A+ SERVER 1022G-URF SUPER®USER’S MANUALRevision 1.0b
xA+ SERVER 1022G-URF User's ManualAppendix B Installing Windows B-1 Installing the Windows OS for a RAID System ...
Chapter 1 Introduction1-1 OverviewThe A+ SERVER 1022G-URF is a high-end server comprised of two main subsystems: the SC815TQ-R700UB 1U server chassis
1-2A+ SERVER 1022G-URF User's Manual1-2 Serverboard FeaturesAt the heart of the A+ SERVER 1022G-URF lies the H8DGU-F, a dual processor serverboar
1-3Chapter 1: IntroductionGraphics ControllerThe H8DGU-F features an integrated Matrox G200eW graphics chip, which includes 16 MB of DDR2 memory.Other
1-4A+ SERVER 1022G-URF User's ManualFront Control PanelThe chassis' control panel provides you with system monitoring and control. LEDs indi
1-5Chapter 1: IntroductionFigure 1-1. AMD SR5670/SP5100 Chipset: System Block DiagramNote: This is a general block diagram. Please see Chapter 5 for d
1-6A+ SERVER 1022G-URF User's Manual1-4 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131 U.S
Chapter 2: Server Installation2-1Chapter 2Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get your A+ SERVER 1022G-URF
2-2A+ SERVER 1022G-URF User's Manual!!Warnings and Precautions!Choosing a Setup LocationLeave enough clearance in front of the rack to enable you
Chapter 2: Server Installation2-3Allow the hot plug SATA drives and power supply modules to cool before touch-• ing them.Always keep the rack's f
The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccu
2-4A+ SERVER 1022G-URF User's Manual2-4 Installing the System into a RackThis section provides information on installing the 1022G-URF into a ra
Chapter 2: Server Installation2-5Installing the Outer RailsBegin by measuring the distance from the front rail to the rear rail of the rack. Attach a
2-6A+ SERVER 1022G-URF User's ManualFigure 2-3. Installing the Server into a RackInstalling the Server into the RackYou should now have rails att
Chapter 2: Server Installation2-7Figure 2-4. Installing the Server into a Telco RackInstalling the Server into a Telco RackTo install the 1022G-URF in
2-8A+ SERVER 1022G-URF User's Manual2-5 Checking the Serverboard SetupAfter you install the 1022G-URF in the rack, you will need to open the top
Chapter 2: Server Installation2-9Figure 2-5. Accessing the Inside of the System2-6 Checking the Drive Bay SetupNext, you should check to make sure th
2-10A+ SERVER 1022G-URF User's ManualChecking the Airfl owAirfl ow is provided by four sets of 4-cm fans (each set of fans consists of 1. two fans
Chapter 3: System Interface3-1Chapter 3 System Interface3-1 OverviewThere are several LEDs on the control panel as well as others on the SAS/SATA driv
3-2A+ SERVER 1022G-URF User's ManualPowerThe main power button is used to apply or remove power from the power supply to the server system. Turni
Chapter 3: System Interface3-3NIC2Indicates network activity on LAN2 when fl ashing.21Note: deactivating the UID LED must be performed in the same way
PrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the installation an
3-4A+ SERVER 1022G-URF User's Manual3-4 Hard Drive Carrier LEDsEach hard drive carrier has two LEDs.Green:• When illuminated, the green LED o
Chapter 4: System Safety4-1Chapter 4 System Safety4-1 Electrical Safety Precautions!Basic electrical safety precautions should be followed to protect
4-2A+ SERVER 1022G-URF User's ManualThe power supply power cords must include a grounding plug and must be • plugged into grounded electrical out
Chapter 4: System Safety4-3While working on the system, do not wear loose clothing such as neckties and • unbuttoned shirt sleeves, which can come int
4-4A+ SERVER 1022G-URF User's ManualFor grounding purposes, make sure your computer chassis provides excellent • conductivity between the power s
Chapter 5: Advanced Serverboard Setup5-1Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to install processors and heatsinks
5-2A+ SERVER 1022G-URF User's Manual5-2 Processor and Heatsink InstallationIMPORTANT! Always connect the power cord last and remove it fi rst be
Chapter 5: Advanced Serverboard Setup5-3TriangleUse your thumb and your index fi nger 3. to hold the CPU. Locate and align pin 1 of the CPU socket with
5-4A+ SERVER 1022G-URF User's ManualInstalling a Passive CPU HeatsinkDo not apply any thermal grease to the heatsink or the CPU die -- the 1. req
Chapter 5: Advanced Serverboard Setup5-55-3 Connecting CablesNow that the processors are installed, the next step is to connect the cables to the serv
A+ SERVER 1022G-URF User's Manualivto this chapter when adding or removing processors or main memory and when reconfi guring the serverboard.Chapt
5-6A+ SERVER 1022G-URF User's ManualFigure 5-1. Front Control Panel Header Pins (JF1)See the Connector Defi nitions section in this chapter for de
Chapter 5: Advanced Serverboard Setup5-75-5 Installing MemoryFigure 5-3. Installing DIMM into Slot!CAUTION! Exercise extreme care when installing or r
5-8A+ SERVER 1022G-URF User's ManualMemory Population for Optimal Performance-For a Motherboard with One CPU (CPU1) Installed# DIMMS CPU Branch 0
Chapter 5: Advanced Serverboard Setup5-9Possible System Memory Allocation & AvailabilitySystem Device Size Physical Memory Available (4 GB Total S
5-10A+ SERVER 1022G-URF User's Manual5-6 Adding PCI CardsPCI Expansion SlotsA riser card is used to support a left side add-on card to the syste
Chapter 5: Advanced Serverboard Setup5-11Figure 5-4. SUPER H8DGU-F Layout(not drawn to scale)5-7 Serverboard DetailsJD1JPW1JF1JI2C1JI2C2JOH1JL1JWF1JPL
5-12A+ SERVER 1022G-URF User's ManualH8DGU(-F) Quick ReferenceJumper Description Default SettingJBT1 CMOS Clear (See Section 2-7)JI2C1/JI2C2 I2C
Chapter 5: Advanced Serverboard Setup5-135-8 Connector Defi nitions Power Connectors A 24-pin main power supply connector(JPW1) and three 8-pin CPU PW
5-14A+ SERVER 1022G-URF User's ManualOverheat/Fan Fail LED (OH)Connect an LED to the OH connection on pins 7 and 8 of JF1 to provide advanced war
Chapter 5: Advanced Serverboard Setup5-15Universal Serial Bus PortsTwo Universal Serial Bus ports (USB 2.0) are located beside the Keyboard and Mouse
vPrefaceNotes
5-16A+ SERVER 1022G-URF User's ManualT-SGPIOThe T-SGPIO1/ T-SGPIO2 (Serial General Purpose Input/Output) headers provide a bus between the SATA c
Chapter 5: Advanced Serverboard Setup5-17ATX PS/2 Keyboard and PS/2 Mouse PortsThe ATX PS/2 keyboard and PS/2 mouse are located next to the Back Panel
5-18A+ SERVER 1022G-URF User's ManualUID ButtonPin Defi nitionsPin# Defi nition1 Ground2 Ground3 Button In4 GroundUnit Identifi er ButtonIn addit
Chapter 5: Advanced Serverboard Setup5-195-9 Jumper SettingsExplanation of JumpersTo modify the operation of the motherboard, jumpers can be used to c
5-20A+ SERVER 1022G-URF User's ManualVGA Enable/DisableJPG1 allows you to enable or disable the VGA port. The default position is on pins 1 and 2
Chapter 5: Advanced Serverboard Setup5-215-10 Onboard IndicatorsLAN1/LAN2 LEDsThe Ethernet ports (located beside the VGA port) have two LEDs. On each
5-22A+ SERVER 1022G-URF User's Manual5-11 SATA Drive ConnectionsSATA PortsThere are no jumpers to confi gure the SATA ports, which are designated
Chapter 5: Advanced Serverboard Setup5-235-12 Enabling SATA RAIDNow that the hardware is set up, you must install the operating system and the SATA R
5-24A+ SERVER 1022G-URF User's ManualFigure 5-5. BIOS Setup ScreenNote: You need to have an external USB fl oppy when building the driver diskette
Chapter 5: Advanced Serverboard Setup5-25After exiting the BIOS Setup Utility, the system will reboot. When prompted 1. during the startup, press the
viA+ SERVER 1022G-URF User's ManualTable of ContentsChapter 1 Introduction1-1 Overview ...
5-26A+ SERVER 1022G-URF User's ManualHighlight the fi rst "Adaptec RAID" driver shown and press the <Enter> key to 5. install it.
Chapter 5: Advanced Serverboard Setup5-27Supero Doctor IIIThe Supero Doctor III program is a Web base management tool that supports remote management
5-28A+ SERVER 1022G-URF User's ManualNote: Super Doctor III Software Revision 1.0 can be downloaded from our Web Site at: ftp://ftp.supermicro.c
Chapter 5: Advanced Serverboard Setup5-29Notes
Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform maintenan
6-2A+ SERVER 1022G-URF User's ManualFigure 6-1. Chassis: Front and Rear Views6-2 Control PanelThe control panel (located on the front of the chas
Chapter 6: Advanced Chassis Setup6-3System Fan FailureFan speed is controlled by system temperature via a BIOS setting. If a fan fails, the remaining
6-4A+ SERVER 1022G-URF User's ManualAccessing the Drive BaysHard Drives: Because of their hotswap capability, you do not need to access the insid
Chapter 6: Advanced Chassis Setup6-5Hard Drive InstallationThe hard drives are mounted in drive carriers to simplify their installation and removal fr
6-6A+ SERVER 1022G-URF User's ManualInstalling/Removing a Hard DriveTo remove a carrier, push the release button located beside the drive LEDs.1.
viiTable of ContentsInstalling the Server into the Rack ... 2-6Installing the Server in
Chapter 6: Advanced Chassis Setup6-7Depress the two buttons on the top of the chassis to release the top cover 2. and at the same time, push the cover
6-8A+ SERVER 1022G-URF User's ManualReplacing the Power SupplyYou do not need to shut down the system to replace a power supply module. The redun
Chapter 7: BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the AMI BIOS Setup Utility for the A+ SERVER 1022G-URF. The AMI ROM BIOS is st
7-2A+ SERVER 1022G-URF User's ManualSystem Time/System Date You can edit this fi eld to change the system time and date. Highlight System Time or
Chapter 7: BIOS7-3Watch Dog FunctionAllows system to restart when system is inactive more than 5-minutes. The options are Enabled and Disabled.Power B
7-4A+ SERVER 1022G-URF User's ManualPower CapThis option can decide the highest P-state in the OS. Options include P-state 0 through P-state 4.AC
Chapter 7: BIOS7-5Bank Swizzle ModeThis setting Enables or Disables the bank swizzle mode. ECC Confi gurationECC ModeThis submenu affects the DRAM scr
7-6A+ SERVER 1022G-URF User's ManualLegacy USB SupportSelect "Enabled" to enable the support for USB Legacy. Disable Legacy support if
Chapter 7: BIOS7-7PIO ModePIO (Programmable I/O) mode programs timing cycles between the IDE drive and the programmable IDE controller. As the PIO mod
7-8A+ SERVER 1022G-URF User's Manual PCI/PnP Confi gurationClear NVRAMSelect Yes to clear NVRAM during boot-up. The options are Yes and No.Plug &
viiiA+ SERVER 1022G-URF User's Manual5-6 Adding PCI Cards ...
Chapter 7: BIOS7-9 SuperIO Device Confi gurationSerial 1 AddressThis option specifi es the base I/O port address and Interrupt Request address of seria
7-10A+ SERVER 1022G-URF User's ManualRedirection After BIOS POSTOptions are Disable (no redirection after BIOS POST), Boot Loader (redirection du
Chapter 7: BIOS7-11 ACPI Confi gurationPS2 KB/MS WakeupThis setting allows you to Enable or Disable PS2 keyboard and mouse wakeup.ACPI Aware O/SThis s
7-12A+ SERVER 1022G-URF User's ManualIP Address SourceSelect the source of this machine's IP address. If Static is selected, you will need t
Chapter 7: BIOS7-13 Event Log Confi gurationView Event LogPressing the Enter key will open the event log. Use the "" and "" keys
7-14A+ SERVER 1022G-URF User's Manual7-5 Boot Menu Boot Device PriorityThis feature allows you to prioritize the boot sequence from the list of
Chapter 7: BIOS7-15Load Optimal DefaultsTo set this feature, select Load Optimal Defaults from the Exit menu and press <Enter>. Then Select &quo
7-16A+ SERVER 1022G-URF User's ManualNotes
A-1Appendix A: BIOS Error Beep CodesAppendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the
A-2A+ SERVER 1022G-URF User's ManualNotes
Table of ContentsixDedicated IPMI LAN LEDs ... 5-21UID LED (LE1) ...
Appendix B: Installing WindowsB-1Appendix B Installing Windows After all hardware components have been installed, you must fi rst confi gure Intel South
B-2A+ SERVER 1022G-URF User's ManualFrom the Windows XP/Windows 2003 Setup screen, press the <Enter> key. 9. The XP/2003 Setup will automat
C-1Appendix C: System Specifi cationsAppendix C System Specifi cationsProcessorsDual AMD Opteron 6100 series (Socket G34 type) processorsNote: You must
C-2A+ SERVER 1022G-URF User's ManualServerboardH8DGU-F (Proprietary form factor)Dimensions: 12.28" x 13.05" (312 x 331 mm)ChassisSC815T
C-3Appendix C: System Specifi cationsRegulatory ComplianceElectromagnetic Emissions: FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-3, CISPR 22 Class A
C-4A+ SERVER 1022G-URF User's Manual(continued from front)The products sold by Supermicro are not intended for and will not be used in life suppo
Komentáře k této Příručce