN1 and LAN2
Chapter 5: Advanced Motherboard Setup5-23SAS Enable/Disable Jumper Settings Jumper Settings Defi nition Pins 1-2 Enabled (Default)Pins 2-3 Disa
5-24SUPERSERVER 5016I-M6F User's ManualIPMI Heartbeat LEDAn IPMI Heartbeat LED is located at LE7. When LE7 blinks, IPMI is func-tioning properly.
Chapter 5: Advanced Motherboard Setup5-255-12 SAS, SATA and Floppy Drive ConnectionsSAS/SATA PortPin Defi nitionsPin # Defi nition 1 Gr
viSUPERSERVER 5016I-M6F User's ManualTable of ContentsChapter 1 Introduction1-1 Overview ...
5-26SUPERSERVER 5016I-M6F User's ManualNote: Click the icons showing a hand writing on the paper to view the readme fi les for each item. Click a
Chapter 5: Advanced Motherboard Setup5-27Supero Doctor III Interface Display Screen-I (Health Information)5-14 Confi guring Supero Doctor IIIThe Supero
5-28SUPERSERVER 5016I-M6F User's ManualNote: SD III Software Revision 1.0 can be downloaded from our Web site at: ftp://ftp.supermicro.com/utilit
Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform main-tena
6-2SUPERSERVER 5016I-M6F User's ManualFigure 6-2. Chassis Rear View6-2 Control PanelThe control panel (located on the front of the chassis) must
Chapter 6: Advanced Chassis Setup6-36-3 System FansFour 4-cm high-performance fans provide the cooling for the SuperServer 5016I-M6F. The chassis incl
6-4SUPERSERVER 5016I-M6F User's ManualFigure 6-4. Mounting a Drive in a CarrierUse caution when working around the SAS/SATA backplane. Do not tou
Chapter 6: Advanced Chassis Setup6-5Installing/Removing SAS/SATA DrivesTo remove a carrier, push the release button located beside the drive LEDs.1. S
6-6SUPERSERVER 5016I-M6F User's ManualDVD-ROM Drive InstallationThe top cover of the chassis must be opened to gain full access to the DVD-ROM dr
Chapter 6: Advanced Chassis Setup6-76-5 Power SupplyThe SuperServer 5016I-M6F has a single 350 watt power supply. This power supply has the capability
viiTable of ContentsInstalling the Server into a Telco Rack ...2-72-5 Checking the Motherboar
6-8SUPERSERVER 5016I-M6F User's ManualNotes
Chapter 7: BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the AMI BIOS Setup Utility for the X8SI6-F. The AMI ROM BIOS is stored in a Fl
7-2SUPERSERVER 5016I-M6F User's ManualHow to Start the Setup UtilityNormally, the only visible Power-On Self-Test (POST) routine is the memory te
Chapter 7: BIOS7-3System Overview: The following BIOS information will be displayed:System Time/System Date Use this option to change the system time
7-4SUPERSERVER 5016I-M6F User's Manual7-3 Advanced Setup Confi gurationsUse the arrow keys to select Boot Setup and hit <Enter> to access
Chapter 7: BIOS7-5Wait For 'F1' If ErrorThis forces the system to wait until the 'F1' key is pressed if an error occurs. The opti
7-6SUPERSERVER 5016I-M6F User's Manualting. Select Auto for the BIOS to automatically select the CPU multiplier setting for your system. The opti
Chapter 7: BIOS7-7Simultaneous Multi-Threading (Available when supported by the CPU)Set to Enabled to use the Hyper-Threading Technology, which will r
7-8SUPERSERVER 5016I-M6F User's ManualXAdvanced Chipset ControlThe items included in the Advanced Settings submenu are listed below.Memory Remap
Chapter 7: BIOS7-9SATA#1 Confi gurationIf Compatible is selected, it sets SATA#1 to legacy compatibility mode, while se-lecting Enhanced sets SATA#1 to
viiiSUPERSERVER 5016I-M6F User's Manual5-8 Motherboard Details ...
7-10SUPERSERVER 5016I-M6F User's ManualBlock (Multi-Sector Transfer)Block Mode boosts the IDE drive performance by increasing the amount of data
Chapter 7: BIOS7-11Select MWDMA2 to allow the BIOS to use Multi-Word DMA mode 2. It has a data transfer rate of 16.6 MBs. Select UDMA0 to allow the BI
7-12SUPERSERVER 5016I-M6F User's ManualPCI Latency TimerThis feature sets the latency Timer of each PCI device installed on a PCI bus. Select 64
Chapter 7: BIOS7-13for Serial Port1 are Disabled, 3F8/IRQ4, 2E8/IRQ3. The options for Serial Port2 are Disabled, 2F8/IRQ3, and 2E8/IRQ3.Onboard Floppy
7-14SUPERSERVER 5016I-M6F User's ManualVT-UTF8 Combo Key SupportA terminal keyboard defi nition that provides a way to send commands from a remote
Chapter 7: BIOS7-15Low – This level is considered as the ‘normal’ operating state. The CPU temperature is well below the CPU ‘Temperature Tolerance’.
7-16SUPERSERVER 5016I-M6F User's ManualSupermicro has leveraged this feature by assigning a temperature status to certain thermal conditions in t
Chapter 7: BIOS7-17tion embedded in the CPU. The High Performance Event Timer is used to replace the 8254 Programmable Interval Timer. The options are
7-18SUPERSERVER 5016I-M6F User's ManualClear BMC System Event LogThis feature is used to clear the System Event Log. Caution: Any cleared informa
Chapter 7: BIOS7-19after an operating system failure is detected. The options are [5 Min], [1 Min], [30 Sec], and [10 Sec].XEvent Log Confi gurationVie
Table of ContentsixRear UID LED ...5-245-12 SAS, SATA and Flop
7-20SUPERSERVER 5016I-M6F User's Manual7-4 Security SettingsThe AMI BIOS provides a Supervisor and a User password. If you use both pass-words, t
Chapter 7: BIOS7-21Use this feature to confi gure Boot Settings:XBoot Device PriorityThis feature allows the user to specify the sequence of priority f
7-22SUPERSERVER 5016I-M6F User's ManualXHard Disk DrivesThis feature allows the user to specify the sequence of priority from the available Hard
Chapter 7: BIOS7-23Save Changes and ExitWhen you have completed the system confi guration changes, select this option to leave the BIOS Setup Utility a
7-24SUPERSERVER 5016I-M6F User's ManualNotes
Appendix A: POST Error Beep CodesA-1Appendix A POST Error Beep CodesThis section lists POST (Power On Self Test) error beep codes for the AMI BIOS. PO
A-2SUPERSERVER 5016I-M6F User's ManualNotes
Appendix B: Installing WindowsB-1Appendix B Installing Windows After all hardware components have been installed, you must fi rst confi gure Intel South
B-2SUPERSERVER 5016I-M6F User's ManualB-2 Installing Windows to a Non-RAID SystemInsert Microsoft's Windows OS Setup CD in the CD-ROM drive
C-1Appendix C: System Specifi cationsAppendix C System Specifi cationsProcessors One Intel® Xeon® 3400 Series and L3426 processors in an LGA1156