1-2SUPERSERVER 7046T-H6R/7046T-H6RF User's Manual1-2 Serverboard FeaturesThe SuperServer 7046T-H6R/7046T-H6RF is built upon the X8DTH-6/X8DTH-6F,
B-2SUPERSERVER 7046T-H6R/7046T-H6RF User's ManualServerboard X8DTH-6/X8DTH-6F (Extended ATX form factor) Dimensions: 12 x 13 in (305
B-3Appendix B: System Specifi cationsNotes
B-4SUPERSERVER 7046T-H6R/7046T-H6RF User's Manual(continued from front)The products sold by Supermicro are not intended for and will not be used
1-3Chapter 1: IntroductionGraphics ControllerThe X8DTH-6/X8DTH-6F features an integrated Matrox G200eW graphics chip, which includes 16 MB of DDR2 mem
1-4SUPERSERVER 7046T-H6R/7046T-H6RF User's ManualFigure 1-1. Intel 5520/ICH10R Chipset: System Block DiagramNote: This is a general block diagra
1-5Chapter 1: Introduction1-4 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131 U.S.A.Tel: +1 (40
1-6SUPERSERVER 7046T-H6R/7046T-H6RF User's ManualNotes
Chapter 2: Server Installation2-1Chapter 2 Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get your SuperServer 7046T-
2-2SUPERSERVER 7046T-H6R/7046T-H6RF User's Manual!!Warnings and Precautions!Choosing a Setup LocationLeave enough clearance in front of the rack
Chapter 2: Server Installation2-3Allow the hot plug SATA drives and power supply modules to cool before touch-• ing them.Always keep the rack's f
2-4SUPERSERVER 7046T-H6R/7046T-H6RF User's Manual2-4 Installing the System into a RackThis section provides information on installing the system
Chapter 2: Server Installation2-5Installing the Chassis RailsYou will need to remove the top cover and the feet to add rack rails to the chassis. Firs
Manual Revision 1.0 Release Date: November 3, 2009The information in this User’s Manual has been carefully reviewed and is believed to be accura
2-6SUPERSERVER 7046T-H6R/7046T-H6RF User's ManualInstalling the Rack RailsDetermine where you want to place the SuperServer 7046T-H6R/7046T-H6RF
Chapter 2: Server Installation2-7Figure 2-4. Installing the Server into a RackInstalling the Server into the RackYou should now have rails attached t
2-8SUPERSERVER 7046T-H6R/7046T-H6RF User's Manual2-5 Checking the Serverboard SetupAfter setting up the the system, you will need to open the un
Chapter 2: Server Installation2-92-6 Checking the Drive Bay SetupNext, you should check to make sure the peripheral drives and then SATA drives and b
2-10SUPERSERVER 7046T-H6R/7046T-H6RF User's ManualFigure 2-5. Accessing the Inside of the System (Rack Confi guration shown)
Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThe control panel on the 7046T-H6R/7046T-H6RF has several LEDs and two but-tons. T
3-2SUPERSERVER 7046T-H6R/7046T-H6RF User's Manual3-3 Control Panel LEDsThe control panel located on the front of the SC745 chassis has six LEDs
Chapter 3: System Interface3-3Overheat/Fan FailWhen this LED fl ashes, it indicates a fan failure. When on continuously it indicates an overheat condit
3-4SUPERSERVER 7046T-H6R/7046T-H6RF User's ManualNotes
Chapter 4: System Safety4-1Chapter 4 System Safety4-1 Electrical Safety Precautions!Basic electrical safety precautions should be followed to protect
iiiPrefacePrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the insta
SUPERSERVER 7046T-H6R/7046T-H6RF User's Manual4-2!This product may be connected to an IT power system. In all cases, make sure • that the unit is
Chapter 4: System Safety4-3Remove any jewelry or metal objects from your body, which are excellent metal • conductors that can create short circuits a
SUPERSERVER 7046T-H6R/7046T-H6RF User's Manual4-44-4 Operating PrecautionsCare must be taken to assure that the chassis cover is in place when th
Chapter 5: Advanced Serverboard Setup5-1Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to install the X8DTH-6/X8DTH-6F ser
5-2SUPERSERVER 7046T-H6R/7046T-H6RF User's ManualUnpackingThe serverboard is shipped in antistatic packaging to avoid electrical static dis-charg
Chapter 5: Advanced Serverboard Setup5-35-3 Connecting CablesNow that the serverboard is installed, the next step is to connect the cables to the boar
5-4SUPERSERVER 7046T-H6R/7046T-H6RF User's Manual5-4 I/O PortsThe I/O ports are color coded in conformance with the PC 99 specifi cation. See Fig
Chapter 5: Advanced Serverboard Setup5-5!Press the socket clip to release 1. the load plate, which covers the CPU socket, from its locked posi-tion.Ge
5-6SUPERSERVER 7046T-H6R/7046T-H6RF User's ManualAfter removing the plastic cap, use 1. your thumb and the index fi nger to hold the CPU at the no
Chapter 5: Advanced Serverboard Setup5-7Remove power from the system 1. and unplug the AC power cord from the power supply.Do not apply any thermal gr
SUPERSERVER 7046T-H6R/7046T-H6RF User's ManualivChapter 5: Advanced Serverboard SetupChapter 5 provides detailed information on the X8DTH-6/X8DT
5-8SUPERSERVER 7046T-H6R/7046T-H6RF User's ManualMemory SupportThe X8DTH-6/X8DTH-6F supports up to 96 GB of DDR3-1333/1066/800 registered ECC SDR
Chapter 5: Advanced Serverboard Setup5-9Populating DIMMsNote: Memory speed support depends on the CPU used on the motherboard.DIMM Module Population C
5-10SUPERSERVER 7046T-H6R/7046T-H6RF User's Manual5-7 Installing PCI Expansion CardsThe 7046T-H6R/7046T-H6RF can accommodate standard size add-o
Chapter 5: Advanced Serverboard Setup5-11Figure 5-4. X8DTH-6/X8DTH-6F Layout(not drawn to scale)5-8 Serverboard DetailsJ*X8DTH-6FRev. 1.02Intel5520(IO
5-12SUPERSERVER 7046T-H6R/7046T-H6RF User's ManualX8DTH-6F/X8DTH-6 Quick ReferenceJumper Description Default SettingJBT1 CMOS Clear Open (Normal)
Chapter 5: Advanced Serverboard Setup5-13Reset ButtonThe Reset Button connection is located on pins 3 and 4 of JF1 and attaches to the reset switch on
5-14SUPERSERVER 7046T-H6R/7046T-H6RF User's ManualOverheat/Fan Fail LED (OH)Connect an LED to the OH connection on pins 7 and 8 of JF1 to provide
Chapter 5: Advanced Serverboard Setup5-15Fan HeadersThere are eight fan headers on the serverboard, all of which are 4-pin fans. Pins 1-3 of the fan h
5-16SUPERSERVER 7046T-H6R/7046T-H6RF User's ManualChassis IntrusionThe Chassis Intrusion header is des-ignated JL1. Attach an appropriate cable f
Chapter 5: Advanced Serverboard Setup5-17Universal Serial Bus (USB)There are two Universal Serial Bus ports located on the I/O panel and four addition
NotesPrefacev
5-18SUPERSERVER 7046T-H6R/7046T-H6RF User's Manual5-10 Jumper SettingsExplanation of JumpersTo modify the operation of the serverboard, jumpers c
Chapter 5: Advanced Serverboard Setup5-19LAN1/2 Enable/Disable Change the setting of jumper JPL1 to enable or disable the LAN1/LAN2 Eth-ernets port on
5-20SUPERSERVER 7046T-H6R/7046T-H6RF User's Manual5-11 Onboard IndicatorsLAN1/2 LEDsThe Ethernet ports (located beside the VGA port) have two LED
Chapter 5: Advanced Serverboard Setup5-21SAS Error LEDA SAS Error LED is located at DP7. When DP7 is on, an error has oc-curred with the SAS connectio
5-22SUPERSERVER 7046T-H6R/7046T-H6RF User's Manual5-13 Installing SoftwareAfter the hardware has been installed, you should fi rst install the ope
Chapter 5: Advanced Serverboard Setup5-23Supero Doctor IIIThe Supero Doctor III program is a web-based management tool that supports remote management
5-24SUPERSERVER 7046T-H6R/7046T-H6RF User's ManualNote: SD III Software Revision 1.0 can be downloaded from our Web Site at: ftp://ftp.supermicro
Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform simple ma
6-2SUPERSERVER 7046T-H6R/7046T-H6RF User's ManualFigure 6-1. Chassis Front ViewSystem ResetMain Power 5.25" Drive Bays (2)USB Ports8 SATA D
Chapter 6: Advanced Chassis Setup6-36-2 Front Control PanelThe front control panel must be connected to the JF1 connector on the serverboard to provi
viTable of ContentsChapter 1 Introduction1-1 Overview ...
6-4SUPERSERVER 7046T-H6R/7046T-H6RF User's Manual6-3 System FansThree 8-cm chassis cooling fans (located in the center of the chassis) provide co
Chapter 6: Advanced Chassis Setup6-5Figure 6-4. Removing the Air ShroudFigure 6-3. Removing a Chassis Fan
6-6SUPERSERVER 7046T-H6R/7046T-H6RF User's ManualInstalling/Removing SAS/SATA DrivesTo remove a carrier, fi rst open the front bezel.1. Push the r
Chapter 6: Advanced Chassis Setup6-7Figure 6-6. Mounting a SATA Drive in a Carrier!Important! Use extreme caution when working around the SAS backpla
6-8SUPERSERVER 7046T-H6R/7046T-H6RF User's ManualInstalling Components in the 5.25" Drive BaysThe 7046T-H6R/7046T-H6RF has two 5.25" dr
Chapter 6: Advanced Chassis Setup6-9Storage ModuleIf the 7046T-H6R/7046T-H6RF is to be used in a rack confi guration, you must turn the storage module
6-10SUPERSERVER 7046T-H6R/7046T-H6RF User's ManualAdding Drives to the Storage ModuleThe storage module includes three full sized drive bays and
Chapter 6: Advanced Chassis Setup6-11Figure 6-8. Adding Hard Drive Rails to the Storage Rack6-5 Power SupplyThe SuperServer 7046T-H6R/7046T-H6RF has
6-12SUPERSERVER 7046T-H6R/7046T-H6RF User's ManualInstalling a New Power SupplyReplace the failed module with another power supply module (must b
Chapter 7: BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the AMI BIOS Setup Utility for the X8DTH-6/X8DTH-6F. The AMI ROM BIOS is store
vii2-6 Checking the Drive Bay Setup ... 2-9Chapter 3 System Interface3-1 Overvie
7-2SUPERSERVER 7046T-H6R/7046T-H6RF User's ManualStarting the Setup UtilityNormally, the only visible Power-On Self-Test (POST) routine is the me
Chapter 7: BIOS7-3Supermicro X8DTHVersion• : This item displays the BIOS revision used in your system.Build Date• : This item displays the date when
7-4SUPERSERVER 7046T-H6R/7046T-H6RF User's Manual7-3 Advanced Setup Confi gurationsUse the arrow keys to select Advanced Setup and press <Ente
Chapter 7: BIOS7-5Wait For 'F1' If ErrorThis forces the system to wait until the <F1> key is pressed if an error occurs. The options a
7-6SUPERSERVER 7046T-H6R/7046T-H6RF User's ManualCPU RatioIf set to Manual, this option allows the user to set the ratio between the CPU Core Clo
Chapter 7: BIOS7-7MPS and ACPI MADT OrderingThis feature allows the user to decide how to order the Multiple APIC Description Table (MADT). Select Mod
7-8SUPERSERVER 7046T-H6R/7046T-H6RF User's ManualC1E SupportSelect Enabled to use the feature of Enhanced Halt State. C1E signifi cantly reduces t
Chapter 7: BIOS7-9XAdvanced Chipset ControlXQPI & IMC Confi gurationQPI Links SpeedUse this item to select QPI data transfer speeds and enable/disa
7-10SUPERSERVER 7046T-H6R/7046T-H6RF User's ManualThrottling - Closed Loop/Throttling - Open LoopThrottling improves reliability and reduces powe
Chapter 7: BIOS7-11Intel VT-dSelect Enabled to enable Intel's Virtualization Technology support for Direct I/O VT-d by reporting the I/O device a
viiiX8DTH-6F/X8DTH-6 Quick Reference ... 5-125-9 Connector Defi nitions ...
7-12SUPERSERVER 7046T-H6R/7046T-H6RF User's ManualXIDE/SATA Confi gurationWhen this submenu is selected, the AMI BIOS automatically detects the pr
Chapter 7: BIOS7-13If not, contact your manufacturer or install an ATA/133 IDE controller card that supports 48-bit LBA mode. The options are Disabled
7-14SUPERSERVER 7046T-H6R/7046T-H6RF User's ManualSelect MWDMA1 to allow the BIOS to use Multi Word DMA mode 1. It has a data transfer rate of 13
Chapter 7: BIOS7-15PCI Latency TimerThis feature sets the latency timer of each PCI device installed on a PCI bus. Select 64 to set the PCI latency to
7-16SUPERSERVER 7046T-H6R/7046T-H6RF User's Manualdress and IRQ 4 for the interrupt address. The options are Disabled, 3F8/IRQ4, 3E8/IRQ4, 2E8/IR
Chapter 7: BIOS7-17Sredir Memory Display DelayThis feature defi nes the length of time in seconds to display memory information. The options are No De
7-18SUPERSERVER 7046T-H6R/7046T-H6RF User's ManualMedium – The processor is running warmer. This is a ‘precautionary’ level and generally means t
Chapter 7: BIOS7-19system cooling. Select "Full Speed/FS" to allow the onboard fans to run at full speed for maximum cooling. The FS setting
7-20SUPERSERVER 7046T-H6R/7046T-H6RF User's ManualHeadless ModeThis feature is used to enable system to function without a keyboard, monitor and/
Chapter 7: BIOS7-21TPM Owner StatusThis item displays the status of TPM Ownership.XIPMI Confi gurationIntelligent Platform Management Interface (IPMI)
Chapter 1 Introduction1-1 OverviewThe SuperServer 7046T-H6R/7046T-H6RF is a high-end server comprised of two main subsystems: the SC745TQ-R800B server
7-22SUPERSERVER 7046T-H6R/7046T-H6RF User's ManualClear BMC System Event LogSelect OK and press the <Enter> key to clear the BMC system log
Chapter 7: BIOS7-23BMC Watch Dog Timer ActionThis feature allows the BMC to reset or power down the system if the operating system hangs or crashes. T
7-24SUPERSERVER 7046T-H6R/7046T-H6RF User's ManualSupervisor Password This item indicates if a Supervisor password has been entered for the syste
Chapter 7: BIOS7-25No Access: This feature prevents User from accessing the Setup Utility.• Change User PasswordSelect this feature and press <Ente
7-26SUPERSERVER 7046T-H6R/7046T-H6RF User's ManualXBoot Device PriorityThis feature allows the user to specify the sequence of priority for the B
Chapter 7: BIOS7-277-6 Exit OptionsSelect the Exit tab from the AMI BIOS Setup Utility screen to enter the Exit BIOS Setup screen.Save Changes and Exi
7-28SUPERSERVER 7046T-H6R/7046T-H6RF User's ManualLoad Fail-Safe DefaultsTo set this feature, select Load Fail-Safe Defaults from the Exit menu a
A-1Appendix A: BIOS Error Beep CodesAppendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the
A-2SUPERSERVER 7046T-H6R/7046T-H6RF User's ManualNotes
B-1Appendix B: System Specifi cationsAppendix B System Specifi cationsProcessors Single or dual Intel® Xeon® 5500 LGA1366 processors (both CPUs m