A+ SERVER2042G-TRF2042G-6RF SUPER®USER’S MANUALRevision 1.0c

Strany 2

xNotesA+ SERVER 2042G-TRF/6RF User's Manual

Strany 3 - Manual Organization

Chapter 1 Introduction1-1 OverviewThe A+ SERVER 2042G-TRF/6RF is a high-end server that is comprised of two main subsystems: the SC828TS+-R1400LPBP 2U

Strany 4

1-2A+ SERVER 2042G-TRF/6RF User's Manual1-2 Serverboard FeaturesAt the heart of the A+ SERVER 2042G-TRF/6RF is one H8QG6/i-F quad processor serve

Strany 5

1-3Chapter 1: IntroductionEthernet PortsAn Intel® network controller is integrated into each of the serverboards to support two Gigabit LAN ports (100

Strany 6 - Table of Contents

1-4A+ SERVER 2042G-TRF/6RF User's Manual1-3 Server Chassis FeaturesThe following is a general outline of the main features of the SC828TS+-R1400

Strany 7 - Chapter 4 System Safety

1-5Chapter 1: IntroductionFigure 1-1. AMD SR5690/SP5100 Chipset: System Block DiagramNote: This is a general block diagram. Please see Chapter 5 for d

Strany 8 - Chapter 7 BIOS

1-6A+ SERVER 2042G-TRF/6RF User's Manual1-4 Contacting SupermicroHeadquartersAddress: Super Micro Computer, Inc.980 Rock Ave.San Jose, CA 95131

Strany 9

Chapter 2: Server Installation2-1Chapter 2 Server Installation2-1 OverviewThis chapter provides a quick setup checklist to get your 2042G-TRF/6RF up

Strany 10

2-2A+ SERVER 2042G-TRF/6RF User's ManualChoosing a Setup LocationLeave enough clearance in front of the rack to enable you to open the front door

Strany 11 - Introduction

Chapter 2: Server Installation2-3Allow the hot plug SAS drives and power supply modules to cool before touch-• ing them.Always keep the rack's fr

Strany 12 - 1-2 Serverboard Features

The information in this User’s Manual has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibility for any inaccu

Strany 13

2-4A+ SERVER 2042G-TRF/6RF User's Manual2-4 Installing the System into a RackThis section provides information on installing the 2042G-TRF/6RF i

Strany 14 - 1-3 Server Chassis Features

Chapter 2: Server Installation2-5Figure 2-1. Installing the Server into a RackInstalling the Server into the RackYou should now have rails attached to

Strany 15 - System Block Diagram

2-6A+ SERVER 2042G-TRF/6RF User's Manual2-5 Checking the Serverboard SetupAfter you install the 2042G-TRF/6RF in the rack, you will need to open

Strany 16 - 1-4 Contacting Supermicro

Chapter 2: Server Installation2-72-6 Preparing to Power OnNext, you should check to make sure the peripheral drives and the SAS drives and SAS backpl

Strany 17 - Chapter 2

2-8A+ SERVER 2042G-TRF/6RF User's ManualNotes

Strany 18 - Warnings and Precautions!

Chapter 3: System Interface3-1PowerThe main power button is used to apply or remove power from the power supply to the server system. Turning off syst

Strany 19 - Rack Mounting Considerations

3-2A+ SERVER 2042G-TRF/6RF User's Manual21NIC2Indicates network activity on GLAN2 when fl ashing.3-3 Control Panel LEDsThe control panel located

Strany 20 - Installing the Outer Rails

Chapter 3: System Interface3-33-4 SAS Drive Carrier LEDsEach SAS drive carrier has two LEDs:Green:• When illuminated, the green LED on the front of

Strany 21

3-4A+ SERVER 2042G-TRF/6RF User's ManualNotes

Strany 22

Chapter 4: System Safety4-1Chapter 4 System Safety4-1 Electrical Safety Precautions!Basic electrical safety precautions should be followed to protect

Strany 23 - 2-6 Preparing to Power On

PrefaceAbout This ManualThis manual is written for professional system integrators and PC technicians. It provides information for the installation an

Strany 24

A+ SERVER 2042G-TRF/6RF User's Manual4-2The power supply power cords must include a grounding plug and must be • plugged into grounded electrical

Strany 25 - System Interface

Chapter 4: System Safety4-3While working on the system, do not wear loose clothing such as neckties and • unbuttoned shirt sleeves, which can come int

Strany 26 - 3-3 Control Panel LEDs

A+ SERVER 2042G-TRF/6RF User's Manual4-4For grounding purposes, make sure your computer chassis provides excellent • conductivity between the pow

Strany 27 - 3-4 SAS Drive Carrier LEDs

Chapter 5: Advanced Serverboard Setup5-1Chapter 5 Advanced Serverboard SetupThis chapter covers the steps required to install the H8QG6/i-F serverboar

Strany 28

5-2A+ SERVER 2042G-TRF/6RF User's ManualUnpackingThe serverboard is shipped in antistatic packaging to avoid electrical static discharge. When u

Strany 29 - System Safety

Chapter 5: Advanced Serverboard Setup5-35-3 Connecting CablesNow that the serverboard is installed, the next step is to connect the cables to the boar

Strany 30

5-4A+ SERVER 2042G-TRF/6RF User's Manual5-4 I/O PortsThe I/O ports are color coded in conformance with the PC 99 specifi cation. See Figure 5-2 be

Strany 31 - 4-3 ESD Precautions

Chapter 5: Advanced Serverboard Setup5-55-5 Installing the Processor and Heatsink!Exercise extreme caution when handling and installing the processor

Strany 32 - BATTERY HOLDER

5-6A+ SERVER 2042G-TRF/6RF User's ManualUse your thumb and your index fi nger 3. to hold the CPU. Locate and align pin 1 of the CPU socket with pi

Strany 33 - Advanced Serverboard Setup

Chapter 5: Advanced Serverboard Setup5-7Installing a Passive CPU HeatsinkDo not apply any thermal grease to the heatsink or the CPU die -- the 1. requ

Strany 34 - 5-2 Serverboard Installation

A+ SERVER 2042G-TRF/6RF User's ManualivChapter 5: Advanced Serverboard SetupChapter 5 provides detailed information on the H8QG6/i-F serverboard,

Strany 35 - 5-3 Connecting Cables

5-8A+ SERVER 2042G-TRF/6RF User's Manual5-6 Installing MemoryExercise extreme caution when installing or removing memory modules to prevent any p

Strany 36 - 4. IPMI LAN 9. UID

Chapter 5: Advanced Serverboard Setup5-9Figure 5-4. Installing DIMM into SlotTo Install: Insert module vertically and press down until it snaps into p

Strany 37

5-10A+ SERVER 2042G-TRF/6RF User's ManualDIMM Module Population Confi gurationFor memory to work properly, follow the tables below for memory inst

Strany 38

Chapter 5: Advanced Serverboard Setup5-115-7 Adding PCI Add-On CardsThe 2042G-TRF/6RF can accommodate low-profi le (only) add-on cards installed into

Strany 39 - No. 2 Screw

5-12A+ SERVER 2042G-TRF/6RF User's ManualFigure 5-5. H8QG6/i-F Layout(not drawn to scale)5-8 Serverboard DetailsJIBTN1FAN6FAN5FAN9FAN8FAN7FAN1FAN

Strany 40 - 2-4 Installing Memory

Chapter 5: Advanced Serverboard Setup5-13LED DescriptionLAN Ports LEDs for the LAN Ethernet portsDedicated IPMI LAN LEDs for the dedicated IPMI LAN Et

Strany 41

5-14A+ SERVER 2042G-TRF/6RF User's Manual5-9 Connector Defi nitions Power Connectors A 24-pin main power supply connector(JPW1) and three 8-pin C

Strany 42

Chapter 5: Advanced Serverboard Setup5-15Power LED ConnectorThe Power LED connector is on pins 15 and 16 of JF1. See the table on the right for pin de

Strany 43 - 5-7 Adding PCI Add-On Cards

5-16A+ SERVER 2042G-TRF/6RF User's ManualUniversal Serial Bus PortsTwo Universal Serial Bus ports (USB 2.0) are located beside the Keyboard and M

Strany 44 - 5-8 Serverboard Details

Chapter 5: Advanced Serverboard Setup5-17Wake-On-LANThe Wake-On-LAN header is designated JWOL. See the table on the right for pin defi nitions. You mus

Strany 46 - 5-9 Connector Defi nitions

5-18A+ SERVER 2042G-TRF/6RF User's ManualChassis Intrusion A Chassis Intrusion header is located at JL1. Attach the appropriate cable to inform y

Strany 47

Chapter 5: Advanced Serverboard Setup5-19UID ButtonPin Defi nitionsPin# Defi nition1 Ground2 Ground3 Button In4 GroundUnit Identifi er ButtonThere is

Strany 48

5-20A+ SERVER 2042G-TRF/6RF User's Manual5-10 Jumper SettingsExplanation of JumpersTo modify the operation of the motherboard, jumpers can be use

Strany 49

Chapter 5: Advanced Serverboard Setup5-21VGA Enable/DisableJPG1 allows you to enable or disable the VGA port. The default position is on pins 1 and 2

Strany 50

5-22A+ SERVER 2042G-TRF/6RF User's ManualBackpanel USB Wake-Up Enable (JPUSB1)Jumper SettingsJumper Setting Defi nitionPins 1-2 Enabled (defa

Strany 51 - Pin Defi nitions (JTPM1)

Chapter 5: Advanced Serverboard Setup5-235-11 Onboard IndicatorsLAN1/LAN2 LEDsThe Ethernet ports (located beside the VGA port) have two LEDs. On each

Strany 52 - 5-10 Jumper Settings

5-24A+ SERVER 2042G-TRF/6RF User's Manual5-12 SAS and SATA Drive ConnectionsSATA PortsThere are no jumpers to confi gure the SATA ports, which ar

Strany 53

Chapter 5: Advanced Serverboard Setup5-255-13 Enabling SATA RAIDNow that the hardware is set up, you must install the operating system and the SATA R

Strany 54 - BMC Jumper Enable (JPB1)

5-26A+ SERVER 2042G-TRF/6RF User's ManualFigure 5-6. BIOS Setup ScreenNote: You need to have an external USB fl oppy when building the driver disk

Strany 55 - 5-11 Onboard Indicators

Chapter 5: Advanced Serverboard Setup5-27After exiting the BIOS Setup Utility, the system will reboot. When prompted 4. during the startup, press the

Strany 56

viA+ SERVER 2042G-TRF/6RF User's ManualTable of ContentsChapter 1 Introduction1-1 Overview ...

Strany 57 - 5-13 Enabling SATA RAID

5-28A+ SERVER 2042G-TRF/6RF User's ManualFigure 5-8. Driver/Tool Installation Display Screen5-14 Installing DriversThe CD that came bundled with

Strany 58

Chapter 5: Advanced Serverboard Setup5-29Supero Doctor IIIThe Supero Doctor III program is a Web base management tool that supports remote management

Strany 59

5-30A+ SERVER 2042G-TRF/6RF User's ManualNote: Supero Doctor III Software Revision 1.0 can be downloaded from our Web Site at: ftp://ftp.supermic

Strany 60 - 5-14 Installing Drivers

Chapter 6: Advanced Chassis Setup6-1Chapter 6 Advanced Chassis SetupThis chapter covers the steps required to install components and perform maintenan

Strany 61 - Supero Doctor III

6-2A+ SERVER 2042G-TRF/6RF User's ManualFigure 6-1. Front and Rear Chassis Views6-2 Control PanelThe control panel (located on the front of the c

Strany 62

Chapter 6: Advanced Chassis Setup6-3System Fan FailureFan speed is controlled by system temperature via a BIOS setting. If a fan fails, the remaining

Strany 63 - Advanced Chassis Setup

6-4A+ SERVER 2042G-TRF/6RF User's ManualInstalling a new fanReplace the failed fan with an identical 8-cm, 12 volt fan (available from 1. Supermi

Strany 64 - 6-3 System Fans

Chapter 6: Advanced Chassis Setup6-5The SAS/SATA drive carriers are located in the front of the chassis, making them easily accessible for installatio

Strany 65 - Replacing System Fans

6-6A+ SERVER 2042G-TRF/6RF User's ManualFigure 6-4. Removing a SAS/SATA Drive Carrier!Important: All of the SAS/SATA drive carriers must remain i

Strany 66 - SAS/SATA Drive Installation

Chapter 6: Advanced Chassis Setup6-7SAS/SATA Drive BackplaneThe SAS/SATA drives plug into a backplane that provides power, drive ID and bus terminatio

Strany 67

viiTable of ContentsInstalling the Inner Rails ... 2-4Installing the Out

Strany 68

6-8A+ SERVER 2042G-TRF/6RF User's Manual6-5 Power SupplyThe A+ SERVER 2042G-TRF/6RF has a 1400 watt redundant power supply consisting of two powe

Strany 69 - SAS828TQ

Chapter 6: Advanced Chassis Setup6-9Figure 6-6. Removing a Power Supply Module

Strany 70 - 6-5 Power Supply

6-10A+ SERVER 2042G-TRF/6RF User's ManualNotes

Strany 71

Chapter 7: BIOS7-1Chapter 7 BIOS 7-1 IntroductionThis chapter describes the AMIBIOS™ Setup utility for the H8QG6/i-F serverboard. The AMI ROM BIOS is

Strany 72

7-2A+ SERVER 2042G-TRF/6RF User's Manual7-2 Main MenuWhen you fi rst enter AMI BIOS Setup Utility, you will see the Main Menu screen.You can alway

Strany 73 - Chapter 7

Chapter 7: BIOS7-3is detected, at which point you will need to press the F1 button to re-enter the BIOS setup menu. The options are Enabled and Disabl

Strany 74 - 7-3 Advanced Settings Menu

7-4A+ SERVER 2042G-TRF/6RF User's ManualACPI SRAT TableThis option Enables or Disables the building of the ACPI SRAT Table.CPU DownCore ModeThis

Strany 75

Chapter 7: BIOS7-5ECC Confi gurationECC ModeThis submenu sets the level of ECC protection. Options include Disabled, Basic, Good, Super, Max and User

Strany 76 - Memory Confi guration

7-6A+ SERVER 2042G-TRF/6RF User's ManualLegacy USB SupportSelect "Enabled" to enable the support for USB Legacy. Disable Legacy support

Strany 77 - DRAM Timing Confi guration

Chapter 7: BIOS7-7Use this value if the IDE disk drive support cannot be determined. Select 0 to allow BIOS to use PIO mode 0, which has a data transf

Strany 78 - IDE/SATA Confi guration

viiiA+ SERVER 2042G-TRF/6RF User's ManualDIMM Module Population Confi guration ... 5-105-7 Adding

Strany 79

7-8A+ SERVER 2042G-TRF/6RF User's Manual PCI/PNP Confi gurationClear NVRAMSelect Yes to clear NVRAM during boot-up. The options are Yes and No.Pl

Strany 80 - SuperI/O Confi guration

Chapter 7: BIOS7-9Serial 2 AddressThis option specifi es the base I/O port address and Interrupt Request address of serial port 2. Select "Disable

Strany 81 - Remote Access Confi guration

7-10A+ SERVER 2042G-TRF/6RF User's ManualSredir Memory Display Delay Use this setting to set the delay in seconds to display memory information.

Strany 82 - ACPI Confi guration

Chapter 7: BIOS7-11ACPI APIC SupportDetermines whether to include the ACPI APIC table pointer in the RSDT pointer list. The available options are Enab

Strany 83 - IP Address

7-12A+ SERVER 2042G-TRF/6RF User's ManualMAC Address In the fi eld provided here enter the MAC address in the hex form of xx.xx.xx.xx.xx.xx with

Strany 84 - 7-4 Security Settings Menu

Chapter 7: BIOS7-13Change User PasswordSelect this option and press <Enter> to access the sub menu, and then type in the password. Boot Sector V

Strany 85 - 7-5 Boot Settings Menu

7-14A+ SERVER 2042G-TRF/6RF User's ManualNetwork DrivesThis feature allows you to specify the boot sequence from the list of available network

Strany 86 - 7-6 Exit Menu

A-1Appendix A: BIOS Error Beep CodesAppendix A BIOS Error Beep Codes During the POST (Power-On Self-Test) routines, which are performed each time the

Strany 87 - BIOS Error Beep Codes

A-2A+ SERVER 2042G-TRF/6RF User's ManualNotes

Strany 88

Appendix B: Installing WindowsB-1Appendix B Installing Windows After all hardware components have been installed, you must fi rst confi gure RAID Settin

Strany 89 - Installing Windows

7-5 Boot Settings Menu ... 7-137-6 Exit Menu ...

Strany 90

B-2A+ Server 2042G-TRF/6RF User's ManualFrom the Windows XP/Windows 2003 Setup screen, press the <Enter> key. 9. The XP/2003 Setup will aut

Strany 91 - System Specifi cations

C-1Appendix C: System Specifi cationsAppendix C System Specifi cationsProcessorsQuad AMD Opteron 6100 series (AMD Socket G34 type) processorsNote: pleas

Strany 92

C-2A+ SERVER 2042G-TRF/6RF User's ManualExpansion SlotsSupports the use of two PCI-E x16, one PCI-E x8 (in a x16 slot), one PCI-E x8 or one UIO s

Strany 93 - Regulatory Compliance

C-3Appendix C: System Specifi cationsRegulatory ComplianceElectromagnetic Emissions:FCC Class A, EN 55022 Class A, EN 61000-3-2/-3-3, CISPR 22 Class AE

Strany 94

C-4A+ SERVER 2042G-TRF/6RF User's Manual(continued from front)The products sold by Supermicro are not intended for and will not be used in life s