D-7
Appendix D: SAS2-847EL Backplane Specications
General Jumper Settings
Jumper Jumper Settings Note
PRI_MODE1 and 2 Pins 2-3
Factory Setting
Do not change
SEC_MODE1 and 2 Pins 2-3
Factory Setting
Do not change
MDI01 and 02 No jumper required SMC internal use only
UART_P1 No jumper required Primary UART connector
UART_S1 No jumper required
Secondary UART connector
(Not present on SAS2-847E2)
JP1 No jumper required Buzzer connector
BUZZER_ENB1
Open: Disable
Closed: Enable
Buzzer enable*
ACTLED1
Open: Disable
Closed: Enable
For manufacturing use only
FAN_MONITOR_DIS-
ABLE
Open: Enable
Closed: Disable
Fan monitor settings
FANFAIL_LED_DIS-
ABLE
Open: Enable
Closed: Disable
Disables the fan failure LED
EXPDBG1 N/A For manufacturing use only.
EXPDBG2 N/A For manufacturing use only.
*The buzzer sound indicates that a condition requiring immediate attention has
occurred.
The buzzer alarm is triggered by the following conditions:
Hard drive failure1.
Fan failure2.
System temperature over 45º Celsius.3.