Supermicro AOC-USASLP-L8I Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Řadiče RAID Supermicro AOC-USASLP-L8I. Supermicro AOC-USASLP-L8I RAID controller Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 104
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků

Shrnutí obsahu

Strany 1 - User’s Manual

AOC-USASLP-L8i Add-on CardUser’s ManualRevison 1.0

Strany 2 - REPRODUCTIVE HARM

AOC-USASLP-L8i Add-on Card User’s Manual1-2Notes

Strany 3 - Table of Contents

AOC-USASLP-L8i Add-on Card User’s Manual9-12When a disk drive is added to an IM, IME, or IS volume, its entire storage capacity may or may not be used

Strany 4

9-13Chapter 9: Using the CFGGEN IR Configuration UtilityDISABLEIR Command (EFI Version Only)The DISABLEIR command, which is currently supported only i

Strany 5

AOC-USASLP-L8i Add-on Card User’s Manual9-14LIST Command (EFI Version Only)The LIST command, which is currently supported only in the EFI version of C

Strany 6

DisclaimerThe products sold by Supermicro are not intended for and will not be used in life support systems, medical equipment, nuclear facilities or

Strany 7 - An Important Note to Users

AOC-USASLP-L8i Add-on Card User’s Manual

Strany 8 - Contacting SuperMicro

2-1Chapter 2Connectors, Jumpers and Indicators2-1 Front Connectors and Pin DefinitionsConnectors are used to attach the add-on card to the system’s ma

Strany 9 - Safety Guidelines

AOC-USASLP-L8i Add-on Card User’s Manual2-22-2 Front Jumper Locations and Pin DefinitionsTo modify the operation of the backplane, jumpers can be used

Strany 10

2-3Chapter 2: Connectors, Jumpers and Indicators2-3 RAID Minimum Drive RequirementsUse Table 2-3 to determine the minimum number of hard drives needed

Strany 11 - Chapter 2

AOC-USASLP-L8i Add-on Card User’s Manual2-4Notes

Strany 12

3-1Chapter 3RAID Modes, Firmware and DriversTo change RAID modes from the AOC-USASLP-L8i add-on card’s default IT Mode, you need to flash your system’

Strany 13

AOC-USASLP-L8i Add-on Card User’s Manual3-23-2 Getting Firmware DownloadsFirmware for RAID modes can only be obtained through contacting SuperMicro Te

Strany 14

3-3Chapter 3: RAID Modes, Firmware and Drivers3-5 Activating RAID Modes in OPROM BIOSRAID modes can be activated by pressing keyboard keys in the OPRO

Strany 15 - Chapter 3

AOC-USASLP-L8i Add-on Card User’s Manual3-4Notes

Strany 16 - 3-3 Flashing Firmware

4-1Chapter 4MegaRAID BIOS Configuration UtilityThe LSI™ MegaRAID® BIOS Configuration Utility (CU) is used to configure disk arrays and virtual drives

Strany 17

AOC-USASLP-L8i Add-on Card User’s ManualiiThe information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor

Strany 18

AOC-USASLP-L8i Add-on Card User’s Manual4-2The number of physical drives in a specific array determines the possible RAID levels that you can implemen

Strany 19 - Chapter 4

4-3Chapter 4: MegaRAID BIOS Configuration UtilityFollow the steps below to create a virtual drive using EASY CONFIGURATION:1. Select CONFIGURATION J E

Strany 20 - Starting the MegaRAID BIOS CU

AOC-USASLP-L8i Add-on Card User’s Manual4-44. Highlight RAID and press ENTER.The available RAID levels for the current virtual drive are displayed.5.

Strany 21

4-5Chapter 4: MegaRAID BIOS Configuration UtilityUsing New Configuration and View/Add ConfigurationWhen you select the NEW CONFIGURATION menu option,

Strany 22 - ANAGEMENT menu

AOC-USASLP-L8i Add-on Card User’s Manual4-68. Highlight RAID and press ENTER.A list of the available RAID levels for the current virtual drive appears

Strany 23

4-7Chapter 4: MegaRAID BIOS Configuration Utility3. Select an un-configured drive or READY drive from the list, and press ENTER.4. When the PHYSICAL D

Strany 24

AOC-USASLP-L8i Add-on Card User’s Manual4-85. After the initialization is complete, press ESC to return to previous menus.If you press ESC while initi

Strany 25 - Initializing Virtual Drives

4-9Chapter 4: MegaRAID BIOS Configuration Utility3. Select INITIALIZE from the submenu and press ENTER.4. Select YES at the prompt and press ENTER.The

Strany 26 - Second Initialization Method

AOC-USASLP-L8i Add-on Card User’s Manual4-104-4 Rebuilding a DriveThe MegaRAID BIOS CU enables you to rebuild a drive of a redundant array if the arra

Strany 27 - Policies

4-11Chapter 4: MegaRAID BIOS Configuration Utility4-5 Hot Plug SupportMegaRAID BIOS CU supports hot plugging of disk drives. When you insert or remove

Strany 28 - 4-4 Rebuilding a Drive

iiiTable of ContentsChapter 1 Safety Guidelines ...1-11-1 ESD Safety Guidelines...

Strany 29 - 4-6 Checking Data Consistency

AOC-USASLP-L8i Add-on Card User’s Manual4-12Checking Data Consistency1. On the MANAGEMENT menu select CHECK CONSISTENCY and press ENTER.A list of conf

Strany 30

4-13Chapter 4: MegaRAID BIOS Configuration UtilityViewing and Changing Adapter PropertiesTo view or change adapter properties, follow these steps:1. O

Strany 31

AOC-USASLP-L8i Add-on Card User’s Manual4-14NotesViewing Physical Drive PropertiesTo view physical drive properties, follow these steps:1. On the MANA

Strany 32 - 4-10 Deleting a Virtual Drive

4-15Chapter 4: MegaRAID BIOS Configuration UtilityTo delete a specified virtual drive, follow these steps:1. Select OBJECTS J VIRTUAL DRIVE.2. Highlig

Strany 33 - ES to confirm

AOC-USASLP-L8i Add-on Card User’s Manual4-16Notes

Strany 34

5-1Chapter 5MegaRAID Overview and InstallationThis chapter explains provides and overview of MegaRAID Storage Manager software, and instructions on ho

Strany 35 - Chapter 5

AOC-USASLP-L8i Add-on Card User’s Manual5-25-2 Hardware and Software RequirementsThe hardware requirements for MegaRAID Storage Manager software are a

Strany 36 - 5-3 Installing for Windows

5-3Chapter 5: MegaRAID Overview and Installation4. Enter your user name and organization name, and in the bottom part of the screen, select an install

Strany 37

AOC-USASLP-L8i Add-on Card User’s Manual5-46. Select one of the Setup options. The options are fully explained in the screen text.• Select COMPLETE if

Strany 38

5-5Chapter 5: MegaRAID Overview and InstallationFor example, to connect to a remote framework on server 192.168.0.10, add the IP address to the end of

Strany 39 - 5-4 Installing for Linux

AOC-USASLP-L8i Add-on Card User’s ManualivViewing and Changing Virtual Drive Properties ...4-13Viewing Physical Drive

Strany 40

AOC-USASLP-L8i Add-on Card User’s Manual5-6• The version is already installed.This message indicates that the version of MegaRAID Storage Manager soft

Strany 41 - MegaRAID Window and Menus

6-1Chapter 6MegaRAID Window and MenusThe MegaRAID Storage Manager software is a configuration and monitoring utility used with the Embedded MegaRAID S

Strany 42 - PDATE. If you check the

AOC-USASLP-L8i Add-on Card User’s Manual6-2If the circle in the server icon is yellow instead of green, it means that the server is running in a degra

Strany 43

6-3Chapter 6: MegaRAID Window and Menus3. Select an access mode from the drop-down menu.• Select FULL ACCESS if you need to both view the current conf

Strany 44 - Physical/Logical View Panel

AOC-USASLP-L8i Add-on Card User’s Manual6-46-2 MegaRAID Storage Manager WindowThis section describes the MEGARAID STORAGE MANAGER window (Figure 6-3).

Strany 45 - Menu Bar

6-5Chapter 6: MegaRAID Window and MenusThe following icons in the left panel represent the controllers, disk drives, and other devices:•System• Contro

Strany 46

AOC-USASLP-L8i Add-on Card User’s Manual6-6File MenuThe FILE menu has an EXIT option for exiting from the MEGARAID STORAGE MANAGER software. It also h

Strany 47

6-7Chapter 6: MegaRAID Window and MenusTo open the MegaRAID Storage Manager Configuration Wizard, select a controller in the left panel of the MEGARAI

Strany 48 - Using Auto Configuration

AOC-USASLP-L8i Add-on Card User’s Manual6-8The menu lists three configuration modes:• Auto Configuration automatically creates an optimal configuratio

Strany 49 - ONFIGURATION screen:

6-9Chapter 6: MegaRAID Window and MenusFollow these steps to create a new storage configuration in Auto Configuration mode:1. Select a redundancy opti

Strany 50 - Using Guided Configuration

v6-7 Deleting a Virtual Disk ...6-206-8 Saving a Storage Configuration to Disk...

Strany 51 - UIDED CONFIGURATION screen:

AOC-USASLP-L8i Add-on Card User’s Manual6-103. (Optional) Click MODIFY if you want to switch to Manual Configuration mode so you can modify the sugges

Strany 52 - INISH. If

6-11Chapter 6: MegaRAID Window and MenusFollow these steps to create a new storage configuration in Guided Configuration mode:1. Select a redundancy o

Strany 53 - EMOVE arrow button

AOC-USASLP-L8i Add-on Card User’s Manual6-124. Click NEXT to continue to the next screen (see Figure 6-7).5. Change the default volume parameters in t

Strany 54

6-13Chapter 6: MegaRAID Window and MenusUsing Manual Configuration: RAID 0Follow these steps to create a RAID 0 storage configuration using the Manual

Strany 55

AOC-USASLP-L8i Add-on Card User’s Manual6-143. Click NEXT. The DEFINING A VIRTUAL DISK screen of the Configuration Wizard appears, as shown in Figure

Strany 56

6-15Chapter 6: MegaRAID Window and Menus9. Click NEXT to continue with the next configuration step. The VIRTUAL DISK SUMMARY screen appears.10. Review

Strany 57

AOC-USASLP-L8i Add-on Card User’s Manual6-169. Click NEXT to continue with the next configuration step.The VIRTUAL DISK SUMMARY screen appears.10. Rev

Strany 58 - ITH AFFINITY)

6-17Chapter 6: MegaRAID Window and Menus9. Click NEXT to continue with the next configuration step. The VIRTUAL DISK SUMMARY screen appears.10. Review

Strany 59

AOC-USASLP-L8i Add-on Card User’s Manual6-186-4 Adding or Deleting a Hotspare DisksHotspares are disk drives that are available to automatically repla

Strany 60 - 6-7 Deleting a Virtual Disk

6-19Chapter 6: MegaRAID Window and MenusMake sure the capacity of the hotspare drive is equal to or larger than the capacity of the disks in the array

Strany 61

AOC-USASLP-L8i Add-on Card User’s Manualvi8-4 Integrated Striping Firmware ... 8-3Metadata Sup

Strany 62

AOC-USASLP-L8i Add-on Card User’s Manual6-20Each task rate can be set from 0 to 100. The higher the number, the faster the activity will run in the ba

Strany 63 - Mirroring Enhanced

6-21Chapter 6: MegaRAID Window and Menus6-8 Saving a Storage Configuration to DiskYou can save an existing controller configuration to a file so you c

Strany 64 - 7-3 IM/IME Description

AOC-USASLP-L8i Add-on Card User’s Manual6-226-10 Adding a Saved Storage ConfigurationWhen you replace a controller, or when you want to duplicate an e

Strany 65 - Logical View Physical View

7-1Chapter 7Integrated Mirroring and Integrated Mirroring EnhancedThis chapter provides an overview of the Integrated Mirroring (IM) and Integrated Mi

Strany 66 - Hot Swapping

AOC-USASLP-L8i Add-on Card User’s Manual7-27-2 IM and IME FeaturesIM and IME support the following features:• Configurations of one or two IM or IME v

Strany 67 - NVSRAM Usage

7-3Chapter 7: Integrated Mirroring and Integrated Mirroring EnhancedThe advantage of an IM/IME volume is that there is always a second, mirrored copy

Strany 68 - 7-5 Fusion-MPT Support

AOC-USASLP-L8i Add-on Card User’s Manual7-4The BIOS-based configuration utility enables you to create IM and IME volumes during initial setup and to r

Strany 69 - Creating an IM Volume

7-5Chapter 7: Integrated Mirroring and Integrated Mirroring EnhancedFollowing a hot swap event, the firmware readies the new physical disk by spinning

Strany 70

AOC-USASLP-L8i Add-on Card User’s Manual7-67-5 Fusion-MPT SupportThe BIOS uses the LSI Fusion-MPT® interface to communicate to the SAS controller and

Strany 71

7-7Chapter 7: Integrated Mirroring and Integrated Mirroring Enhanced• An IM volume must have two drives. An IME volume can have three to ten drives. I

Strany 72

iPrefaceAbout this ManualThis manual is written for system integrators, PC technicians and knowledgeable PC users who intend to integrate SuperMicro&a

Strany 73 - Creating an IME Volume

AOC-USASLP-L8i Add-on Card User’s Manual7-82. Press ENTER to go to the ADAPTER PROPERTIES screen, as shown in Figure 7-5 below:Figure 7-5. Adapter Pro

Strany 74 - 7-8 Managing Hot Spares

7-9Chapter 7: Integrated Mirroring and Integrated Mirroring Enhanced3. On the ADAPTER PROPERTIES screen, use the arrow keys to select RAID PROPERTIES

Strany 75 - 7-9 Other Configuration Tasks

AOC-USASLP-L8i Add-on Card User’s Manual7-104. In the SELECT NEW ARRAY TYPE screen (Figure 7-6), select CREATE IM VOLUME.The CREATE NEW ARRAY screen a

Strany 76 - Deleting an Array

7-11Chapter 7: Integrated Mirroring and Integrated Mirroring Enhanced8. When the volume has been fully configured, press C and then SAVE CHANGES. Then

Strany 77 - Selecting a Boot Disk

AOC-USASLP-L8i Add-on Card User’s Manual7-123. On the ADAPTER PROPERTIES screen, use the arrow keys to select RAID PROPERTIES and press ENTER.4. Conti

Strany 78

7-13Chapter 7: Integrated Mirroring and Integrated Mirroring EnhancedIf SATA disks are used for the IM/IME volume(s), the hot spare disk must also be

Strany 79 - Integrated Striping

AOC-USASLP-L8i Add-on Card User’s Manual7-14Follow these steps to force the synchronization of a selected array:1. Select SYNCHRONIZE ARRAY on the MAN

Strany 80 - Controller

7-15Chapter 7: Integrated Mirroring and Integrated Mirroring EnhancedLocating Drives in a VolumeYou can use the SAS BIOS CU to locate and identify a s

Strany 81 - 8-6 IS Configuration Overview

AOC-USASLP-L8i Add-on Card User’s Manual7-16Notes

Strany 82 - 8-7 Creating IS Volumes

8-1Chapter 8Integrated StripingThis chapter provides an overview of the LSI Integrated Striping™ (IS) feature and explains how to create Integrated St

Strany 83

AOC-USASLP-L8i Add-on Card User’s ManualiiContacting SuperMicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131 U.S.A.Te

Strany 84

AOC-USASLP-L8i Add-on Card User’s Manual8-2• SES status LED support for drives used in IS volumes8-3 IS DescriptionThe IS feature writes data across m

Strany 85 - 8-9 Other Configuration Tasks

8-3Chapter 8: Integrated Striping8-4 Integrated Striping FirmwareThis section describes features of the Integrated RAID firmware.Metadata SupportThe f

Strany 86 - Locating a Disk in a Volume

AOC-USASLP-L8i Add-on Card User’s Manual8-4The supported stripe size is 64 kilobytes. Refer to Section 8-2: "IS Features" on page 8-1 for mo

Strany 87

8-5Chapter 8: Integrated StripingCreating IS Volumes1. On the ADAPTER LIST screen of the SAS BIOS CU, use the arrow keys to select a SAS adapter.2. Pr

Strany 88

AOC-USASLP-L8i Add-on Card User’s Manual8-64. When you are prompted to select a volume type, select CREATE IS VOLUME.The CREATE NEW ARRAY screen (Figu

Strany 89 - Chapter 9

8-7Chapter 8: Integrated Striping8-8 Creating a Second IS VolumeSAS controllers allow you to configure two IS volumes, or an IS volume and an IM/IME v

Strany 90 - 9-3 CFGGEN Commands

AOC-USASLP-L8i Add-on Card User’s Manual8-8Follow these steps to activate a selected array.1. Select ACTIVATE ARRAY on the MANAGE ARRAY screen.2. Pres

Strany 91 - CREATE Command

8-9Chapter 8: Integrated StripingSelecting a Boot DiskYou can select a boot disk in the SAS TOPOLOGY screen. This disk is then moved to scan ID 0 on t

Strany 92

AOC-USASLP-L8i Add-on Card User’s Manual8-10Notes

Strany 93 - DISPLAY Command

9-1Chapter 9Using the CFGGEN IR Configuration UtilityThis Chapter describes how to use the CFGGEN IR Configuration Utility to create Integrated Mirror

Strany 94

1-1Chapter 1Safety GuidelinesTo avoid personal injury and property damage, carefully follow all the safety steps listed below when accessing or handli

Strany 95

AOC-USASLP-L8i Add-on Card User’s Manual9-2• WinPE – CFGGEN runs in Windows Pre-Installation Environment (WinPE) and is statically compiled with the L

Strany 96 - FORMAT Command

9-3Chapter 9: Using the CFGGEN IR Configuration Utility• Text surrounded by <> must be replaced with a required parameter.• Text surrounded by [

Strany 97 - STATUS Command

AOC-USASLP-L8i Add-on Card User’s Manual9-4The following rules must be observed when creating IM, IME, and IS volumes and hot spare disks:1. All disks

Strany 98 - SETOFFLINE Command

9-5Chapter 9: Using the CFGGEN IR Configuration UtilityDEFAULTS CommandThe DEFAULTS (DELETE) command deletes any IM, IME, and IS volumes and hot spare

Strany 99 - SETONLINE Command

AOC-USASLP-L8i Add-on Card User’s Manual9-6Program Return Value –0x00 SUCCESS: command completed successfully.0x01 FAILURE: bad command line arguments

Strany 100

9-7Chapter 9: Using the CFGGEN IR Configuration UtilityManufacturer : MAXTORModel Number : ATLAS15K2_036SASFirmware Revision : BG31Serial No : E204

Strany 101

AOC-USASLP-L8i Add-on Card User’s Manual9-8• Inactive, Okay (OKY) – Volume is inactive and drives are functioning properly. User data is protected if

Strany 102

9-9Chapter 9: Using the CFGGEN IR Configuration Utility• noprompt – Suppresses display of warnings and prompts.Program Return Value –0x00 SUCCESS: com

Strany 103 - Disclaimer

AOC-USASLP-L8i Add-on Card User’s Manual9-10Parameters –• <controller #> – Number of the SAS controller targeted by this command.Program Return

Strany 104

9-11Chapter 9: Using the CFGGEN IR Configuration UtilityThe SETOFFLINE command makes a physical disk in a volume offline. A physical disk that is take

Komentáře k této Příručce

Žádné komentáře